Search NASA⌕ Search

Engineering topics

Shi, Fang

Publications and source records attributed to Shi, Fang.

At least 37 records · Page 2

Fabrication of coronagraph masks and laboratory scale star-shade masks: characteristics, defects and performance

NASA WFIRST mission has planned to include a coronagraph instrument to find and characterize exoplanets. Masks are needed to suppress the host star light to better than 10-8 – 10-9 level contrast over a broad bandwidth to enable the coronagraph mission objectives. Such masks for high contrast coronagraphic imaging require various fabrication technologies to meet a wide range of specifications, including precise shapes, micron scale island features, ultra-low reflectivity regions, uniformity, wave front quality, etc. We present the technologies employed at JPL to produce these pupil plane and image plane coronagraph masks, and lab-scale external occulter masks, highlighting accomplishments from the high contrast imaging testbed (HCIT) at JPL and from the high contrast imaging lab (HCIL) at Princeton University. Inherent systematic and random errors in fabrication and their impact on coronagraph performance are discussed with model predictions and measurements.

Casey Wilson, Robert↗

Shaped Pupil Coronagraphy for WFIRST: High-Contrast Broadband Testbed Demonstration

The Shaped Pupil Coronagraph (SPC) is one of the two operating modes of the WFIRST (Wide-Field InfraRed Survey Telescope) coronagraph instrument. The SPC provides starlight suppression in a pair of wedge-shaped regions over an 18 percent bandpass, and is well suited for spectroscopy of known exoplanets. To demonstrate this starlight suppression in the presence of expected on-orbit input wavefront disturbances, we have recently built a dynamic testbed at JPL (Jet Propulsion Lab.) analogous to the WFIRST fight instrument architecture, with both Hybrid Lyot Coronagraph (HLC) and SPC architectures and a Low Order Wavefront Sensing and Control (LOWFS/C) subsystem to apply, sense, and correct dynamic wavefront disturbances. We present our best up-to-date results of the static SPC mode demonstration from the testbed, along with model comparisons and performance under realistic dynamical conditions. HLC results will be reported separately.

Cady, Eric↗

Dynamic Testbed Demonstration of WFIRST Coronagraph Low Order Wavefront Sensing and Control (LOWFS/C)

To maintain the required performance of WFIRST Coronagraph in a realistic space environment, a Low Order Wavefront Sensing and Control (LOWFS/C) subsystem is necessary. The LOWFS/C uses a Zernike wavefront sensor (ZWFS) with the phase shifting disk combined with the starlight rejecting occulting mask. For wavefront error corrections, WFIRST LOWFS/C uses a fast steering mirror (FSM) for line-of-sight (LoS) correction, a focusing mirror for focus drift correction, and one of the two deformable mirrors (DM) for other low order wavefront error (WFE) correction. As a part of technology development and demonstration for WFIRST Coronagraph, a dedicated Occulting Mask Coronagraph (OMC) testbed has been built and commissioned. With its configuration similar to the WFIRST flight coronagraph instrument the OMC testbed consists of two coronagraph modes, Shaped Pupil Coronagraph (SPC) and Hybrid Lyot Coronagraph (HLC), a low order wavefront sensor (LOWFS), and an optical telescope assembly (OTA) simulator which can generate realistic LoS drift and jitter as well as low order wavefront error that would be induced by the WFIRST telescope’s vibration and thermal changes. In this paper, we will introduce the concept of WFIRST LOWFS/C, describe the OMC testbed, and present the testbed results of LOWFS sensor performance. We will also present our recent results from the dynamic coronagraph tests in which we have demonstrated of using LOWFS/C to maintain the coronagraph contrast with the presence of WFIRST-like line-of-sight and low order wavefront disturbances.

Zhou, Hanying↗

Narrowband Rejection of Reaction Wheel and Environmental Disturbances for the WFIRST OMC Testbed

The Wide Field Infrared Survey Telescope (WFIRST) is a NASA observatory with two scientific instruments. The first is the Wide Field Instrument (WFI) designed to perform wide field imaging and surveys of the near infrared (NIR) sky. The second is a coronagraph (CGI) that will enable astronomers to detect and measure properties of planets in other solar systems. The coronagraph requires 0.5 milli-arcsecond (mas) RMS pointing per axis of the line of sight (LOS) to achieve a contrast of 1x10-9. This paper discusses the approach used for achieving this level of pointing performance on the occulting mask coronagraph (OMC) testbed at JPL. This testbed uses a low-order wavefront sensing (LOWFS) camera and fast steering mirror (FSM) to suppress injected LOS jitter and environmental LOS jitter. The injected jitter includes representative broadband spacecraft attitude control system (ACS) LOS motion and tonal LOS jitter caused by the reaction wheel assemblies (RWA). The environmental jitter includes thermal LOS variations and harmonics of the line noise. The LOWFS camera uses high flux from the obscured science target to achieve high rate measurements of the LOS. These measurements are augmented with fictitious RWA tachometer information and an estimate of the line noise frequency. A LOS servo using a combination of feedback and feedforward control is used in the testbed to compensate for all of the disturbance sources and to mitigate jitter caused by in-band camera noise. The feedforward uses a novel robust least mean squares (RLMS) filter algorithm to reject the RWA and line frequency tones. High fidelity models of the sensors, disturbances and actuator are presented in this paper. These models were developed as part of a simulation of the LOS control system. Performance results from the hardware testbed at the Jet Propulsion Laboratory (JPL) are discussed in this paper.

Shields, Joel↗

Low Order Wavefront Sensing and Control for WFIRST Coronagraph

To maintain the required WFIRST Coronagraph starlight suppression performance in a realistic space environment, a low order wavefront sensing and control (LOWFS/C) subsystem is necessary. The LOWFS/C uses the rejected stellar light from coronagraph to sense and suppress the telescope pointing drift and jitter as well as the low order wavefront errors due to changes in thermal loading on the telescope and the rest of the observatory. In this paper we will present an overview of the low order wavefront sensing and control subsystem for the WFIRST Coronagraph and describe the WFIRST Coronagraph LOWFS function, its design, and modeled performance. We will present experimental results on a dedicated LOWFS/C testbed that show that the LOWFS/C subsystem not only can sense pointing errors better than 0.2 mas but has also experimentally demonstrated closed loop pointing error suppression with residuals better than 0.4 mas rms per axis for the vast majority of observatory reaction wheel speeds.

wavefront sensing and control↗

Zernike Wavefront Sensor (ZWFS) Development for Low Order Wavefront Sensing (LOWFS)

ZWFS is known to be photon noise optimal for measuring low order aberrations. Recently, ZWFS was selected as the baseline LOWFS technology on WFIRST for its sensitivity, accuracy, and its ease of integration with the starlight rejection mask. In this paper, we present the development of ZWFS sensor, including the algorithm description, sensitivity analysis, and some early experimental model validation results from a fabricated ZWFS phase mask on a stand-alone LOWFS testbed.

Zernike phase contrast↗

Low order wavefront sensing and control for WFIRST coronagraph

To maintain the required WFIRST Coronagraph starlight suppression performance in a realistic space environment, a low order wavefront sensing and control (LOWFS/C) subsystem is necessary. The LOWFS/C uses the rejected stellar light from coronagraph to sense and suppress the telescope pointing drift and jitter as well as the low order wavefront errors due to changes in thermal loading on the telescope and the rest of the observatory. In this paper we will present an overview of the low order wavefront sensing and control subsystem for the WFIRST Coronagraph and describe the WFIRST Coronagraph LOWFS function, its design, and modeled performance. We will present experimental results on a dedicated LOWFS/C testbed that show that the LOWFS/C subsystem not only can sense pointing errors better than 0.2 mas but has also experimentally demonstrated closed loop pointing error suppression with residuals better than 0.4 mas rms per axis for the vast majority of observatory reaction wheel speeds.

Wilson, Dan↗

Zernike Wavefront Sensor Modeling Development for LOWFS on WFIRST-AFTA

WFIRST-AFTA design makes use of an existing 2.4m telescope for direct imaging of exoplanets. To maintain the high contrast needed for the coronagraph, wavefront error (WFE) of the optical system needs to be continuously sensed and controlled. Low Order Wavefront Sensing (LOWFS) uses the rejected starlight from an immediate focal plane to sense wavefront changes (mostly thermally induced low order WFE) by combining the LOWFS mask (a phase plate located at the small center region with reflective layer) with the starlight rejection masks, i.e. Hybrid Lyot Coronagraph (HLC)'s occulter or Shaped Pupil Coronagraph (SPC)'s field stop. Zernike wavefront sensor (ZWFS) measures phase via the phase-contrast method and is known to be photon noise optimal for measuring low order aberrations. Recently, ZWFS was selected as the baseline LOWFS technology on WFIST/AFTA for its good sensitivity, accuracy, and its easy integration with the starlight rejection mask. In this paper, we review the theory of ZWFS operation, describe the ZWFS algorithm development, and summarize various numerical sensitivity studies on the sensor performance. In the end, the predicted sensor performance on SPC and HLC configurations are presented.

Zernike phase contrast↗

Effect of DM Actuator Errors on the WFIRST/AFTA Coronagraph Contrast Performance

The WFIRST/AFTA 2.4 m space telescope currently under study includes a stellar coronagraph for the imaging and the spectral characterization of extrasolar planets. The coronagraph employs two sequential deformable mirrors (DMs) to compensate for phase and amplitude errors in creating dark holes. DMs are critical elements in high contrast coronagraphs, requiring precision and stability measured in picometers to enable detection of Earth-like exoplanets. Working with a low-order wavefront-sensor the DM that is conjugate to a pupil can also be used to correct low-order wavefront drift during a scientific observation. However, not all actuators in a DM have the same gain. When using such a DM in low-order wavefront sensing and control subsystem, the actuator gain errors introduce high-spatial frequency errors to the DM surface and thus worsen the contrast performance of the coronagraph. We have investigated the effects of actuator gain errors and the actuator command digitization errors on the contrast performance of the coronagraph through modeling and simulations, and will present our results in this paper.

adaptive optics↗