Search NASA⌕ Search

Engineering topics

Siegrist, Cathryn Michelle

Publications and source records attributed to Siegrist, Cathryn Michelle.

RingIR AG-4000 Testing

The AG-4000 detector can identify gas phase species using molecular fingerprinting and has potential application for SARS-CoV-2 detection in near real time. As part of the development process Sandia will utilize the biological aerosol test bed deployed at the Aerosol Complex to evaluate the penetration of MS2 bacteriophage aerosol through the Ring IR system. The objective of this project is to provide experimentally derived measurements of the RingIR AG-4000 penetration efficiency, including external exhaust filter for mitigation of exhaust aerosol and operation using MS2 bacteriophage as a biological surrogate to the SARS-CoV-2 virus.

60 APPLIED LIFE SCIENCES↗

Helpful Engineering's Universal Citizen Protection Device (UCPD)

The Universal Citizen Protection Device (UCPD) is a UV-based, filterless PPE concept developed by Helpful Engineering that aims to keep viral particles out of eyes, nose and mouth with a 99%+ reliability. The heart of the device is a concealed UV chamber that decontaminates all air going in and out of the PPE. The objective of this project was to provide measurements as evidence of proof of function of a representative prototype. Sandia utilized its aerosol characterization facility to measure the amount of virus that is inactivated by the device at representative flow rates and concentrations, using MS2 bacteriophage as the BSL-1 viral surrogate.

54 ENVIRONMENTAL SCIENCES↗