Shitzer, A.

Publications and source records attributed to Shitzer, A..

Modular liquid-cooled helmet liner for thermal comfort

A modular liquid-cooled helmet liner made of eight form-fitting neoprene patches was constructed. The liner was integrated into the sweatband of an Army SPH-4 helicopter aircrew helmet. This assembly was tested on four subjects seated in a hot (47 C), humid (40%) environment. Results indicate a marked reduction in the rate of increase of physiological body functions. Rectal temperature, weight loss, heart rate, and strain indices are all reduced to approximately 50% of uncooled levels. The cooling liner removed from 10% to 30% of total metabolic heat produced. This study also demonstrated the technical feasilibity of using a cooling liner in conjunction with a standard hard helmet. Potential applications of the cooling liner in thermally stressful environments are numerous, notably for helicopter and other aircrews.

Williams, B. A.↗

Comparative study of patches for liquid cooled garments.

Tests were performed on 12 cooling patches of various designs to establish criteria for the evaluation of their performance in liquid-cooled suits in industrial, military and aerospace applications. The thermal effectiveness value was 0.088 for patch designs with a double spiral flow pattern, and 0.075 for patch designs with a parallel flow pattern. The ratio of thermal energy transfer rate to cooling-medium pumping power requirement is indicated as the prime performance characteristic to be considered in the selection and rating of cooling patches.

Shitzer, A.↗

Removal of metabolic heat from man working in a protective suit

A water cooled garment was constructed and used to study the characteristics of independent regional cooling of the body in contrast to the current practice of uniform cooling. The cooling pads in the garment were grouped to provide independent control of water inlet temperatures and flow rates to six regions: head, upper torso, lower torso, arms, thighs, and lower legs. Experiments with and without the cooling suit were conducted with five test subjects standing and walking on a treadmill on selected schedules. Steady state and, to a lesser extent, transient characteristics were obtained.

Shitzer, A.↗

Analytical prediction of the heat transfer from a blood vessel near the skin surface when cooled by a symmetrical cooling strip

An analytical method was developed to estimate the amount of heat extracted from an artery running close to the skin surface which is cooled in a symmetrical fashion by a cooling strip. The results indicate that the optimum width of a cooling strip is approximately three times the depth to the centerline of the artery. The heat extracted from an artery with such a strip is about 0.9 w/m-C which is too small to affect significantly the temperature of the blood flow through a main blood vessel, such as the carotid artery. The method is applicable to veins as well.

Chato, J. C.↗

Further studies on the dimensionless parameters associated with the 'in vivo' transport of heat within biological tissue.

Dimensionless parameters appearing in the analysis of transport of heat within living biological tissues are presented and discussed. Dimensional analysis as well as some analytical solutions have been employed to obtain the physically and physiologically most significant dimensionless parameters associated with these types of problems. Some analytical solutions are presented for both steady state and transient cases to illustrate the significance of the derived parameters.-

Shitzer, A.↗

A linear combination of modified Bessel functions

A linear combination of modified Bessel functions is defined, discussed briefly, and tabulated. This combination was found to recur in the analysis of various heat transfer problems and in the analysis of the thermal behavior of living tissue when modeled by cylindrical shells.

Shitzer, A.↗

Steady-state temperature distribution in living tissue modeled as cylindrical shells.

Closed form, analytical solutions to the problem of steady-state heat transfer in living tissue modeled as cylindrical shells are presented and discussed. These solutions are particularly useful for the study of temperature distributions in the extremities. Metabolic heat generation, conduction, and heat transported by the blood perfusing the tissue are considered in the model. The results demonstrate the important role that the blood stream plays in the transfer of heat inside living tissue. Solutions are also presented for the limiting cases of diminishing blood flow that would occur during vasoconstriction or occlusion of blood by external means.

Shitzer, A.↗

Analytical solutions to the problem of transient heat transfer in living tissue.

An analytical model of transient heat transfer in living biological tissue is considered. The model includes storage, generation, conduction, and convective transport of heat in the tissue. Solutions for rectangular and cylindrical coordinates are presented and discussed. Transient times for reaching the ?locally fully developed' temperature profile were found to be of the order of 5 to 25 min. These transients are dominated by a geometrical parameters and, to a lesser extent, by a parameter representing the ratio of heat supplied by blood flow to heat conducted in the tissue.

Shitzer, A.↗

Steady state and transient temperature distributions in the human thigh covered with a cooling pad

An analytical and experimental study was done on the performance of cooling pads attached to a human thigh. Each cooling pad consisted of a long, water cooled tube formed into a serpentine shape with uniform spacing between the parallel sections. The analytical work developed a cylindrical model for the human thigh. The transient times predicted by this model ranged from 25 to 80 minutes, which is reasonably close to the experimental results. Calculated and measured steady state temperature profiles were in fair agreement. The transient times associated with a change from a high metabolic rate of 1800 Btu/hr (528 w) to a low level of 300 Btu/hr (88 w), were found to be about 120 minutes. A change from 300 Btu/hr (264 w) to 300 Btu/hr (88 w) resulted in 90 to 100 minute transients. However, the transient times for a change in metabolic rate in the opposite direction from 300 Btu/hr (88 w) to 1800 Btu/hr (528 w) were 40 to 60 minutes.

Leo, R. J.↗