Search NASA⌕ Search

Engineering topics

Shiraishi, S

Publications and source records attributed to Shiraishi, S.

At least 19 records

MO-G-201-04: Knowledge-Based Planning for Single-Isocenter Stereotactic Radiosurgery to Multiple Brain Metastases

Purpose: Single-isocenter, linac-based SRS for multiple brain metastases (multi-mets) can deliver highly conformal radiation doses and reduce overall patient treatment time compared to other therapy techniques. This study aims to quantify the dosimetric benefits of knowledge-based planning (KBP) for multi-met treatments. Methods: Using a previously-published KBP methodology (an artificial neural network (ANN) trained on single-target linac-based SRS plans), 3D dose distribution predictions for multi-met patients were obtained by treating each brain lesion as a solitary target and subsequently combining individual predictions into a single distribution using a dose-weighted geometric averaging to obtain the best results in the inter-target space. 17 previously-treated multi-met plans, with target numbers ranging from N=2–5, were used to validate the ANN predictions and subsequent KBP auto-planning routine. The fully-deliverable KBP plans were developed by converting dose distribution predictions into patient-specific optimization objectives while maintaining identical target normalizations (typically PTV V100%=D98%). Plan quality improvements were quantified by the difference between SRS quality metrics (QMs): δdQM=QM(clinical)-QM(KBP). QMs of interest were: gradient measure (GM), conformity index (CI), brain V10 and V5, brainstem D0.1cc and heterogeneity index (HI). Finally, overall plan quality was judged via blinded plan comparison by SRS-specializing physicians. Results: Two clinical plans were found to be significant outliers wherein plan quality was dramatically worse than KBP. Despite indicating KBP superiority, these were removed from the QM analysis to prevent skewing the results. In the remaining cases, clinical and KBP QMs were nearly identical with modest improvements in the KBP sample: δGM=0.12±0.56mm, δCI=−0.01±0.04, Brain δV10=0.8±2.6cc, brain δV5=6.3 ±10.7cc, brainstem δD0.1cc=0.06±1.19Gy and δHI= −0.04±0.05. Ultimately, 13/17 KBP plans were deemed superior to the manual plans in blinded physician review. Conclusion: The results demonstrate that KBP-driven automated planning in linac-based single-isocenter treatments for multiple brain metastases is indistinguishable from, or even better than, traditional manual planning. J. Hattangadi: Research Grant; Varian Medical Systems; K.L. Moore: Research Grant: Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

MO-FG-303-03: Demonstration of Universal Knowledge-Based 3D Dose Prediction

Purpose: To demonstrate a knowledge-based 3D dose prediction methodology that can accurately predict achievable radiotherapy distributions. Methods: Using previously treated plans as input, an artificial neural network (ANN) was trained to predict 3D dose distributions based on 14 patient-specific anatomical parameters including the distance (r) to planning target volume (PTV) boundary, organ-at-risk (OAR) boundary distances, and angular position ( θ,φ). 23 prostate and 49 stereotactic radiosurgery (SRS) cases with ≥1 nearby OARs were studied. All were planned with volumetric-modulated arc therapy (VMAT) to prescription doses of 81Gy for prostate and 12–30Gy for SRS. Site-specific ANNs were trained using all prostate 23 plans and using a 24 randomly-selected subset for the SRS model. The remaining 25 SRS plans were used to validate the model. To quantify predictive accuracy, the dose difference between the clinical plan and prediction were calculated on a voxel-by-voxel basis δD(r,θ,φ)=Dclin(r,θ,φ)-Dpred(r, θ,φ). Grouping voxels by boundary distance, the mean <δ Dr>=(1/N)Σ -θ,φ D(r,θ,φ) and inter-quartile range (IQR) quantified the accuracy of this method for deriving DVH estimations. The standard deviation (σ) of δ D quantified the 3D dose prediction error on a voxel-by-voxel basis. Results: The ANNs were highly accurate in predictive ability for both prostate and SRS plans. For prostate, <δDr> ranged from −0.8% to +0.6% (max IQR=3.8%) over r=0–32mm, while 3D dose prediction accuracy averaged from σ=5–8% across the same range. For SRS, from r=0–34mm the training set <δDr> ranged from −3.7% to +1.5% (max IQR=4.4%) while the validation set <δDr> ranged from −2.2% to +5.8% (max IQR=5.3%). 3D dose prediction accuracy averaged σ=2.5% for the training set and σ=4.0% over the same interval. Conclusion: The study demonstrates this technique’s ability to predict achievable 3D dose distributions for VMAT SRS and prostate. Future investigations will attempt to separate and quantify modeling error and plan quality variations in the statistical noise. Research funding support from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

TH-A-9A-08: Knowledge-Based Quality Control of Clinical Stereotactic Radiosurgery Treatment Plans

Purpose: To develop a quality control tool to reduce stereotactic radiosurgery (SRS) planning variability using models that predict achievable plan quality metrics (QMs) based on individual patient anatomy. Methods: Using a knowledge-based methodology that quantitatively correlates anatomical geometric features to resultant organ-at-risk (OAR) dosimetry, we developed models for predicting achievable OAR dose-volume histograms (DVHs) by training with a cohort of previously treated SRS patients. The DVH-based QMs used in this work are the gradient measure, GM=(3/4pi)^1/3*[V50%^1/3−V100%^1/3], and V10Gy of normal brain. As GM quantifies the total rate of dose fall-off around the planning target volume (PTV), all voxels inside the patient's body contour were treated as OAR for DVH prediction. 35 previously treated SRS plans from our institution were collected; all were planned with non-coplanar volumetric-modulated arc therapy to prescription doses of 12–25 Gy. Of the 35-patient cohort, 15 were used for model training and 20 for model validation. Accuracies of the predictions were quantified by the mean and the standard deviation of the difference between clinical and predicted QMs, δQM=QM-clin−QM-pred. Results: Best agreement between predicted and clinical QMs was obtained when models were built separately for V-PTV<2.5cc and V-PTV>2.5cc. Eight patients trained the V-PTV<2.5cc model and seven patients trained the V-PTV>2.5cc models, respectively. The mean and the standard deviation of δGM were 0.3±0.4mm for the training sets and −0.1±0.6mm for the validation sets, demonstrating highly accurate GM predictions. V10Gy predictions were also highly accurate, with δV10Gy=0.8±0.7cc for the training sets and δV10Gy=0.7±1.4cc for the validation sets. Conclusion: The accuracy of the models in predicting two key SRS quality metrics highlights the potential of this technique for quality control for SRS treatments. Future investigations will seek to determine whether QM variations are due to residual model inaccuracies or true plan quality variations in the clinical sample. Support from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Beam transport and monitoring for laser plasma accelerators

The controlled transport and imaging of relativistic electron beams from laser plasma accelerators (LPAs) are critical for their diagnostics and applications. Here we present the design and progress in the implementation of the transport and monitoring system for an undulator based electron beam diagnostic. Miniature permanent-magnet quadrupoles (PMQs) are employed to realize controlled transport of the LPA electron beams, and cavity based electron beam position monitors for non-invasive beam position detection. Also presented is PMQ calibration by using LPA electron beams with broadband energy spectrum. The results show promising performance for both transporting and monitoring. With the proper transport system, XUV-photon spectra from THUNDER will provide the momentum distribution of the electron beam with the resolution above what can be achieved by the magnetic spectrometer currently used in the LOASIS facility.

43 PARTICLE ACCELERATORS↗

Long-range persistence of femtosecond modulations on laser-plasma-accelerated electron beams

Laser plasma accelerators have produced femtosecond electron bunches with a relative energy spread ranging from 100% to a few percent. Simulations indicate that the measured energy spread can be dominated by a correlated spread, with the slice spread significantly lower. Measurements of coherent optical transition radiation are presented for broad-energy-spread beams with laser-induced density and momentum modulations. The long-range (meter-scale) observation of coherent optical transition radiation indicates that the slice energy spread is below the percent level to preserve the modulations.

43 PARTICLE ACCELERATORS↗

Search for R-Parity Violating Decays of Sneutrinos to e{mu}, {mu}{tau}, and e{tau} Pairs in pp Collisions at {radical}(s)=1.96 TeV

We present a search for supersymmetric neutrino {nu}-tilde production using the Tevatron pp collision data collected with the CDF II detector and corresponding to an integrated luminosity of 1 fb{sup -1}. We focus on the scenarios predicted by the R-parity violating (RPV) supersymmetric models in which sneutrinos decay to two charged leptons of different flavor. With the data consistent with the standard model expectations, we set upper limits on {sigma}(pp{yields}{nu}-tilde)xBR({nu}-tilde{yields}e{mu},{mu}{tau},e{tau}) and use these results to constrain the RPV couplings as a function of the sneutrino mass.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Wavefront Measurement for Laser-Guiding Diagnostic

The wavefront of a short laser pulse after interaction in a laser-plasma accelerator (LPA) was measured to diagnose laser-guiding quality. Experiments were performed on a 100 TW class laser at the LOASIS facility of LBNL using a hydrogen-filled capillary discharge waveguide. Laser-guiding with a pre-formed plasma channel allows the laser pulse to propagate over many Rayleigh lengths at high intensity and is crucial to accelerate electrons to the highest possible energy. Efficient coupling of laser energy into the plasma is realized when the laser and the channel satisfy a matched guiding condition, in which the wavefront remains flat within the channel. Using a wavefront sensor, the laser-guiding quality was diagnosed based on the wavefront of the laser pulse exiting the plasma channel. This wavefront diagnostic will contribute to achieving controlled, matched guiding in future experiments.

43 PARTICLE ACCELERATORS↗

Tape-Drive Based Plasma Mirror

We present experimental results on a tape-drive based plasma mirror which could be used for a compact coupling of a laser beam into a staged laser driven electron accelerator. This novel kind of plasma mirror is suitable for high repetition rates and for high number of laser shots.

43 PARTICLE ACCELERATORS↗

Ultrafast Diagnostics for Electron Beams from Laser Plasma Accelerators

We present an overview of diagnostic techniques for measuring key parameters of electron bunches from Laser Plasma Accelerators (LPAs). The diagnostics presented here were chosen because they highlight the unique advantages (e.g. diverse forms of electromagnetic emission) and difficulties (e.g. shot-to-shot variability) associated with LPAs. Non destructiveness and high resolution (in space and time and energy) are key attributes that enable the formation of a comprehensive suite of simultaneous diagnostics which are necessary for the full characterization of the ultrashort, but highly-variable electron bunches from LPAs.

43 PARTICLE ACCELERATORS↗

Transport and Non-Invasive Position Detection of Electron Beams from Laser-Plasma Accelerators

The controlled imaging and transport of ultra-relativistic electrons from laser-plasma accelerators is of crucial importance to further use of these beams, e.g. in high peak-brightness light sources. We present our plans to realize beam transport with miniature permanent quadrupole magnets from the electron source through our THUNDER undulator. Simulation results demonstrate the importance of beam imaging by investigating the generated XUV-photon flux. In addition, first experimental findings of utilizing cavity-based monitors for non-invasive beam-position measurements in a noisy electromagnetic laser-plasma environment are discussed.

43 PARTICLE ACCELERATORS↗

Spectroscopy of betatron radiation emitted from laser-produced wakefield accelerated electrons

X-ray betatron radiation is produced by oscillations of electrons in the intense focusing field of a laser-plasma accelerator. These hard x-rays show promise for use in femtosecond-scale time-resolved radiography of ultrafast processes. However, the spectral characteristics of betatron radiation have only been inferred from filter pack measurements. In order to achieve higher resolution spectral information about the betatron emission, we used an x-ray charge-coupled device to record the spectrum of betatron radiation, with a full width at half maximum resolution of 225 eV. In addition, we have recorded simultaneous electron and x-ray spectra along with x-ray images that allow for a determination of the betatron emission source size, as well as differences in the x-ray spectra as a function of the energy spectrum of accelerated electrons.

43 PARTICLE ACCELERATORS↗

Exclusion of an Exotic Top Quark with -4/3 Electric Charge Using Soft Lepton Tagging

We present a measurement of the electric charge of the top quark using pp collisions corresponding to an integrated luminosity of 2.7 fb{sup -1} at the CDF II detector. We reconstruct tt events in the lepton+jets final state. We use soft lepton taggers to determine the flavor of the b jets, which we use to reconstruct the top quark's electric charge and exclude an exotic top quark with -4/3 charge at 95% confidence level. This is the strongest exclusion of the exotic charge scenario and the first to use soft leptons for this purpose.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for anomalous production of events with two photons and additional energetic objects at CDF

We present results of a search for anomalous production of two photons together with an electron, muon, {tau} lepton, missing transverse energy, or jets using pp collision data from 1.1-2.0 fb{sup -1} of integrated luminosity collected by the Collider Detector at Fermilab (CDF). The event yields and kinematic distributions are examined for signs of new physics without favoring a specific model of new physics. The results are consistent with the standard model expectations. The search employs several new analysis techniques that significantly reduce instrumental backgrounds in channels with an electron and missing transverse energy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for the Production of Scalar Bottom Quarks in pp Collisions at {radical}(s)=1.96 TeV

We report on a search for direct scalar bottom quark (sbottom) pair production in pp collisions at {radical}(s)=1.96 TeV, in events with large missing transverse energy and two jets of hadrons in the final state, where at least one of the jets is required to be identified as originating from a b quark. The study uses a collider detector at Fermilab Run II data sample corresponding to 2.65 fb{sup -1} of integrated luminosity. The data are in agreement with the standard model. In an R-parity conserving minimal supersymmetric scenario, and assuming that the sbottom decays exclusively into a bottom quark and a neutralino, 95% confidence-level upper limits on the sbottom pair production cross section of 0.1 pb are obtained. For neutralino masses below 70 GeV/c{sup 2}, sbottom masses up to 230 GeV/c{sup 2} are excluded at 95% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of Z{gamma} production in pp collisions at {radical}(s)=1.96 TeV

The production rate and kinematics of photons produced in association with Z bosons are studied using 2 fb{sup -1} of pp collision data collected at the Collider Detector at Fermilab. The cross section for pp{yields}l{sup +}l{sup -}{gamma}{sup +}X (where the leptons l are either muons or electrons with dilepton mass M{sub ll}>40 GeV/c{sup 2}, and where the photon has transverse energy E{sub T}{sup {gamma}}>7 GeV and is well separated from the leptons) is 4.6{+-}0.2(stat){+-}0.3(syst){+-}0.3(lum) pb, which is consistent with standard model expectations. We use the photon E{sub T} distribution from Z{gamma} events where the Z has decayed to {mu}{sup +}{mu}{sup -}, e{sup +}e{sup -}, or {nu}{nu} to set limits on anomalous (non standard model) trilinear couplings between photons and Z bosons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Studying the underlying event in Drell-Yan and high transverse momentum jet production at the Tevatron

We study the underlying event in proton-antiproton collisions by examining the behavior of charged particles produced in association with a large transverse momentum jet ({approx}2.2 fb{sup -1}) or with a Drell-Yan lepton pair ({approx}2.7 fb{sup -1}) in the Z-boson mass region [70<M(pair)<110 GeV/c{sup 2}] as measured by CDF at 1.96 TeV center-of-mass energy. We use the direction of the lepton pair or the leading jet in each event to define regions of {eta}-{phi} space that are sensitive to the modeling of the underlying event. The data are corrected to the particle level to remove detector effects and are then compared with several QCD Monte Carlo models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗