Search NASA⌕ Search

Engineering topics

Shi, Y. J.

Publications and source records attributed to Shi, Y. J..

Parametric dependencies of locked mode thresholds in KSTAR L-mode plasmas

Resonant error fields with toroidal harmonics n = 1 and n = 2 in otherwise axisymmetric tokamak plasmas can drive disruptive locked modes when their strength exceeds a threshold value. This paper presents the sensitivity of error field threshold in global parameters such as line-averaged density and toroidal magnetic field as well as toroidal harmonics dependence in KSTAR L-mode plasmas. The error field threshold for mode-locking increases along with density up to a roll-over density, which coincides well with the linear ohmic confinement (LOC) to saturated ohmic confinement (SOC) density for the studied KSTAR plasmas. As a result, this non-monotonic density correlation of the error field threshold in LOC–SOC can be explained by a modification of existing theoretical scaling in SOC, while plasma rotation can also play an important role in setting the resonant error field threshold.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Overview of the recent experimental research on the J-TEXT tokamak

Recent J-TEXT research has highlighted the significance of the role that non-axisymmetric magnetic perturbations, so called three-dimensional (3D) magnetic perturbation (MP) fields, play in a fundamentally 2D concept, i.e. tokamaks. This paper presents the J-TEXT results achieved over the last two years, especially on the impacts of 3D MP fields on magnetohydrodynamic instabilities, plasma disruptions and plasma turbulence transport. On J-TEXT, the resonant MP (RMP) system, capable of providing either a static or a high frequency (up to 8 kHz) rotating RMP field, has been upgraded by adding a new set of 12 in-vessel saddle coils. The shattered pellet injection system was built in J-TEXT in the spring of 2018. The new capabilities advance J-TEXT to be at the forefront of international magnetic fusion facilities, allowing flexible study of 3D effects and disruption mitigation in a tokamak. The fast rotating RMP field has been successfully applied for avoidance of mode locking and the prevention of plasma disruption. A new control strategy, which applies pulsed RMP to the tearing mode only during the accelerating phase region, was proved by nonlinear numerical modelling to be efficient in accelerating mode rotation and even completely suppresses the mode. Remarkably, the rotating tearing mode was completely suppressed by the electrode biasing. The impacts of 3D magnetic topology on the turbulence has been investigated on J-TEXT. It is found that the fluctuations of electron density, electron temperature and plasma potential can be significantly modulated by the island structure, and a larger fluctuation level appears at the X-point of islands. The suppression of runaway electrons during disruptions is essential to the operation of ITER, and it has been reached by utilizing the 3D magnetic perturbations on J-TEXT. Finally, this may provide an alternative mechanism of runaway suppression for large-scale tokamaks and ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First measurement of the edge charge exchange recombination spectroscopy on EAST tokamak

An edge toroidal charge exchange recombination spectroscopy (eCXRS) diagnostic, based on a heating neutral beam injection (NBI), has been deployed recently on the Experimental Advanced Superconducting Tokamak (EAST). The eCXRS, which aims to measure the plasma ion temperature and toroidal rotation velocity in the edge region simultaneously, is a complement to the exiting core CXRS (cCXRS). Two rows with 32 fiber channels each cover a radial range from ∼2.15 m to ∼2.32 m with a high spatial resolution of ∼5-7 mm. Charge exchange emission of Carbon VI CVI at 529.059 nm induced by the NBI is routinely observed, but can be tuned to any interested wavelength in the spectral range from 400 to 700 nm. Double-slit fiber bundles increase the number of channels, the fibers viewing the same radial position are binned on the CCD detector to improve the signal-to-noise ratio, enabling shorter exposure time down to 5 ms. One channel is connected to a neon lamp, which provides the real-time wavelength calibration on a shot-to-shot basis. In this paper, an overview of the eCXRS diagnostic on EAST is presented and the first results from the 2015 experimental campaign will be shown. Good agreements in ion temperature and toroidal rotation are obtained between the eCXRS and cCXRS systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the electron and ion temperatures by the x-ray imaging crystal spectrometer on joint Texas experimental tokamak

An x-ray imaging crystal spectrometer has been developed on joint Texas experimental tokamak for the measurement of electron and ion temperatures from the K{sub α} spectra of helium-like argon and its satellite lines. A two-dimensional multi-wire proportional counter has been applied to detect the spectra. The electron and ion temperatures have been obtained from the Voigt fitting with the spectra of helium-like argon ions. The profiles of electron and ion temperatures show the dependence on electron density in ohmic plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of helium-like and hydrogen-like argon spectra using double-crystal X-ray spectrometers on EAST

A two-crystal assembly was deployed on the tangential X-ray crystal spectrometer to measure both helium-like and hydrogen-like spectra on EAST. High-quality helium-like and hydrogen-like spectra were observed simultaneously for the first time on one detector for a wide range of plasma parameters. Profiles of line-integrated core ion temperatures inferred from two spectra were consistent. Since tungsten was adopted as the upper divertor material, one tungsten line (W XLIV at 4.017 Å) on the short-wavelength side of the Lyman-α line (Lα1) was identified for typical USN discharges, which was diffracted by a He-like crystal (2d = 4.913 Å). Another possible Fe XXV line (1.85 Å) was observed to be located on the long-wavelength side of resonance line (w), which was diffracted from a H-like crystal (2d = 4.5622 Å) on the second order. Be-like argon lines were also observable that fill the detector space between the He-like and H-like spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved spatial calibration for the CXRS system on EAST

A Charge eXchange Recombination Spectroscopy (CXRS) diagnostic system has been developed to measure profiles of ion temperature and rotation since 2014 on EAST. Several techniques have been developed to improve the spatial calibration of the CXRS diagnostic. The sightline location was obtained by measuring the coordinates of three points on each sightline using an articulated flexible coordinate measuring arm when the vessel was accessible. After vacuum pumping, the effect of pressure change in the vacuum vessel was evaluated by observing the movement of the light spot from back-illuminated sightlines on the first wall using the newly developed articulated inspection arm. In addition, the rotation of the periscope after vacuum pumping was derived by using the Doppler shift of neutral beam emission spectra without magnetic field. Combining these techniques, improved spatial calibration was implemented to provide a complete and accurate description of the EAST CXRS system. Due to the effects of the change of air pressure, a ∼0.4° periscope rotation, yielding a ∼20 mm movement of the major radius of observation positions to the lower field side, was derived. Results of Zeeman splitting of neutral beam emission spectra with magnetic field also showed good agreement with the calibration results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tuning carrier density at complex oxide interface with metallic overlayer

We have systematically investigated the electronic transport properties of the LaAlO{sub 3}/SrTiO{sub 3} interfaces with several different metal capping layers. The sheet carrier density can be tuned in a wide range by the metallic overlayer without changing the carrier mobility. The sheet carrier density variation is found to be linearly dependent on the size of metal work function. This behavior is explained by the mechanism of the charge transfer between the oxide interface and the metal overlayer across the LaAlO{sub 3} layer. Our results confirm the existence of a built-in electric field in LaAlO{sub 3} film with an estimated value of 67.7 eV/Å. Since the metallic overlayer is essential for devices, the present phenomena must be considered for future applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Upgrades of imaging x-ray crystal spectrometers for high-resolution and high-temperature plasma diagnostics on EAST

Upgrade of the imaging X-ray crystal spectrometers continues in order to fulfill the high-performance diagnostics requirements on EAST. For the tangential spectrometer, a new large pixelated two-dimensional detector was deployed on tokamaks for time-resolved X-ray imaging. This vacuum-compatible detector has an area of 83.8 × 325.3 mm{sup 2}, a framing rate over 150 Hz, and water-cooling capability for long-pulse discharges. To effectively extend the temperature limit, a double-crystal assembly was designed to replace the previous single crystals for He-like argon line measurement. The tangential spectrometer employed two crystal slices attached to a common substrate and part of He- and H-like Ar spectra could be recorded on the same detector when crystals were chosen to have similar Bragg angles. This setup cannot only extend the measurable Te up to 10 keV in the core region, but also extend the spatial coverage since He-like argon ions will be present in the outer plasma region. Similarly, crystal slices for He-like iron and argon spectra were adopted on the poloidal spectrometer. Wavelength calibration for absolute rotation velocity measurement will be studied using cadmium characteristic L-shell X-ray lines excited by plasma radiation. A Cd foil is placed before the crystal and can be inserted and retracted for in situ wavelength calibration. The Geant4 code was used to estimate X-ray fluorescence yield and optimize the thickness of the foil.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of the charge exchange recombination spectroscopy and the beam emission spectroscopy on the EAST tokamak

Charge eXchange Recombination Spectroscopy (CXRS) and Beam Emission Spectroscopy (BES) diagnostics based on a heating neutral beam have recently been installed on EAST to provide local measurements of ion temperature, velocity, and density. The system design features common light collection optics for CXRS and BES, background channels for the toroidal views, multi-chord viewing sightlines, and high throughput lens-based spectrometers with good signal to noise ratio for high time resolution measurements. Additionally, two spectrometers each has a tunable grating to observe any wavelength of interest are used for the CXRS and one utilizes a fixed-wavelength grating to achieve higher diffraction efficiency for the BES system. A real-time wavelength correction is implemented to achieve a high-accuracy wavelength calibration. Alignment and calibration are performed. Initial performance test results are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wavelength calibration of x-ray imaging crystal spectrometer on Joint Texas Experimental Tokamak

The wavelength calibration of x-ray imaging crystal spectrometer is a key issue for the measurements of plasma rotation. For the lack of available standard radiation source near 3.95 Å and there is no other diagnostics to measure the core rotation for inter-calibration, an indirect method by using tokamak plasma itself has been applied on joint Texas experimental tokamak. It is found that the core toroidal rotation velocity is not zero during locked mode phase. This is consistent with the observation of small oscillations on soft x-ray signals and electron cyclotron emission during locked-mode phase.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preparations for the motional Stark effect diagnostic on EAST

Measurement and control of the current profile is essential for high performance and steady state operation of Experimental Advanced Superconducting Tokamak (EAST). For this purpose, a conventional Motional Stark Effect (MSE) diagnostics utilizing photoelastic modulators is proposed and investigated. The pilot experiment includes one channel to verify the feasibility of MSE, whose sightline intersects with Neutral Beam Injection at major radius of R = 2.12 m. A beam splitter is adopted for simultaneous measurements of Stark multiplets and their polarization directions. A simplified simulation code was also developed to explore the Stark splitting spectra. Finally, the filter is optimized based on the viewing geometry and neutral beam parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Voltage polarity manipulation of the magnetoresistance sign in organic spin valve devices

The spin transport in organic spin valve (OSV) devices has been systematically investigated by inserting a low work function material Al between ferromagnetic electrode and organic layer. The resistance and current-voltage curve symmetry are dramatically altered as increasing Al thickness, indicating that an electron-unipolar OSV is obtained. Moreover, the magnetoresistance sign depends on the voltage polarity for certain Al thickness. We attribute this phenomenon to the Fermi and the lowest unoccupied molecular orbits energies of the two electrodes responding to the spin injection and detection, respectively. These findings provide a simple approach to control both the carrier type and the spin direction simultaneously.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Upgraded high time-resolved x-ray imaging crystal spectroscopy system for J-TEXT ohmic plasmas

This paper presents the upgraded x-ray imaging crystal spectrometer (XICS) system on Joint Texas Experimental Tokamak (J-TEXT) tokamak and the latest experimental results obtained in last campaign. With 500 Hz frame rate of the new Pilatus detector and 5 cm × 10 cm spherically bent crystal, the XICS system can provide core electron temperature (T{sub e}), core ion temperature (T{sub i}), and plasma toroidal rotation (V{sub Φ}) with a maximum temporal resolution of 2 ms for J-TEXT pure ohmic plasmas. These parameters with high temporal resolution are very useful in tokamak plasma research, especially for rapidly changed physical processes. The experimental results from the upgraded XICS system are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗