Search NASA⌕ Search

Engineering topics

Shwartz, Sharon

Publications and source records attributed to Shwartz, Sharon.

Second-order microscopic nonlinear susceptibility in a centrosymmetric material: application to imaging valence electron motion

We report measurements of phase-matched nonlinear x-ray and optical sum-frequency generation from single-crystal silicon using sub-resonant 0.95 eV laser pulses and 9.5 keV hard x-ray pulses from the LCLS free-electron laser. The sum-frequency signal appears as energy and momentum sidebands to the elastic Bragg peak. It is proportional to the magnitude squared of the relevant temporal and spatial Fourier components of the optically induced microscopic charges/currents. We measure the first- and second-order sideband to the 220 Bragg peak and find that the efficiency is maximized when the applied field is along the reciprocal lattice vector. For an optical intensity of $\sim10^{12} \text{W}/\text{cm}^2$, we measure peak efficiencies of $3\times 10^{-7}$ and $3\times 10^{-10}$ for the first and second-order sideband respectively (relative to the elastic Bragg peak). The first-order sideband is consistent with induced microscopic currents along the applied electric field (consistent with an isotropic response). The second-order sideband depends nontrivially on the optical field orientation and is consistent with an anisotropic response originating from induced charges along the bonds with C$_{3v}$ site symmetry. The results agree well with first-principles Bloch-Floquet calculations.

FOS: Physical sciences↗

Confirming X-ray Parametric Down Conversion by Time-Energy Correlation

We present measurements of X-ray Parametric Down Conversion at the Advanced Photon Source synchrotron facility. Using an incoming pump beam at 22 keV, we observe the simultaneous, elastic emission of down-converted photon pairs generated in a diamond crystal. The pairs are detected using high count rate silicon drift detectors with low noise. Production by down-conversion is confirmed by measuring time-energy correlations in the detector signal, where photon pairs within an energy window ranging from 10 to 12 keV are only observed at short time differences. By systematically varying the crystal misalignment and detector positions, we obtain results that are consistent with the constant total of the down-converted signal. Our maximum rate of observed pairs was 130 /hour, corresponding to a conversion efficiency for the down-conversion process of 5.3±0.5×10 -13 .

47 OTHER INSTRUMENTATION↗