Search NASA⌕ Search

Engineering topics

Shumski, Alexander

Publications and source records attributed to Shumski, Alexander.

Multi-Parameter Optical Fiber for Distributed Sensing of Humidity, CH4, CO2, and Corrosion

This work describes the use of the optical fiber sensor (OFS) for successful monitoring of humidity, CH4, and CO2 based on the strain produced along the single-mode fiber (SMF) sensor. This is enabled by absorption of H2O/gases onto the commercially available polyacrylate coated jacketed portion of the fiber resulting in a change in strain. Under equilibrium, a differential microstrain was observed along the jacketed portion of the SMF with N2, CH4, and CO2 at different relative humidity (RH) conditions. The strain response of the SMF under various mixed gas composition and different RH conditions were also measured and made calibration curves accordingly. Linear regression and principal component analysis of the strain datasets provided deconvolution of the impact of strain from H2O, N2, CH4, and CO2. Additionally, modified OFS comprised of the Fe coated fiber section was employed to monitor corrosion based on the increase in backscattered intensity amplitude of the light being passed once corrosion of Fe occurs. Also, corrosion of Fe was studied under soil by installing the fiber in soil with protective measures which would prevent the sensor being mechanically disturbed or broken during installation. The corrosion rates were studied by monitoring the rate at which the intensity of backscattered light amplitude attains a steady state value when complete corrosion of Fe with a specific coating thickness occurs.

Mainali, Badri↗

Advanced Sensors for In-Situ Amine Degradation Monitoring in Post-Combustion Carbon Capture

In order to improve the long-term performance of post-combustion carbon capture technologies, improvements to the detection of solvent degradation or reduction in CO2 capture efficiency are necessary. A pair of sensors were deployed to the National Carbon Capture Center’s (NCCC) to monitor CO2 capture and solvent degradation. The CO2 sensors were located to measure before capture and after capture concentrations of CO2 to measure the capture efficiency of the solvent system. Amine degradation sensors were located at four locations along the main solvent lines corresponding to CO2 loading and temperature: hot rich, cold rich, hot lean, and cold lean. Experimental results from laboratory tests using the sensors are shown, along with prototype designs that were deployed to the field site.

Brister, Matthew↗

H2 Sensing with an Optical Fiber Sensor in the Subsurface H2 Storage Conditions

The concentration of hydrogen is subject to change due to biological reactions in the underground hydrogen storage reservoirs. Thus, monitoring hydrogen concentration in the subsurface gas deposits is vital to ensure the integrity and safety of the storage facilities. In this study, the optical fiber hydrogen sensor was developed and validated in relevant subsurface storage environments. Specifically, the sensor has demonstrated successful sensing performance at high temperatures (~80 °C) and high pressures (~1,000 psi) under very humid conditions (~100% RH). In addition, the sensor was exposed to real subsurface microbial samples to monitor microbially induced changes in hydrogen concentration. The sensor has shown stable H2 sensing responses in the replicated underground hydrogen storage conditions without deterioration or loss of H2 sensitivity. The biotic subsurface sample with hydrogen gas resulted in higher transmission intensity change than the abiotic sample due to the possible hydrogen consumption with microbes.

Kim, Daejin↗

SHASTA: Task 2.2: Sensor Development for Subsurface Hydrogen Storage Monitoring Technology Maturation and Commercialization Plan (TMCP)

In Task 2.2 under the SHASTA program, NETL is developing in-situ optical fiber sensors for real-time monitoring of hydrogen, methane, and chemical parameters such as pH at subsurface hydrogen storage conditions. This Technology Maturation and Commercialization Plan report will provide the summary of NETL sensor development and test results under the SHASTA program to meet the subsurface application requirements and proposed technology maturation and deployment plan, and commercialization potential.

08 HYDROGEN↗

Calcined Polyethyleneimine-Coated Optical Fibers for Distributed pH Monitoring at High Pressures and Temperatures

In the oil and gas, CO2 sequestration, H2 subsurface storage, and geothermal energy sectors, subsurface pH measurements are critical for monitoring the geochemical conditions and estimating potential corrosion rates of wellbore systems. Real-time pH measurements in these conditions are vital for detecting and predicting corrosion deterioration of wellbore components that may jeopardize the safety and continued operation of wellbore systems. Previous tests using metal oxide-based coatings (TiO2) provided strong responses at elevated temperatures and moderate pressure stability but provided poor differentiation between acidic and alkaline solutions. Building off the pH responsiveness of the TiO2 surface and known pH sensitivity of amine-based polymers, a coating based on the secondary amine polymer polyethyleneimine (PEI) was developed. As the polymer itself is highly water soluble and easily removed by aqueous solutions, the sensor coating was treated with a high temperature (500 °C) calcination procedure in air to convert it into a more stable oxidized coating capable of withstanding hot aqueous solutions without dissolving while retaining linear pH sensitivity from pH values between 2 and 11. The sensor performance was measured using optical transmission measurements in solutions of various pHs and using optical backscatter reflectometry for distributed pH sensing demonstration in wellbore-relevant pressures (up to 1,000 psi) and temperatures (80 °C).

Shumski, Alexander↗

Optical Fiber Sensors Capable of Monitoring Hydrogen in the Subsurface Hydrogen Storage Environment

Subsurface hydrogen storage is a cost-effective and environmentally friendly storage option in a large quantity. Hydrogen would be stored in subsurface storage reservoirs at high temperature/pressure under very humid condition. Monitoring hydrogen concentration in those harsh storage environments is crucial to ensure the integrity and safety of the hydrogen storage infrastructure. Thus, this project focuses on the development of optical fiber hydrogen sensors capable of monitoring hydrogen in the harsh environments that are representative of underground storage conditions. The optical fiber hydrogen sensor developed at NETL consists of a palladium-based sensing film with a filter layer which minimizes the environmental impacts on hydrogen sensing. The developed sensor has demonstrated significant improvement on hydrogen sensing at 80℃ under high humidity condition (99% RH) without the baseline drift. The hydrogen sensor also showed negligible cross-sensitivity to CO2 and CH4 which would be present as a cushion gas inside the underground hydrogen storage reservoir. Moreover, the sensor has demonstrated the stable monitoring of hydrogen concentration at high pressure (1000 psi) and 80 ℃ in the presence of biological samples. The optical fiber hydrogen sensor developed would enable reliable monitoring of hydrogen concentration in subsurface hydrogen storage facilities.

Kim, Daejin↗

Calcined Polyethyleneimine Coated Optical Fibers for Distributed pH Monitoring at High Pressures and Temperatures

In the oil and gas, CO2 sequestration, H2 subsurface storage, and geothermal energy sectors, subsurface pH measurements are critical for monitoring the geochemical conditions and estimating potential corrosion rates of wellbore systems. Real-time pH measurements in these conditions are vital for detecting and predicting corrosion deterioration of wellbore components that may jeopardize the safety and continued operation of wellbore systems. Building off of earlier TiO2 based pH sensors and the known pH sensitivity of amine-based polymers, a coating based on the secondary amine polymer polyethyleneimine (PEI) was developed. The sensor coating was treated with a high temperature (500 °C) calcination procedure in air to convert it into a more stable oxidized coating capable of withstanding hot aqueous solutions without dissolving while retaining linear pH sensitivity from pH values between 2 and 11. The sensor performance was measured using optical transmission measurements in solutions of various pHs and using optical backscatter reflectometry for distributed pH sensing demonstration in wellbore-relevant pressures (up to 1000 psi) and temperatures (80 °C). A calibration curve with strong differentiation between acidic and alkaline pH was developed for both transmission-based and distributed pH measurements, using fixed wavelength transmission and integrated linear amplitude of backscattered light for distributed measurements.

Shumski, Alexander↗

Multi-Parameter Optical Fiber Sensing of Humidity, CH4, CO2, and Corrosion

In this work, the previously demonstrated capability of the optical fiber sensor (OFS) for successful monitoring of humidity has been extended to monitor the humidity, CH4, and CO2 with different gas composition based on the strain produced along the single mode fiber (SMF) sensor. This is enabled by absorption of H2O/gases on to the commercially available polyacrylate coated jacketed portion of the fiber resulting a change in strain. Under equilibrium, a differential microstrain was observed along the jacketed portion of the SMF with N2, CH4, and CO2 at different humidity conditions, while the unjacketed portion of the fiber was used only for sensing pressure/temperature induced strain. In case of N2 at 800 psig pressure, the observed microstrain was approximately 80, 65, 50 and 35 µε at 100, 75.0, 46.8, and 23.4 RH% respectively. Comparatively, a microstrain of approximately 95 µε was observed with 100% RH CH4 which demonstrates that SMF produces a measurable CH4 response alongside water. Similarly, the observed microstrain with CO2 was approximately 105, 90, 85, 80, and 70 µε at 100, 75.0, 46.8, 23.4, and 0 RH% respectively. Linear regression and principal component analysis of these dataset provided deconvolution of the impact of strain from H2O, CH4, and CO2 enabling good cross sensitivity. Additionally, modified OFS comprising of Fe coated fiber section was employed to monitor corrosion, using Fe as corrosion proxy, under harsh corrosive environment.

Mainali, Badri↗

Multi-Parameter Optical Fiber Sensing of Humidity, CH4, CO2, and Corrosion

In this work, the previously demonstrated capability of the optical fiber sensor (OFS) for successful monitoring of humidity has been extended to monitor the humidity, CH4, and CO2 with different gas composition based on the strain produced along the single mode fiber (SMF) sensor. This is enabled by absorption of H2O/gases on to the commercially available polyacrylate coated jacketed portion of the fiber resulting a change in strain. Under equilibrium, a differential microstrain was observed along the jacketed portion of the SMF with N2, CH4, and CO2 at different humidity conditions, while the unjacketed portion of the fiber was used only for sensing pressure/temperature induced strain. In case of N2 at 800 psig pressure, the observed microstrain was ~80, ~65, ~50 and ~35 µε at 100, 75.0, 46.8, and 23.4 RH% respectively. Comparatively, a microstrain of ~95 µε was observed with 100% RH CH4 which demonstrates that SMF produces a measurable CH4 response alongside water. Similarly, the observed microstrain with CO2 was ~105, ~90, ~85, ~ 80, and ~70 µε at 100, 75.0, 46.8, 23.4, and 0 RH% respectively. Linear regression and principal component analysis of these dataset provided deconvolution of the impact of strain from H2O, CH4, and CO2 enabling good cross sensitivity. Additionally, modified OFS comprising of Fe coated fiber section was employed to monitor corrosion based on the increase in backscattered intensity amplitude of the light being passed once corrosion occurs.

Mainali, Badri↗