Search NASA⌕ Search

Engineering topics

Shimizu, H

Publications and source records attributed to Shimizu, H.

SU-F-T-494: A Multi-Institutional Study of Independent Dose Verification Using Golden Beam Data

Purpose: In general, beam data of individual linac is measured for independent dose verification software program and the verification is performed as a secondary check. In this study, independent dose verification using golden beam data was compared to that using individual linac’s beam data. Methods: Six institutions were participated and three different beam data were prepared. The one was individual measured data (Original Beam Data, OBD) .The others were generated by all measurements from same linac model (Model-GBD) and all linac models (All-GBD). The three different beam data were registered to the independent verification software program for each institute. Subsequently, patient’s plans in eight sites (brain, head and neck, lung, esophagus, breast, abdomen, pelvis and bone) were analyzed using the verification program to compare doses calculated using the three different beam data. Results: 1116 plans were collected from six institutes. Compared to using the OBD, the results shows the variation using the Model-GBD based calculation and the All-GBD was 0.0 ± 0.3% and 0.0 ± 0.6%, respectively. The maximum variations were 1.2% and 2.3%, respectively. The plans with the variation over 1% shows the reference points were located away from the central axis with/without physical wedge. Conclusion: The confidence limit (2SD) using the Model-GBD and the All-GBD was within 0.6% and 1.2%, respectively. Thus, the use of golden beam data may be feasible for independent verification. In addition to it, the verification using golden beam data provide quality assurance of planning from the view of audit. This research is partially supported by Japan Agency for Medical Research and Development(AMED)

60 APPLIED LIFE SCIENCES↗

SU-E-T-48: A Multi-Institutional Study of Independent Dose Verification for Conventional, SRS and SBRT

Purpose: To show the results of a multi-institutional study of the independent dose verification for conventional, Stereotactic radiosurgery and body radiotherapy (SRS and SBRT) plans based on the action level of AAPM TG-114. Methods: This study was performed at 12 institutions in Japan. To eliminate the bias of independent dose verification program (Indp), all of the institutions used the same CT-based independent dose verification software (Simple MU Analysis, Triangle Products, JP) with the Clarkson-based algorithm. Eclipse (AAA, PBC), Pinnacle{sup 3} (Adaptive Convolve) and Xio (Superposition) were used as treatment planning system (TPS). The confidence limits (CL, Mean±2SD) for 18 sites (head, breast, lung, pelvis, etc.) were evaluated in comparison in dose between the TPS and the Indp. Results: A retrospective analysis of 6352 treatment fields was conducted. The CLs for conventional, SRS and SBRT were 1.0±3.7 %, 2.0±2.5 % and 6.2±4.4 %, respectively. In conventional plans, most of the sites showed within 5 % of TG-114 action level. However, there were the systematic difference (4.0±4.0 % and 2.5±5.8 % for breast and lung, respectively). In SRS plans, our results showed good agreement compared to the action level. In SBRT plans, the discrepancy between the Indp was variable depending on dose calculation algorithms of TPS. Conclusion: The impact of dose calculation algorithms for the TPS and the Indp affects the action level. It is effective to set the site-specific tolerances, especially for the site where inhomogeneous correction can affect dose distribution strongly.

60 APPLIED LIFE SCIENCES↗

ILC Positron Source Based on Laser Compton

Positron generation is one of the most difficult technical challenges among the ILC (International Linear Collider) subsystems. A positron source based on Laser Compton back scattering is an attractive and advanced option for the ILC positron source. Here, the positrons are generated, via the pair creation process, from high energy gamma rays which themselves are produced by Compton scattering of laser photons off a high-energy electron beam. Polarized positrons can be generated by employing a circularly polarized laser. The positron polarization is easily controlled and switched by changing the laser polarity. The electron beam can be unpolarized. The required electron energy is only a few GeV (in contrast, the ''undulator scheme'', another advanced option, requires at least 100 GeV or more) and the system can be prototyped and tested prior to the real construction. The laser Compton technology has many other applications like advanced X-ray sources and a good synergy is expected. In addition, this technology can be a powerful driving force for the ILC project attracting many researchers from outside the ILC community. The ILC positron source is a technical challenge and it will be realized only if the latest technologies are integrated seamlessly with the necessary R and D efforts for system specific issues. The latest technologies include high power lasers, high brightness electron beams, high finesse optical cavities for as laser-beam interaction point, etc. We present the design status and the related experimental efforts for the ILC positron source based on Laser Compton scattering. The respective advantages of various options for the electron beam (based on Linac, storage ring, and ERL) are also compared.

43 PARTICLE ACCELERATORS↗