Search NASA⌕ Search

Engineering topics

Shetti, Nagaraj P.

Publications and source records attributed to Shetti, Nagaraj P..

Fundamentals of bio-electrochemical sensing

The utilization of bio-functionalities such as biorecognition or catalysis derived them their name biosensors. Bio-electrochemical sensing is a new discipline that combines the advantages of biological detection and electrochemical transduction. Bio-electrochemical sensors are devices that use biological materials such as enzymes, antibodies, DNA, or cells as receptors to detect target analytes in a variety of samples. Electrodes convert biological interactions into electrical impulses, which can be studied using various electrochemical techniques. Bio-electrochemical sensors have demonstrated significant promise for use in clinical diagnostics, environmental monitoring, food safety, and biotechnology. Biosensors have received numerous applications in recent years because they are fast, simple, and inexpensive for practical applications. In this article, we cover the basic principles, design strategies, immobilization and regeneration techniques, along with the advantages and applications of bio-electrochemical sensors. Finally, this article discusses the rationale for developing electrochemical biosensors in the context of the various bio-receptors that can be applied.

36 MATERIALS SCIENCE↗

ZnO/CuO nanostructures anchored over Ni/Cu tubular films via pulse electrodeposition for photocatalytic and antibacterial applications

In this work, we report the fabrication of Ni and Cu tubular substrates and the synthesis of ZnO/CuO nanocomposite on them through the process of pulse electrodeposition. The systematic variation in CuO incorporation in the ZnO matrix and the processing technique were noticed to affect the structural, optical, photocatalytic, and anti-bacterial properties, which are well in accordance with the Field Emission-Scanning Electron Microscope, X-ray Diffraction, Fourier transform Infrared Spectroscopy and UV-Differential reflectance spectroscopy results. The remediation capabilities of the photocatalytic substrates were assessed through the degradation of methylene blue (MB) dye under solar irradiation. Optimized CuO incorporation within the ZnO nanorods resulted in the degradation of a 20 ppm of MB dye solution within 40 min and a higher concentration of 50 ppm within 95 min. The Ni and Cu electroformed tubes as substrates provided not only a reusable supporting frame but also a large surface-area for the growth of ZnO/CuO nanocomposite. The current study also dealt with the anti-bacterial efficacy of the above-mentioned substrates against E.coli. Hence, the Ni and Cu tubular thin film substrates with nanorods of ZnO/CuO composite were explored for the removal of organic as well as biological contaminants from waste water.

36 MATERIALS SCIENCE↗

Sodium Dodecyl Sulfate–Mediated Graphene Sensor for Electrochemical Detection of the Antibiotic Drug: Ciprofloxacin

The present study involves detecting and determining CIP by a new electrochemical sensor based on graphene (Gr) in the presence of sodium dodecyl sulfate (SDS) employing voltammetric techniques. Surface morphology studies of the sensing material were analyzed using a scanning electron microscope (SEM) and atomic force microscope (AFM). In the electroanalysis of CIP at the developed electrode, an enhanced anodic peak response was recorded, suggesting the electro-oxidation of CIP at the electrode surface. Furthermore, we evaluated the impact of the electrolytic solution, scan rate, accumulation time, and concentration variation on the electrochemical behavior of CIP. The possible electrode mechanism was proposed based on the acquired experimental information. A concentration variation study was performed using differential pulse voltammetry (DPV) in the lower concentration range, and the fabricated electrode achieved a detection limit of 2.9 × 10 -8 M. The proposed sensor detected CIP in pharmaceutical and biological samples. The findings displayed good recovery, with 93.8% for tablet analysis and 93.3% to 98.7% for urine analysis. The stability of a developed electrode was tested by inter- and intraday analysis.

36 MATERIALS SCIENCE↗

Zinc Oxide–Graphene Nanocomposite-Based Sensor for the Electrochemical Determination of Cetirizine

A nanocomposite electrode of graphene (Gr) and zinc oxide (ZnO) nanoparticles was fabricated to study the electrochemical oxidation behavior of an anti-inflammatory drug, i.e., cetirizine (CET). The voltametric response of CET for bare CPE, Gr/CPE, ZnO/CPE, and the ZnO-Gr nanocomposite electrode was studied. The modifier materials were characterized using scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), and X-ray powder diffraction (XRD) to comprehend the surface morphology of the utilized modifiers. The influence of pH, scan rate, and accumulation time on the electrooxidation of CET was examined. It was found that the electrochemical oxidation of CET was diffusion-controlled, in which two protons and two electrons participated. The detection limit was found to be 2.8 × 10 -8 M in a linearity range of 0.05–4.0 µM. Study of excipients was also performed, and it was found that they had negligible interference with the peak potential of CET. The validation and utility of the fabricated nanocomposite sensor material were examined by analyzing clinical and biological samples. Stability testing of the nanocomposite electrode was conducted to assess the reproducibility, determining that the developed biosensor has good stability and high efficiency in producing reproducible results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanostructured ZnO-Based Electrochemical Sensor with Anionic Surfactant for the Electroanalysis of Trimethoprim

In this research, detection of trimethoprim (TMP) was carried out using a nanostructured zinc oxide nanoparticle-modified carbon paste electrode (ZnO/CPE) with an anionic surfactant and sodium dodecyl sulphate (SDS) with the help of voltametric techniques. The electrochemical nature of TMP was studied in 0.2 M pH 3.0 phosphate-buffer solution (PBS). The developed electrode displayed the highest peak current compared to nascent CPE. Effects of variation in different parameters, such as pH, immersion time, scan rate, and concentration, were investigated. The electrode process of TMP was irreversible and diffusion controlled with two electrons transferred. The effective concentration range (8.0 × 10 -7 M–1.0 × 10 -5 M) of TMP was obtained by varying the concentration with a lower limit of detection obtained to be 2.58 × 10 -8 M. In addition, this approach was effectively employed in the detection of TMP in pharmaceutical dosages and samples of urine with the excellent recovery data, suggesting the potency of the developed electrode in clinical and pharmaceutical sample analysis.

36 MATERIALS SCIENCE↗

2D Graphene Sheets as a Sensing Material for the Electroanalysis of Zileuton

Zileuton (ZLT) is an active oral inhibitor of enzyme 5-lipoxygenase, and long-term intake and overdose of ZLT cause adverse effects, leading to critical conditions in patients. This is a well-recognized issue that necessitates a better approach for ZLT sensing. Given the increasing interest in ZLT sensing and the limitations of previous techniques, there is a need for a highly sensitive, robust, and fast operation method that is inexpensive and easy to use. Thus, for the sensitive detection and determination of ZLT, an electrochemical sensor based on graphene was fabricated. Graphene has excellent properties, such as high surface area, low toxicity, conductivity, and electroactive conjugation with biomolecules, making it suitable for sensing. The electrocatalytic property of graphene promotes the redox-coupled reaction of ZLT. Electrochemical investigation of the modifier was carried out by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). An optimization and analysis of the influence of different parameters on the electrochemical behavior of ZLT were carried out using the CV approach. The scan rate study aided in exploring the physicochemical properties of the electrode process, and two electrons with two protons were found to be involved in the electrooxidation of ZLT. The fabricated sensor showed a wide range of linearity with ZLT, from 0.3 µM to 100.0 µM, and the detection limit was evaluated as 0.03 µM under optimized conditions. The analysis of spiked urine samples, with good recovery values for percent RSD, provided support for the efficiency and applicability of the developed electrode.

2D Material↗

An Electrochemical Electrode to Detect Theophylline Based on Copper Oxide Nanoparticles Composited with Graphene Oxide

The electrochemical analysis of theophylline (THP) was investigated by fabricating a carbon paste electrode (CPE) modified with graphene oxide (GO) along with copper oxide (CuO) nanoparticles (CuO-GO/CPE). The impact of electro-kinetic parameters such as the heterogeneous rate constant, the scan rate, the accumulation time, the pH, the transfer coefficient, and the number of electrons and protons transferred into the electro-oxidation mechanism of THP has been studied utilizing electrochemical methods such as cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The differential pulse voltammetry technique was employed to investigate THP in pharmaceutical and biological samples, confirming the limit of detection (LOD) and quantification (LOQ) of the THP. X-ray diffraction (XRD) and scanning electron microscopy (SEM) analysis were performed to characterize the CuO nanoparticles. The CuO-GO/CPE was more sensitive in THP detection because its electrocatalytic characteristics displayed an enhanced peak current in the 0.2 M supporting electrolyte of pH 6.0, proving the excellent sensing functioning of the modified electrode.

36 MATERIALS SCIENCE↗

Direct and Sensitive Electrochemical Evaluation of Pramipexole Using Graphitic Carbon Nitride (gCN) Sensor

Pramipexole (PMXL) belongs to the benzothiazole class of aromatic compounds and is used in treating Parkinson’s disease; however, overdosage leads to some abnormal effects that could trigger severe side effects. Therefore, it demands a sensitive analytical tool for trace level detection. In this work, we successfully developed an electrochemical sensor for the trace level detection of PMXL, using the voltammetric method. For the analysis, graphitic carbon nitride (gCN) was opted and synthesized by using a high-temperature thermal condensation method. The synthesized nanoparticles were employed for surface characterization, using transmission electron microscopy (TEM), X-ray diffraction (XRD), and atomic force microscopy (AFM) techniques. The electrochemical characterization of the material was evaluated by using the electrochemical impedance spectroscopy (EIS) technique to evaluate the solution–electrode interface property. The cyclic voltammetry (CV) behavior of PMXL displayed an anodic peak in the forward scan, indicating that PMXL underwent electrooxidation, and an enhanced detection peak with lower detection potential was achieved for gCN-modified carbon paste electrode (gCN·CPE). The influence of different parameters on the electrochemical behavior was analyzed, revealing the diffusion governing the electrode process with an equal number of hydronium ions and electron involvement. For the fabricated gCN·CPE, good linearity range was noticed from 0.05 to 500 µM, and a lower detection limit (L D ) of 0.012 µM was achieved for the selected concentration range (0.5 to 30 µM). Selectivity of the electrode in PMXL detection was investigated by conducting an interference study, while the tablet sample analysis demonstrates the sensitive and real-time application of the electrode. The good recovery values for the analysis illustrate the efficiency of the electrode for PMXL analysis.

36 MATERIALS SCIENCE↗

Versatile Graphitized Carbon Nanofibers in Energy Applications

Graphitized carbon nanofibers (CNFs) are the allotropic forms of carbon that offer exceptional electrical conductivity, high aspect ratio, large surface-to-volume ratio, flexibility, mechanical robustness, and structural stability. These properties render CNFs as useful materials in energy applications, including water electrocatalysis and electrochemical energy storage devices (EESDs). Graphitized CNFs manifest huge versatility in EESDs and have been employed as electrode materials, as supports for other electrode materials, and conductive additives. This perspective summarizes the production methods, structural aspects, and energy applications of graphitized CNFs. Different design strategies have been employed to produce CNFs with diverse and distinct morphologies and structures. Their fabrication methods, along with precursors and dopants or cocatalysts, impact the overall structural, functional, and topographical properties. Recent developments on the state-of-the-art interests of graphitic CNFs in lithium-ion batteries (LIBs), lithium–sulfur (Li–S) batteries, vanadium redox flow batteries (VRFBs), supercapacitors, and water splitting have explored the many possibilities in energy sectors. Finally, the assembly and functioning of CNFs in water splitting and EESDs as well as primary challenges are discussed in this perspective.

36 MATERIALS SCIENCE↗