Search NASA⌕ Search

Engineering topics

Siegfried, D. E.

Publications and source records attributed to Siegfried, D. E..

A phenomenological model for orificed hollow cathodes

A quartz hollow tube cathode was used to determine the operating conditions within a mercury orificed hollow cathode. Insert temperature profiles, cathode current distributions, plasma properties profile, and internal pressure-mass flow rate results are summarized and used in a phenomenological model which qualitatively describes electron emission and plasma production processes taking place within the cathode. By defining an idealized ion production region within which most of the plasma processes are concentrated, this model is expressed analytically as a simple set of equations which relate cathode dimensions and specifiable operating conditions, such as mass flow rate and discharge current, to such important parameters as emission surface temperature and internal plasma properties. Key aspects of the model are examined.

Siegfried, D. E.↗

A model for mercury orificed hollow cathodes - Theory and experiment

A phenomenological model is developed which provides a qualitative description of the basic physical processes taking place within a mercury orifice hollow cathode. This model can be used to predict, to first order, the important cathode operating parameters such as emission length and insert temperature. By assuming an idealized ion production region within which most of the plasma processes are concentrated, the model can be expressed analytically as a simple set of equations which relate cathode dimensions and specifiable operating conditions, such as mass flow rate and discharge current, to such important parameters as insert temperature and plasma properties. A comparison of theoretical and experimental results shows that, if the excited state energy flux is neglected, the model provides relatively accurate predictions of emission length, emission surface temperature, plasma density, and fraction of discharge current due to volume ionization

Siegfried, D. E.↗

A phenomenological model describing orificed, hollow cathode operation

A phenomenological model is presented which describes the emission processes occurring within the orificed, hollow cathode. The model defines a region of ion production inside the cathode and assumes that the cathode emission current can be accounted for by considering the ion and electron currents which cross the boundary of this region. Most of the current (approximately 72%) comes from electrons produced by field-enhanced, thermionic emission from a well-defined emission surface at the downstream end of the insert which circumscribes the ion product region. The electrons produced at the emission surface feed the ionization process in the region of ion production; the rest of the current (approximately 28%) is carried by the ions produced in the process. Moving at the Bohm velocity, these ions leave the production volume; they then complete the current path by being collected at various cathode potential surfaces, including the emission surface. The model establishes the ratio of ion to electron currents at the emission surface on the basis of the energy balance at that surface. Experimental results corroborating the principal assumptions of the model are presented and discussed.

Siegfried, D. E.↗

Studies on an experimental quartz tube hollow cathode

An experimental study is described in which a quartz tube, hollow cathode was operated in a test fixture allowing the simultaneous measurement of internal cathode pressure, insert temperature profiles, and the emission currents from various cathode components as a function of discharge current and propellant (mercury) mass flow rate for a number of different cathode orifice diameters. Results show that the insert temperature profile is essentially independent of orifice diameter but depends strongly on internal cathode pressure and emission current. The product of internal cathode pressure and insert diameter is shown to be important in determining the emission location and the minimum keeper voltage.

Siegfried, D. E.↗

An investigation of mercury hollow cathode phenomena

An experimental investigation is described in which measurements were made of plasma properties and other physical parameters upstream and downstream of the orifice plate of an operating mercury hollow cathode. These measurements included plasma property profiles, internal surface temperatures, internal pressure, and spectroscopic data of the external discharge. The results show the plume-to-spot mode transition to be characterized by significant changes in the plasma properties downstream of the cathode orifice, including the disappearance of an apparent electron free-fall region which is found to be present in the plume mode. The results also indicate the existence of a very dense plasma (10 to the 10th to 10 to the 14th electrons/cu cm) with steep electron density gradients in the region upstream of the orifice. The upstream data is found to correlate well with a modified form of the Saha equation. The related analysis indicates that the heavy particles approach thermal equilibrium with the electrons in the region of the orifice and that the ionization fraction in the orifice is very high - 80 to 100%.

Siegfried, D. E.↗