Human-in-the-loop Sensing and Control for Commercial Building Energy Efficiency and Occupant Comfort

Most of the existing heating, ventilation and air conditioning (HVAC) systems in commercial buildings operate in a conservative manner by assuming maximum occupancy in each room during pre-specified periods of the week, leading to significant energy being wasted as rooms are over-conditioned compared to the actual requirements of the occupants. Though critical, our understanding of occupancy patterns and thermal comfort needs of the occupants in commercial buildings is lacking and it is well known that both of these quantities are stochastic and time-varying, thus requiring sensing solutions to estimate them. This project had the goal of designing, implementing and evaluating a hardware and software solution to ameliorate this challenge. In particular, a depth camera (one whose pixels reveal distance from the camera as opposed to color values) placed on doorways is used to detect entrance and exit events from thermal zones in the building, and thereby estimate their occupancy levels. This information is then fed to a novel control algorithm that can, through interactions with the HVAC system, learn how to provide control inputs that maximize comfort and minimize energy waste. The resulting system represents a significant improvement over existing controllers for commercial HVAC systems and allowed us to improve our understanding of the design of future human-in-the-loop control solutions. For this solution to be feasible, the project had target metrics for its performance and cost. In particular, entrance and exit events for occupants moving about the building would need to be detected with an accuracy higher than 97%; and the resulting control inputs derived from this information would need to lead to approximately 10% energy savings compared to a schedule-based controller. Furthermore, regarding the final hardware design, the project had a target bill of materials (BOM) cost for the sensing solution of less than US$200 per unit while using less than 25W of power on average. All of these target metrics were met or exceeded by our final proposed solution. We performed evaluations by deploying the system in over 20 rooms of different types across 6 commercial buildings in Pittsburgh, PA over the course of three years, and performing targeted controlled experiments to test its performance along the different metrics. The human-in-the-loop control solutions (both hardware and software) developed through this project are expected to lead to significant improvements in the comfort and energy efficiency of HVAC systems used in commercial buildings. The insights we developed through the project pave the way to HVAC systems that can condition interior spaces according to their real-time utilization and the thermal comfort needs of the occupants, thereby reducing energy use. They also open up a new learning-based way of configuring HVAC controllers without having to manually fine-tune them for each building. These innovations can significantly increase the adoption of novel control solutions by the industry and thereby save resources and reduce costs of operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Leveraging Fine-Grained Occupancy Estimation Patterns for Effective HVAC Control

As occupancy sensing technologies become mature, various occupancy sensors are increasingly deployed in commercial buildings for pervasive occupancy monitoring. These sensors provide occupant-count data, which contains rich spatiotemporal information about occupancy patterns. With long-term occupant-count data collected from a commercial building, we design three different predictive models that capture the occupancy dynamics and examine how a model predictive control of the HVAC system benefits from actual occupancy count prediction. Our analysis reveals that mispredictions of occupancy states, especially false positives and false negatives, may introduce inefficient control that leads to energy waste or user discomfort. To address this issue, we take a step further to design an adaptive model predictive controller that minimizes inefficient control actions according to misprediction types and distributions. A comprehensive evaluation is performed in OpenBuild and EnergyPlus simulators to study the effectiveness of the proposed end-to-end control strategy. The evaluation shows that the proposed solution reduces energy consumption by 29.5% while improving the average weighted occupants comfort by 86.7% in Predicted Mean Vote (PMV) over the fixed schedule strategy.

97 MATHEMATICS AND COMPUTING↗