Energy Information Systems: From the Basement to the Boardroom

A significant buildings energy reduction opportunity exists in the office sector, given that this market segment typically is an early adopter of new technology. There is a rising trend towards smart and connected offices through the internet of things (IoT) that provides new opportunities for operational efficiency and environmental sustainability practices. Leading commercial real estate companies have begun to shift from individual building automation systems (BAS) to partially integrated and automated systems such as energy information systems (EIS). In both the United States and India, organizations are seeking operational excellence, enhanced tenant relationships, and topline growth. Hence it is imperative to engage the executives with decision-making power, by tapping into their interest in sustainability, corporate social responsibility, and innovation. This expansion of interest can enable data-driven decisions, strong energy investments, and deeper energy benefits, and would drive innovation in this field. However, none of this would be possible without robust, consistent building energy information to provide visibility across all the levels of decision making, i.e. from the basement where the facilities staff take operational action to the boardroom where the executives make investment decisions. Price, security, and ease of use remain barriers to the adoption and pervasive use of promising EIS technologies in commercial office buildings. We believe that these barriers can be addressed through the development of ready, simplified, consistent, commercially available, low-cost EIS-in-a-box packages, that have a pre-defined set of hardware components and software features and functionality that are pertinent to a particular building sector. These simplified, sector-specific EIS packages can help to obviate the need for customization, and enhance ease of use, thereby enabling scale-up, in order to facilitate building energy savings. The EIS-in-a-box are adaptable in both U.S. and Indian office buildings, and potentially beyond these two countries.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

R&D and Implementation Outcomes from the U.S.-India Bilateral Center for Building Energy Research and Development Program

This paper explores the role of international partnerships to facilitate low-energy building design, construction, and operations. We present the strategic approach, joint research and development outcomes, and implementation activities of a unique U.S.-India program on buildings energy efficiency, the Center for Building Energy Research and Development. We discuss the collaboration successes in both countries despite their dissimilar building contexts, implementation challenges and opportunities. We highlight a range of R&D outcomes, such as novel tools and technologies developed and tested by the joint teams, with their technical energy savings potential, as well as results of capacity building and technology demonstrations. A deep-dive into key new scientific methods around building energy monitoring and benchmarking that could have a significant impact on high-performance of buildings in both countries is also provided. Finally, in addition to joint R&D successes, pathways to deployment, and lessons learned are discussed as key takeaways.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Packaged scalable energy information systems for hotels

Purpose: Building energy information systems (EIS) are performance monitoring software, data acquisition hardware and communication systems used to store, analyze and display building energy data. Some $60bn are spent annually on wasted energy in the US buildings, and actions taken based on EIS data can enable operational energy savings of approximately 10 per cent in the US commercial sector (approximately two quads of primary energy). However, EIS adoption is low because of various technical and market challenges. This paper aims to provide technical specifications for standardized EIS packages that can help overcome barriers and accelerate scale. Design/methodology/approach: Here, a five-step approach was followed: identifying business drivers as key determinants for hotel sector-specific packages; addressing heterogeneity to develop standardized, tiered packages; determining performance metrics for key stakeholders; recommending streamlined data architecture; and developing visualization enabling insights and actions. Findings: Technical specifications for two tiers (entry and advanced) of EIS packages for hotels have been developed. EIS vendor, integrator and client organization’s facilities and IT staff have been considered as key stakeholders. Findings from six field demonstrations show benefits of cost-effectiveness, through reduced transactional, first and operational costs, scalability, by accommodating heterogeneity across the building sub-sector, simplicity, by integrating meters, gateways and software in the package and actionability in organizations, across various decision-making levels. Originality/value: Building owners and operators can use these specifications to ease procurement and installation of EIS in their facilities. EIS software vendors can use them to develop new product offerings for underserved sectors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal characterization of full-scale PCM products and numerical simulations, including hysteresis, to evaluate energy impacts in an envelope application

This article presents combined measurements of fatty acid-based organic PCM products and numerical simulations to evaluate the energy benefits of adding a PCM layer to an exterior wall. The thermal storage characteristics of the PCM were measured using a heat flow meter apparatus (HFMA). The PCM characterization is based on a recent ASTM International standard test method, ASTM C1784. The PCM samples were subjected to step changes in temperature and allowed to stabilize at each temperature. By measuring the heat absorbed or released by the PCM, the temperature-dependent enthalpy functions for melting and freezing were determined.Here, the simulations were done using a previously-validated two-dimensional (2D) wall model containing a PCM layer and incorporating the HFMA-measured enthalpy functions. The wall model was modified to include the hysteresis phenomenon observed in PCMs, which is reflected in different melting and freezing temperatures of the PCM. Simulations were done with a single enthalpy curve based on the PCM melting tests, both melting and freezing enthalpy curves, and with different degrees of hysteresis between the melting and freezing curves. Significant differences were observed between the thermal performances of the modeled wall with the PCM layer under the different scenarios.

2D wall model with PCM↗

Calculating the Effect of External Shading on the Solar Heat Gain Coefficient of Windows

Current prescriptive building codes have limited ways to account for the effect of solar shading, such as overhangs and awnings, on window solar heat gains. We propose two new indicators, the adjusted Solar Heat Gain Coefficient (aSHGC) which accounts for external shading while calculating the SHGC of a window, and a weighted SHGC (SHGCw) which provides a seasonal SHGC weighted by solar intensity. We demonstrate a method to calculate these indices using existing tools combined with additional calculations. The method is demonstrated by calculating the effect of an awning on a clear double glazing in New Delhi.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Energy Benchmarking in India: an Action Plan for Advancing the State-of-the-Art

This document describes an action plan for advancing the state of the art of commercial building energy benchmarking in the Indian context. The document is primarily intended for two audiences: (a) Research and development (R&D) sponsors and researchers can use the action plan to frame, plan, prioritize and scope new energy benchmarking R&D in order to ensure that their research is market relevant; (b) Policy makers and program implementers engaged in the deployment of benchmarking and building efficiency rating programmes can use the action plan for policy formulation and enforcement .

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Guidelines for Datacenter Energy Information System

The purpose of this document is to provide structured guidance to data center owners, operators, and designers, to empower them with information on how to specify and procure data center energy information systems (EIS) for managing the energy utilization of their data centers. Data centers are typically energy-intensive facilities that can consume up to 100 times more energy per unit area than a standard office building (FEMP 2013). This guidance facilitates “data-driven decision making,” which will be enabled by following the approach outlined in the guide. This will bring speed, clarity, and objectivity to any energy or asset management decisions because of the ability to monitor and track an energy management project’s performance.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗