Search NASASearch

Engineering topics

Shideler, J. L.

Publications and source records attributed to Shideler, J. L..

At least 19 records

Buckling behavior of Rene 41 tubular panels for a hypersonic aircraft wing

The buckling characteristics of Rene 41 tubular panels for a hypersonic aircraft wing were investigated. The panels were repeatedly tested for buckling characteristics using a hypersonic wing test structure and a universal tension/compression testing machine. The nondestructive buckling tests were carried out under different combined load conditions and in different temperature environments. The force/stiffness technique was used to determine the buckling loads of the panel. In spite of some data scattering, resulting from large extrapolations of the data fitting curve (because of the termination of applied loads at relatively low percentages of the buckling loads), the overall test data correlate fairly well with theoretically predicted buckling interaction curves. Also, the structural efficiency of the tubular panels was found to be slightly higher than that of beaded panels.

Ko, W. L.

Buckling behavior of Rene 41 tubular panels for a hypersonic aircraft wing

The buckling characteristics of Rene 41 tubular panels for a hypersonic aircraft wing were investigated. The panels were repeatedly tested for buckling characteristics using a hypersonic wing test structure and a universal tension/compression testing machine. The nondestructive buckling tests were carried out under different combined load conditions and in different temperature environments. The force/stiffness technique was used to determine the buckling loads of the panels. In spite of some data scattering resulting from large extrapolations of the data-fitting curve (because of the termination of applied loads at relatively low percentages of the buckling loads), the overall test data correlate fairly well with theoretically predicted buckling interaction curves. Also, the structural efficiency of the tubular panels was found to be slightly higher than that of beaded panels.

Ko, W. L.

Verification tests of durable TPS concepts

Titanium multiwall, superalloy honeycomb, and Advanced Carbon-carbon (ACC) multipost Thermal Protection System (TPS) concepts are being developed to provide durable protection for surfaces of future space transportation systems. Verification tests including thermal, vibration, acoustic, water absorption, lightning strike, and aerothermal tests are described. Preliminary results indicate that the three TPS concepts are viable up to a surface temperature in excess of 2300 F.

Shideler, J. L.

Verification tests of durable TPS concepts

Titanium multiwall, superalloy honeycomb, and Advanced Carbon-Carbon (ACC) multipost Thermal Protection System (TPS) concepts are being developed to provide durable protection for surfaces of future space transportation systems. Verification tests including thermal, vibration, acoustic, water absorption, lightning strike, and aerothermal tests are described. Preliminary results indicate that the three TPS concepts are viable up to a surface temperature in excess of 2300 F.

Shideler, J. L.

Evaluation of a non-catalytic coating for metallic TPS

A commercially available ceramic coating was evaluated for application to metallic heat shields for Shuttle-type entry vehicles. Coated Inconel 617 specimens were subjected to thermal shock cycles, surface emittances were measured, and surface equilibrium temperatures were measured for coated and oxidized specimens exposed to an arc-tunnel environment. The coating adhered very well to the metal and appeared to be very non-catalytic.

Pittman, C. M.

Development of Rene 41 honeycomb structure as an integral cryogenic tankage/fuselage concept for future space transportation systems

The status of the structural development of an integral cryogenic-tankage/hot-fuselage concept for future space transportation systems is reviewed. The concept comprises a honeycomb sandwich structure that serves the combined functions of containing the cryogenic fuel, supporting the vehicle loads, and protecting the spacecraft from entry heating. The inner face sheet is exposed to cryogenic temperature of -423 F during boost; the outer face sheet, which is slotted to reduce thermal stress, is exposed to a maximum temperature of 1400 F during a high-altitude gliding entry. Attention is given to the development of a fabrication process for a Rene 41 honeycomb sandwich panel with a core density of less than 1 percent that is consistent with desirable heat treatment processes for high strength.

Shideler, J. L.

Thermal and aerothermal performance of a titanium multiwall thermal protection system

A metallic thermal protection system (TPS) concept the multiwall designed for temperature and pressure at Shuttle body point 3140 where the maximum surface temperature is approximately 811 K was tested to evaluate thermal performance and structural integrity. A two tile model of titanium multiwall and a model consisting of a low temperature reusable surface insulation (LRSI) tiles were exposed to 25 simulated thermal and pressure Shuttle entry missions. The two systems performed the same, and neither system deteriorated during the tests. It is indicated that redesign of the multiwall tiles reduces tile thickness and/or weight. A nine tile model of titanium multiwal was tested for radiant heating and aerothermodynamics. Minor design changes that improve structural integrity without having a significant impact on the thermal protection ability of the titanium multiwall TPS are identified. The capability of a titanium multiwall thermal protection system to protect an aluminum surface during a Shuttle type entry trajectory at locations on the vehicle where the maximum surface temperature is below 811 K is demonstrated.

Avery, D. E.

Multiwall TPS: An emerging concept

The transformation of a titanium multiwall thermal protection system from a conceptual design to a working reality is described. The thermal and structural performance of the basic multiwall concept is analyzed. Radiant heat, wind tunnel, vibration, acoustic, and lightning strike tests are used to verify the performance of multiwall tiles under representative operating conditions. Flat, all titanium multiwall configurations limited to temperature below 810 K are discussed. Curved surface, higher temperature versions of the multiwall are considered. Preliminary mass estimates for advanced multiwall concepts are presented.

Shideler, J. L.

Multiwall TPS - An emerging concept

Research on titanium multiwall used for thermal protection is reviewed. Continuing analytical and experimental studies yielding a fundamental understanding of the thermal and structural performance of the basic multiwall concept are presented noting that central to this understanding is a knowledge of the extensional behavior of the dimpled sheets since the thinner flat sheets will buckle and be relatively ineffective in supporting compressive loads. Results from radiant heating, aerothermal, vibration, acoustic and lightning strike tests are described as part of an effort to verify the performance of multiwall tiles under representative operating conditions. Flight tests of a large array of tiles are also planned as part of an orbiter experiments program. The research effort is being extended from flat all-titanium multiwall configurations limited to temperatures below 810 K to curved surfaces and higher temperature versions. Multi-wall concepts are found to offer the durability of metallic systems and to be mass competitive with the insulation system currently used on the Space Shuttle Orbiter.

Shideler, J. L.

Tests of beaded and tubular structural panels

Two efficient concepts built from curved elements were identified, and a data base for tubular panels was developed. The tubular panel failure modes were understood, and the data base for these panels indicated that their performance can be predicted. The concepts are currently being tested in a realistic builtup structure; 157 room temperature tests and 67 hot tests were made with no structural failures, although all of these tests were not at the design load of the structure.

Shideler, J. L.

Radiative metallic thermal protection systems - A status report

During the early stages of the space shuttle program there were a number of technological uncertainties concerning the applicability of metallic thermal protection systems (TPS) to the multimission environment of the shuttle. To resolve the uncertainties and to advance the state-of-the-art, the NASA-Langley Research Center initiated a broad-based technology program to develop metallic TPS over the temperature range from 810 K to 1590 K. Wind tunnel tests conducted to assess the influence of surface/stream interaction of wavy surfaces on the design of metallic TPS indicate small increases in heat flux and surface drag for flow angles less than 20 deg. Analytical and experimental investigations, recently completed, have significantly improved prediction methods for cyclic creep behavior of TPS components repeatedly exposed to complex mission cycles. Thermal/structural concept optimization studies to minimize mass while maintaining structural integrity have led to advanced designs with unit masses which are competitive with those for shuttle RSI. In addition, the durability and reusability of metallic TPS have been repeatedly demonstrated in tests of full-scale systems. The current state-of-the-art strongly suggests that radiative metallic TPS have come of age.

Bohon, H. L.

Performance of LI-1542 reusable surface insulation system in a hypersonic stream

The thermal and structural performance LI-1542 reusable surface insulation (RSI) tiles was investigated. The test panel was designed to represent part of the surface structure on a space shuttle orbiter fuselage along a 1250 K isotherm. Aerothermal tests were conducted at a free-stream Mach number of 6.6, a total temperature of 1820 K, Reynolds numbers of 2 millon and 5 million per meter, and dynamic pressures of 26 and 65 kPa. The RSI tiles demonstrated good thermal protection and structural integrity. High temperatures were caused by misalinement in tile height, offset the tile longitudinal alinement, and leakage around thermal seals when differential pressure existed across the panel. The damage tolerance of LI-1542 RSI appeared high. The tile coating crazed early in the test program, but this did not effect the tile integrity. Erosion of the tile edges occurred at forward-facing steps and at the ends of longitudinal gaps because of particle impacts and flow shear.

Hunt, L. R.

Aerothermal performance and structural integrity of a Rene 41 thermal protection system at Mach 6.6

A flightweight panel based on a metallic thermal-protection-system concept for hypersonic and reentry vehicles was subjected repeatedly to thermal cycling by quartz-lamp radiant heating using a thermal history representative of a reentry heat pulse and to aerodynamic heating at heating rates required to sustain a surface temperature of 1089 K (1960 R). The panel consisted of a corrugated heat shield and support members of 0.05-cm (0.02-in.) thick Rene 41 of riveted construction and 5.08-cm (2-in.) thick silica fibrous insulation packages covered by Rene 41 foil and inconel screening. All tests were conducted in the Langley 8-foot high-temperature structures tunnel with the heat shield corrugations alined in the stream direction. The panel sustained 5.33 hr of intermittent radiant heating and 6.5 min of intermittent aerodynamic heating of up to 1-min duration for differential pressures up to 6.2 kPa (0.9 psi) with no apparent degradation of thermal or structural integrity, as indicated by temperature distributions and results from load deflection tests and vibration surveys of natural frequencies.

Deveikis, W. D.

Evaluation of bead-stiffened metal panels

Potential weight efficiency for bead-stiffened panels has been demonstrated through fabrication and testing. Theoretically optimum design concepts were identified, and small specimens were tested under combined compression, shear, and bending to determine local buckling failure loads and to verify theory. Large optimized panels were then designed and tested under combined loads. Correlation of test data for large circular tubular panels with theory was conservative and consistent, and indicated reliable and acceptable design theory. Tests of fluted tubular panels indicated general instability failures at loads far below the design values due to nonlinear distortions. Further study of the fluted tubular configuration will be required if its potential weight efficiency is to be attained.

Shideler, J. L.

Advanced beaded and tubular structural panels.

A review is presented of an NASA program to develop light-weight beaded and tubular structural panels which can be applied where beaded external surfaces are acceptable aerodynamically or where primary structure is protected by heat shields. The design shapes were obtained with an optimization computer code which iterates geometric parameters to satisfy strength, stability and weight constraints. Methods of fabricating these new configurations are discussed. Nondestructive testing produced extensive combined compression, shear and bending test data on local buckling specimens and large panels. The optimized design concepts offer 25 to 40% weight savings compared to conventional stiffened sheet construction.

Musgrove, M. D.

Optimum mass-strength analysis for orthotropic ring-stiffened cylinders under axial compression

An analysis was developed to calculate the minimum mass-strength curve for an orthotropic cylinder subjected to axial compressive loading. The analysis, which includes the effects of ring and stringer eccentricities, is in a general form so that various cylinder wall and stiffener geometries can be considered. Several different ring-stiffened orthotropic configurations were studied. The minimum mass-strength curves and the dimensions associated with these curves are presented for (in order of decreasing efficiency) a tubular double bead, a nonsymmetric double bead, a Z-stiffened skin, and a trapezoidal corrugation. A comparison of efficiencies of the configurations shows a tubular element cylinder to be more efficient than a 3-percent core-density honeycomb-sandwich cylinder. It was found that for an optimized Z-stiffened skin, the location of the Z-stiffeners (internal or external) made a negligible difference in efficiency.

Shideler, J. L.