An evaluation of the sandwich beam compression test method for composites
The sandwich beam in a four-point bending compressive test method for advanced composites is evaluated. Young's modulus and Poisson's ratio were obtained for graphite/polyimide beam specimens tested at 117 K, room temperature, and 589 K. Tensile elastic properties obtained from the specimens were assumed to be equal to the compressive elastic properties and were used in the analysis. Strain gages were used to record strain data. A three-dimensional finite-element model was used to examine the effects of the honeycomb core on measured composite mechanical properties. Results of the analysis led to the following conclusions: (1) a near uniaxial compressive stress state existed in the top cover and essentially all the compressive load was carried by the top cover; (2) laminate orientation, test temperature, and type of honeycomb core material were shown to affect the type of beam failure; and (3) the test method can be used to obtain compressive elastic constants over the temperature range 117 to 589 K.