Search NASA⌕ Search

Engineering topics

Siegmund, O.

Publications and source records attributed to Siegmund, O..

Report of the ultraviolet and visible sensors panel

In order to meet the science objectives of the Astrotech 21 mission set the Ultraviolet (UV) and Visible Sensors Panel made a number of recommendations. In the UV wavelength range of 0.01 to 0.3 micro-m the focus is on the need for large format high quantum efficiency, radiation hard 'solar-blind' detectors. Options recommended for support include Si and non-Si charge coupled devices (CCDs) as well as photocathodes with improved microchannel plate readouts. For the 0.3 to 0.9 micro-m range, it was felt that Si CCDs offer the best option for high quantum efficiencies at these wavelengths. In the 0.9 to 2.5 micro-m the panel recommended support for the investigation of monolithic arrays. Finally, the panel noted that the implementation of very large arrays will require new data transmission, data recording, and data handling technologies.

Timothy, J. Gethyn↗

Delay line anodes for microchannel-plate spectrometers

A photon-counting readout system for microchannel-plate spectrometers is described that uses a delay line and timing circuit for the wavelength coordinate and a wedge-wedge charge division system for the orthogonal spatial coordinate. A novel zigzag layout allows these two anode patterns to coexist on a common planar substrate and share the charge from each photoevent, thereby simultaneously localizing the photon in each of its two dimensions. Unlike wedge-and-strip or resistive anode encoders, the delay line offers a spatial resolution that is relatively independent of the format length. Unlike discrete anode systems, the delay line readout system's complexity is also independent of the field of view size. These facts make the delay line readout system advantageous in large format detectors. A testbed detector having a delay line propagation speed of 2.2 mm/ns and a time resolution of 33 ps FWHM has been assembled. Ultraviolet testing shows a Gaussian event distribution having a 70-micron FWHM width; the readout system blur contribution is less than 50-micron FWHM.

Lampton, M.↗

High resolution large area modular array of reflectors /LAMAR/ Wolter type I X-ray telescope for Spacelab

The Spacelab Wolter type I X-ray telescope, which is intended for both astronomical observations and the functional verification of the future Large Area Modular Array of Reflectors (LAMAR) concept, comprises five mirrors and is designed to have a blur circle radius of 20 arcsec, with effective areas of (1) 400 sq cm at 0.25 keV, (2) 200 sq cm in the 0.5-2.0 keV range, and (3) 50 sq cm between 2 and 5 keV. A rotary interchange mechanism allows either of two imaging proportional counters to be placed at the telescope focus. The telescope's primary objective is the observational study of galactic and extragalactic X-ray sources, extending the work of the Einstein Observatory to fainter sources and higher energies. Secondarily, the costs and performance to be expected from the use of this telescope type in the LAMAR mission will be assessed.

Catura, R. C.↗