Seasonal performance evaluation of zero-superheat active refrigerant charge control for variable-speed heat pumps

Heat pumps account for a significant portion of electricity consumption in buildings, making their energy efficiency a critical area of research. Control optimization is recognized as an effective approach for enhancing the efficiency of building HVAC systems. Specifically, since the efficiency of heat pumps increases with reduced superheat and the optimal refrigerant charge level varies with operating conditions, zero-superheat active charge control is a promising strategy to maximize the system’s COP. However, due to its complexity, this control strategy remains in the research phase and has only been tested under limited operating conditions. This paper proposes a methodology to evaluate the seasonal performance improvement of zero-superheat active charge control across a full range of heating conditions in buildings. The methodology includes the development of an optimal controller that utilizes an accumulator to store excess refrigerant and manages the active charge level at zero superheat through subcooling control, as well as the creation of a detailed physics-based heat pump model. Targeted a 3-ton variable-speed heat pump with R410A refrigerant, we selected ten U.S. cities representing different climate regions for seasonal performance evaluation. Our simulations indicate that, depending on the climate conditions, the optimal control strategy could achieve energy savings ranging from 5.8 % to 8.0 % over the entire heating season. These results suggest that zero-superheat active charge control, combined with coordinated compressor and fan speeds, could substantially improve the energy efficiency of heat pump systems while maintaining the required heating capacity.

Guo, Fangzhou

Virtual Refrigerant Charge Sensing Method for Next-Generation Refrigerant in Residential Heat Pumps

The charge level of refrigerant in heat pump systems significantly affects their operational performance. Virtual refrigerant charge (VRC) sensing technology has been well-established for traditional refrigerants (HFCs and HCFCs) for its low cost compared to physical sensors. However, other than traditional refrigerants, HFOs are increasingly used in next-generation heat pumps; whether these conventional VRC sensing methods remain applicable for heat pump systems utilizing next-generation refrigerants requires further investigation. To address these issues, this study develops a low-cost VRC sensing method for next-generation refrigerant heat pumps used in residential buildings. The developed algorithm is evaluated by using simulation models to evaluate the accuracy, considering an R454B heat pump with a nominal heating capacity of 51K Btu/hr (14.95 kW) as an example, and compared with those of the two reference VRC sensing algorithms. Though the developed VRC sensing algorithm and the two reference methods can accurately predict the charge level for the R454B heat pump system (with mean absolute percentage error for various cooling and heating conditions less than 7%), the developed VRC sensing algorithm uses fewer sensors and improves the overall accuracy for heating conditions by 7.1%, and the accuracy for undercharge cooling conditions 14.2%, compared with a mainstream algorithm. This technology will complement physical leakage detectors, and promote the adoption of next-generation heat pump systems, along with reducing wasted energy and maintenance costs.

Liang, Chenjiyu

Burton-Cabrera-Frank theory for the influence of off-cut direction on the growth of hcp crystals

The precise direction of the off-cut of a vicinal crystal surface determines the azimuth (in-plane angle) of the surface steps and thus their kink density. Here we develop a Burton-Cabrera-Frank (BCF) theory for step-flow crystal growth that includes the effects of step azimuth. We focus on the basal-plane surfaces of hexagonal close-packed (hcp) and related crystal structures, for which surface steps have alternating properties that depend on azimuth. We build on a previous treatment that considered only a single-step azimuth, 𝜙 = 0, that gives alternating steps of pure A and B type. As 𝜙 increases from zero, the density of kinks on the steps increases. For hcp-type crystals, in addition the structural difference between alternating steps decreases, until they become equivalent at 𝜙 = 30°. We consider the azimuth dependence of the step transparency, attachment, and repulsion parameters of the BCF model, including the effects of both geometrically required and thermally generated kinks. Example calculations are presented that demonstrate the overall effect of step azimuth on BCF predictions for step spacings during steady-state growth and for their dynamics during growth transients. Effects of symmetric and asymmetric step-step repulsion are discussed.

Ju, Guangxu

Atomic-scale visualization of defect-induced localized vibrations in GaN

Phonon engineering is crucial for thermal management in GaN-based power devices, where phonon-defect interactions limit performance. However, detecting nanoscale phonon transport constrained by III-nitride defects is challenging due to limited spatial resolution. Here, we used advanced scanning transmission electron microscopy and electron energy loss spectroscopy to examine vibrational modes in a prismatic stacking fault in GaN. By comparing experimental results with ab initio calculations, we identified three types of defect-derived modes: localized defect modes, a confined bulk mode, and a fully extended mode. Additionally, the PSF exhibits a smaller phonon energy gap and lower acoustic sound speeds than defect-free GaN, suggesting reduced thermal conductivity. Our study elucidates the vibrational behavior of a GaN defect via advanced characterization methods and highlights properties that may affect thermal behavior.

36 MATERIALS SCIENCE

A Preliminary Investigation on the Performance of a Dual-Source Heat Pump using both the Air and the Ground

Air source heat pumps (ASHPs) and ground source heat pumps (GSHPs) are the two most common types of electric-driven heat pumps in the marketplace to replace fossil fuel-based heating systems. However, the performance and efficiency of ASHPs depend on the ambient air conditions. Therefore, ASHPs usually are equipped with electric resistance heaters to provide supplemental heating when the ambient temperature is low, and the heating demand is high. The electric resistance heaters could result in high power draws when they are turned on. On the other hand, due to the relatively steady temperature of the ground, GSHPs are more energy efficient than ASHPs when providing space heating and cooling to the buildings. However, the adoption of GSHP is hindered by its high initial cost, mostly due to the cost of drilling boreholes for installing ground heat exchangers (GHE). To solve the above issues, our study investigates the performance of dual-source heat pumps (DSHPs) with respect to that of ASHPs and GSHPs. The DSHP will use ambient air when its temperature is favorable for the efficient operation of the heat pump. When the ambient temperature is too hot or too cold, the ground source will be utilized to retain the high-efficiency operation of the heat pump. Because the cumulative thermal load of the GHE is shared with the ambient air, the size of the GHE could be smaller than those of the conventional GSHPs. The study will model the DSHP and simulate its performance in providing heating and cooling for a typical single-family house in regions with hot, mild, or cold climates. In addition, the required GHE size of the DSHP system will be determined through annual simulations and compared with that of conventional GSHPs.

Anees, Fady

A high efficiency rooftop air conditioning system using multi-speed compressors

This study delineates a meticulous exploration of technologies to enhance the energy efficiency of rooftop air conditioning units, employing the DOE/ORNL heat pump design model for comprehensive engineering design and optimization. A baseline rooftop air conditioning unit, featuring a 13 ton (45.7 kW) cooling capacity and a 17.9 integrated energy efficiency ratio, served as the point of departure for substantive efficiency enhancements. Key modifications included the consolidation of two refrigerant circuits into one, integrating three parallel 2-stage (dual-speed) compressors, fan replacements with high-efficiency substitutes. Notably, a lower global warming potential refrigerant, R452B, was evaluated as a substitute for R-410A, demonstrating better performance in the lab prototype. Further, the achieved measured integrated energy efficiency ratio of 21.4 in the lab prototype surpassed the baseline integrated energy efficiency ratio. Comparative evaluations between R410A and R452B indicated heightened efficiency with the latter, showcasing a lab-demonstrated integrated energy efficiency ratio of 22.4 at the rated capacity of 13.8 ton (48.5 kW) and 23.9 integrated energy efficiency ratio at the rated capacity of 10 ton (35.2 kW). This research underscores the successful development of a rigorous, energy efficient rooftop air conditioning unit prototype with noteworthy environmental and economic implications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Development and Testing of an Advanced Cascaded Thermoelectric Residential Heat Pump

Electricity-driven heat pumps using vapor compression cycle are an energy-efficient solution to replace fossil fuel burning and reduce greenhouse gas emissions for space heating in residential buildings. However, heating capacity and Coefficient of Performance (COP) of heat pumps degrade significantly with increasing temperature difference between ambient and indoor environments. Residents and building owners are hence reluctant to fully embrace electric heat pumps. The use of conventional all-electric heat pumps also causes concern for electric utilities due to an increased winter peak demand arising from the use of supplemental electric resistance heaters. Our research is an attempt to alleviate these concerns by designing and laboratory testing a thermoelectric (TE) heat pump cascaded with a vapor compression cycle to enhance heating capacity and COP. TE modules increase the subcooling in the refrigerant liquid of the vapor compression cycle to enlarge the evaporating capacity and works at an efficiency greater than a conventional electric resistance strip. This results in a simple, affordable, efficient and highly controllable solution to adequately meet space heating needs in dwellings. The laboratory testing of the 3-stage cascaded TE heat pump performed in this research has exhibited a higher heating capacity by above 15%, while maintaining a heating COP of 2.0-3.6 in the ambient temperature range of -18˚C to 8˚C (0˚F to 47 ˚F), which represents more than 60% of winter temperatures observed in US. If successfully commercialized, this technology can advance space-heating electrification by overcoming consumer cost barrier of heat pumps.

Shen, Bo

Multifunctional Heat Pump with Energy Storage Capability

Replacing gas furnaces with heat pumps on a large scale can pose challenges to the electrical grid. It will significantly increase the demand, strain the electrical grid, especially during peak usage times. To ensure that heat pumps contribute to reducing emissions, it's essential to increase the share of renewable energy in the grid. However, the supply of renewable energy is unstable. Large scale of electrification must address the concern of grid resilience to meet necessary heating/cooling demands and shift peak electric load. All these require future heat pumps having energy storage capability. These systems can store excess energy during low-demand periods and release it during high-demand periods, reducing stress on the grid. This paper will introduce an innovative configuration, control, and laboratory investigations of a multifunctional packaged heat pump. In addition to the original indoor and outdoor air coils, the heat pump has a parallel hydronic loop with a brazed plate heat exchanger (BHP). The hydronic loop circulates hot/chilled water to store heating/cooling energy in phase change material (PCM). It is capable of space cooling, space heating, cooling energy storage/defrosting, water heating/heating energy storage with outdoor air source or indoor air source, and cooling/heating energy free discharge. The laboratory studies and breadboard unit are presented. Additionally, building energy simulation demonstrates utility cost reduction potential via charging PCM panels/ceilings during off-peak hours and releasing the energy during peak hours to mitigate the peak power consumption.

Shen, Bo

Residential Integrated Heat Pump to Meet All the Home Comfort Needs

This paper will introduce development and field trial of a residential air-source integrated heat pump for cold climates. The heat pump is multi-functional to meet all the home comfort demands, including space cooling, space heating, domestic water heating. The integrated heat pump is an ideal solution to decarbonize northern homes via providing efficient space heating and water heating to replace natural gas. It uses a three-stage compressor and a single set of heat exchangers and valves to deliver all the functions, and thus achieve cost reduction. We developed an innovative system configuration and related controls to solve typical charge unbalance, accelerate charge migration and smoothen mode transition in integrated heat pumps. Laboratory investigations were conducted for individual modes and verified the control functions. Laboratory tests demonstrated that the unit delivered outstanding performance. It achieved 17.0 SEER (seasonal cooling energy efficiency rating) and 11.0 HSPF (heating seasonal performance factor). In the most efficient mode (combined space cooling and water heating mode), the unit reached a total energy efficiency > 30.0 EER and required only 25 minutes to heat a 50-gallon tank of water. One heat pump prototype is going through a field trial since April, 2023 in Syracuse, New York. The one-year field test results are summarized.

Shen, Bo

“Max-tech FHR”: What is the maximum technically achievable water delivery capacity from a single 120 V plug?

Electrifying water heating will require affordable, direct drop-in replacements for existing gas water heaters that meet consumer expectations for hot water delivery. For many replacement scenarios, affordability requires a replacement option with like-for-like physical product dimensions, and existing consumer expectations presume a large delivery capacity from a small water heater. This work explores the technical potential for hot water delivery capacity for a heat pump water heater (HPWH) powered from a common 120 V plug. Delivery capability in this work is quantified by two metrics: the First Hour Rating (FHR) defined in the Code of Federal Regulations, and a real-world draw profile that resulted in hot water runout during field studies of 120 V HPWHs. The work focuses on the common “tall-and-slim” gas water heater product category, with external product dimensions of 20 inch diameter and 60 inch height. Using a simulation model in DOE/ORNL Heat Pump Design Model, validated by experimental baseline testing of a commercially available 120 V HPWH model, several measures were evaluated to maximize the delivery capacity of a 120 V HPWH. The 120 V HPWH was constrained by 1) external product dimensions of 20 in diameter and 60 inch height, 2) electrical power of 1.5 kW (85% of the available power from a dedicated 120 V, 15 A circuit), and 3) commercially-available components. The measures implemented included a large compressor, a pumped loop with plate heat exchanger to maximize tank stratification, enlarged heat exchangers, and relatively thin insulation to maximize the water storage volume.

Gluesenkamp, Kyle

Unlocking the potential of biogas systems for energy production and climate solutions in rural communities

On-site conversion of organic waste into biogas to satisfy consumer energy demand has the potential to realize energy equality and mitigate climate change reliably. However, existing methods ignore either real-time full supply or methane escape when supply and demand are mismatched. Here, we show an improved design of community biogas production and distribution system to overcome these and achieve full co-benefits in developing economies. We take five existing systems as empirical examples. Mechanisms of synergistic adjusting out-of-step biogas flow rates on both the plant-side and user-side are defined to obtain consumption-to-production ratios of close to 1, such that biogas demand of rural inhabitants can be met. Furthermore, carbon mitigation and its viability under universal prevailing climates are illustrated. Coupled with manure management optimization, Chinese national deployment of the proposed system would contribute a 3.77% reduction towards meeting its global 1.5 °C target. Additionally, fulfilling others’ energy demands has considerable decarbonization potential.

09 BIOMASS FUELS

Experimental Investigation on Heating Performance of a Cold Climate Thermoelectric-Assisted Heat Pump

To accelerate the electrification of air source heat pumps (ASHPs) in cold climates across the United States, various initiatives have been launched to enhance the effectiveness of ASHPs. One avenue of research involves incorporating thermoelectric (TE) technology into vapor compression refrigeration cycles. This study aims to assess the heating performance of a cold climate ASHP by employing TE modules as a liquid line subcooler. The tested system is a nominal 4.5-ton split heat pump utilizing R410A, equipped with a scroll compressor and an accumulator. An electronic expansion valve was employed for both cooling and heating modes. Two configurations of TE sub-coolers, one utilizing 2 TE bundles and the other 4 TE bundles, were integrated into the liquid line of the tested system. The heating performance of these configurations was evaluated. The results revealed that activating the TE subcooler led to a notable increase in total heat capacity, reaching 1318 W at -15.0 °C and 1164 W at -19.0 °C. The corresponding TE coefficients of performance (COPs) were 1.76 and 1.63, respectively. The activation of the TE sub-cooler resulted in a slight reduction in the overall system COP, with a decrease ranging from -2.6% to -4.2% for these two temperatures. The system COPs were measured at 2.10 and 1.86 for -15.0 °C and -19.0 °C, respectively. This prototype demonstrated a significant augmentation in heating capacity with a minimal sacrifice in COP.

Hu, Yifeng

Experimental Investigation on Cooling performance of A Thermoelectric Freezer

Thermoelectric heat pumps (TEHPs) have found widespread use in the electronics cooling industry and portable refrigerators. However, there has been a lack of extensive research on the application of TEHPs in low-temperature refrigeration settings. To address this gap, various configurations of TEHPs were fabricated to assess their suitability for freezer applications. Key parameters such as cooling capacity and system performance of the TEHPs were crucial in evaluating these configurations. Three configurations, each with different numbers of cooling units and fan arrangements, were tested using a 300-liter freezer prototype under typical room conditions (21°C). A cooling unit is comprised of two-stage thermoelectric modules, an aluminum plate fin heat exchanger sink with fans positioned either on top or directing airflow through the center, and a cooling block with circulating icy water for heat dissipation. Across all configurations, the minimum temperature inside the freezer cabinet reached -16.0°C. The cooling capacity peaked at 74.7 W, with the thermoelectric coefficient of performance (COP) reaching a maximum of 0.45. System COP ranged from 0.23 to 0.28. Minimum TE power consumption was recorded at 138.8 W, with TE system power consumption at 174.4 W, indicating feasibility for practical residential freezer applications. This investigation lays the foundation for integrating TE freezers with ice thermal storage systems.

Hu, Yifeng

Performance Evaluation of Various Configurations for Domestic Refrigerators with R600a

The increasing global focus on mitigating global warming has driven a change in refrigerant selection for domestic refrigerators. While most existing refrigerators use R-134a as their working fluid, there is a gradual shift towards R600a in newly manufactured products to minimize environmental impact. In order to design a more energy-efficient isobutane refrigerator, various configurations, including both single-evaporator and dual-evaporator cycles, were investigated. The study was conducted using a high-fidelity simulation platform, the Heat Pump Design Model (HPDM), developed and experimentally validated by the US DOE/ORNL. This platform includes detailed segment-to-segment heat exchanger model, fan model, and compressor model, utilizing refrigerant properties from REFPROP 10. A quasi-steady-state approach was employed to simulate the transient behavior and performance of a domestic refrigerator. The performance of various configurations was compared, and the effects of the refrigerant properties and operating conditions were also analyzed and discussed.

Yang, Cheng-Min

System Modeling of Frost/Defrost Cycles in Heat Pumps

Accurately modeling frost/defrost cycles is crucial for guiding heat exchanger design, appropriately sizing the compressor, and quantifying seasonal energy consumption for heating. While previous modelling studies of frosting cycle have predominantly focused on the component level of fin-and-tube coils, there has been limited development of models for system defrosting cycles. This study enhances the existing knowledge by improving a detailed, segment-to-segment heat exchanger model to simulate frost/defrost cycles for both fin-and-tube coils and microchannel heat exchangers. Furthermore, it integrates this component-level model into a steady-state/quasi-steady-state system modeling framework to simulate complete frost/defrost processes, i.e. the ORNL Heat Pump Design Model (HPDM). This comprehensive approach will unveil differences in coil types, and their interactions with the outdoor fan. It will also predict energy consumption patterns and time intervals associated with these processes.