Search NASA⌕ Search

Engineering topics

Shenye, Liu

Publications and source records attributed to Shenye, Liu.

L- and M-shell absorption measurements of radiatively heated Fe plasma

Measurements of iron-plasma absorption spectrum over 150-1200 eV photon energy range were reported at temperature T = (72 {+-} 4) eV. The electron temperature was diagnosed with the absorption spectrum of aluminum mixed with iron. The density was not diagnosed directly but obtained from a radiative hydrodynamic simulation with the Multi-1D code. The broad photon energy range enables simultaneous observation of the L-shell and M-shell transitions that dominate the radiation transport at this temperature. The spectrally resolved transmission data were compared to the detailed-configuration-accounting model calculations and reasonable agreement was found.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interaction of 0.53 {mu}m laser pulse with millimeter-scale plasmas generated by gasbag target

Detailed research on the interaction of a 0.53 {mu}m laser pulse with millimeter-scale plasmas produced by a gasbag target on the Shengguang-II facility is presented. The x-ray pinhole images confirm that millimeter-scale plasmas are generated and the x-ray framing images show a temporal window of 0.6-1.1 ns during which the millimeter-scale plasmas exist. The electron temperature is measured with a collective Thomson scattering system, providing 0.64 keV for C{sub 5}H{sub 12} and 1.8 keV for Xe plasmas. The electron density is inferred from the stimulated Raman scattering spectra. The experimental spectra show large differences for C{sub 5}H{sub 12}- and Xe-filled gasbags. A one-dimensional code based upon steady-state, kinetic linear theory is applied to calculate the stimulated Raman scattering spectra. Excellent agreement between the calculated and experimental results shows that the plasma parameters, especially the electron density and the temperature, dominate the disruption behavior of stimulated Raman scattering. The results also indicate that stimulated Raman scattering is probably located within specific region of the gasbag. The time-integrated reflectivity of both the stimulated Raman and Brillouin scattering is at a low level, even in the conditions of high laser intensity (1.5 Multiplication-Sign 10{sup 15} W/cm{sup 2}) and no beam-smoothing. The experimental results are promising for future ignition experiments with a 0.53 {mu}m laser as the driver.

2-METHYLBUTANE↗

A line-imaging velocity interferometer technique for shock diagnostics without x-ray preheat limitation

A study was conducted with a line-imaging velocity interferometer on sandwich targets at the Shen Guang-III prototype laser facility in China, with the goal of eliminating the preheat effect. A sandwich target structure was used to reduce the x-ray preheat limitation (radiation temperature {approx}170 eV) in a radiative drive shock experiment. With a thick ablator, the preheat effect appeared before the shock arrived at the window. After adding a shield layer of high-Z material on the ablator, x-rays which penetrated the ablator were so weak that the blank-out effect could not be measured. This experiment indicates that the sandwich target may provide a valuable technique in experiments such as equation of state and shock timing for inertial confinement fusion studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Continuing improvements on the novel flat-response x-ray detector

This note describes multi-updates of the novel flat-response x-ray detector in fabrication technology, experimental application, and data uncertainty evaluation. Unlike the previous design, the compound filter is combined into one piece through an improved fabrication process that greatly enhanced its self-supporting capability. A method of pinhole-array imaging is introduced into the experimental application process to stop any debris from the hohlraum and to uniformly reduce the radiation flux. The experimental results show that this method works well. Furthermore, a method of uncertainty evaluation of the radiation flux measurement by the novel flat-response x-ray detector has been developed. The influence of the radiation spectrum to the flux measurement is analyzed. The evaluation shows that the relative uncertainty of the radiation flux is about 10% in higher radiation temperature condition (Tr > 150 eV) and 16% in lower radiation temperature condition (Tr < 100 eV).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel flat-response x-ray detector in the photon energy range of 0.1-4 keV

A novel flat-response x-ray detector has been developed for the measurement of radiation flux from a hohlraum. In order to obtain a flat response in the photon energy range of 0.1-4 keV, it is found that both the cathode and the filter of the detector can be made of gold. A further improvement on the compound filter can then largely relax the requirement of the calibration x-ray beam. The calibration of the detector, which is carried out on Beijing Synchrotron Radiation Facility at Institute of High Energy Physics, shows that the detector has a desired flat response in the photon energy range of 0.1-4 keV, with a response flatness smaller than 13%. The detector has been successfully applied in the hohlraum experiment on Shenguang-III prototype laser facility. The radiation temperatures inferred from the detector agree well with those from the diagnostic instrument Dante installed at the same azimuth angle from the hohlraum axis, demonstrating the feasibility of the detector.

43 PARTICLE ACCELERATORS↗

Quantum-dot-array diffraction grating with single order diffraction property for soft x-ray region

A gold transmission grating is used routinely to disperse the x-ray spectrum at the Z soft x-ray facility to measure the spectrum and temporal history of the absolute soft x-ray power emitted from z-pinch and hohlraum radiation sources. A quantum-dot-array diffraction grating (QDADG) of 250 lines/mm for soft x-ray is designed and fabricated for the first time according to the principle of binary sinusoidal transmission grating. The diffraction efficiencies of the grating are measured in the 150-300 eV photon energy range on the Beamline 3W1B of Beijing Synchrotron Radiation Facility. This article describes the basic concept and calibration techniques and presents calibration results. It is shown that the 250 lines/mm QDADG can be used to disperse light without higher-order diffractions in soft x-ray range, and the diffraction efficiencies of this grating are nearly constant (about 25%), which is beneficial in the spectrum analysis.

43 PARTICLE ACCELERATORS↗

Experimental study of the hydrodynamic trajectory of an x-ray-heated gold plasma

Hydrodynamic processes of radiation-ablated high-Z plasmas have great influence on the x-ray radiation transport both in a high-Z tube with low-Z foam filling and in a low-Z filling indirect drive cavity. Using the intense x-ray radiation to heat a low-Z foam-tamped high-Z gold plate from a half cavity, the hydrodynamic moving process of the x-ray-ablated gold plasma has been studied by an imaging method with Ti He-alpha line emission as the backlighter source. The hydrodynamic trajectory of the x-ray-heated gold plasma was obtained and the average trajectory velocity of (36.5+-1.2) km/s was derived. The experimental trajectory was compared with the simulations using the one-dimensional (1D) RDMG [P. Gu et al., Sci. China, Ser. G 48, 345 (2005)] and two-dimensional (2D) LARED-R [K. Lan et al., Laser Part. Beams 23, 275 (2005)] codes separately. It is shown that the 2D LARED-R code simulated the measured plasma trajectory much better than the 1D RDMG code due to the fact that the lateral x-ray radiation loss was taken into account in the 2D LARED-R but not in the 1D RDMG simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characteristic measurements of silicon dioxide aerogel plasmas generated in a Planckian radiation environment

The temporally and spatially resolved characteristics of silicon dioxide aerogel plasmas were studied using x-ray spectroscopy. The plasma was generated in the near-Planckian radiation environment within gold hohlraum targets irradiated by laser pulses with a total energy of 2.4 kJ in 1 ns. The contributions of silicon ions at different charge states to the specific components of the measured absorption spectra were also investigated. It was found that each main feature in the absorption spectra of the measured silicon dioxide aerogel plasmas was contributed by two neighboring silicon ionic species.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗