Search NASASearch

Engineering topics

Silver, Eric

Publications and source records attributed to Silver, Eric.

XIPE the X-Ray Imaging Polarimetry Explorer

X-ray polarimetry, sometimes alone, and sometimes coupled to spectral and temporal variability measurements and to imaging, allows a wealth of physical phenomena in astrophysics to be studied. X-ray polarimetry investigates the acceleration process, for example, including those typical of magnetic reconnection in solar flares, but also emission in the strong magnetic fields of neutron stars and white dwarfs. It detects scattering in asymmetric structures such as accretion disks and columns, and in the so-called molecular torus and ionization cones. In addition, it allows fundamental physics in regimes of gravity and of magnetic field intensity not accessible to experiments on the Earth to be probed. Finally, models that describe fundamental interactions (e.g. quantum gravity and the extension of the Standard Model) can be tested. We describe in this paper the X-ray Imaging Polarimetry Explorer (XIPE), proposed in June 2012 to the first ESA call for a small mission with a launch in 2017. The proposal was, unfortunately, not selected. To be compliant with this schedule, we designed the payload mostly with existing items. The XIPE proposal takes advantage of the completed phase A of POLARIX for an ASI small mission program that was cancelled, but is different in many aspects: the detectors, the presence of a solar flare polarimeter and photometer and the use of a light platform derived by a mass production for a cluster of satellites. XIPE is composed of two out of the three existing JET-X telescopes with two Gas Pixel Detectors (GPD) filled with a He-DME mixture at their focus. Two additional GPDs filled with a 3-bar Ar-DME mixture always face the Sun to detect polarization from solar flares. The Minimum Detectable Polarization of a 1 mCrab source reaches 14 in the 210 keV band in 105 s for pointed observations, and 0.6 for an X10 class solar flare in the 1535 keV energy band. The imaging capability is 24 arcsec Half Energy Width (HEW) in a Field of View of 14.7 arcmin 14.7 arcmin. The spectral resolution is 20 at 6 keV and the time resolution is 8 s. The imaging capabilities of the JET-X optics and of the GPD have been demonstrated by a recent calibration campaign at PANTER X-ray test facility of the Max-Planck-Institut fr extraterrestrische Physik (MPE, Germany). XIPE takes advantage of a low-earth equatorial orbit with Malindi as down-link station and of a Mission Operation Center (MOC) at INPE (Brazil). The data policy is organized with a Core Program that comprises three months of Science Verification Phase and 25 of net observing time in the following 2 years. A competitive Guest Observer program covers the remaining 75 of the net observing time.

Astronomy X-ray Polarimetry

Laboratory Astrophysics Using a Microcalorimeter and Bragg Crystal Spectrometer on an Electron Beam Ion Trap

We completed modifications to the new microcalorimeter system dedicated for use on the EBIT at NIST, which included: 1) a redesign of the x-ray calibration source from a direct electron impact source to one that irradiates the microcalorimeter with fluorescent x-rays. The resulting calibration lines are free of bremsstrahlung background; 2) the microcalorimeter electronic circuit was significantly improved to ensure long-term stability for lengthy experimental runs

Brinton, John

Constellation-X Microcalorimeter Development

Discussion topics: Review concept for NTD array construction. Tested revised fabrication tique: simpler construction; more rugged; and easier to control thermal properties. Development status. Related cryogenic infrastructure.

Kelly, Richard

Microcalorimeters with NTD and Expitaxial Germanium Thermistors for High Resolution X-Ray Spectroscopy

This is a progress report for the second year of a three year SR&T grant to continue the advancement of NTD-based microcalorimeters. We reported last year that we re-prioritized certain aspects of the statement of work and chose to emphasize issues of array development in the first year rather than wait until year two. Consequently, some of the projects scheduled for the first year were delayed to the second year and we report on those topics here. These include: a) Measurements that map out JFET , thermistor, l/f and feedback resistor noise; b) Investigations that evaluate the limits of the JFET preamplifier circuitry as it pertains to stability at the 2 eV level; The results of a) and b) have led to preliminary measurements that demonstrate 3.08 eV resolution at 6 keV. c) Calculations that can predict the current performance.

Silver, Eric

Laboratory Astrophysics using a Microcalorimeter and Bragg Crystal Spectrometer on an Electron Beam Ion Trap

During the past year we have been preparing our new microcalorimeter system for permanent delivery to the NIST EBIT. Unfortunately, there have been delays due to technical difficulties in the fabrication of the two-stage adiabatic demagnetization refrigerator and in the life expectancy of the thin windows used for internal thermal baffling of the infrared radiation. These problems have been solved and we are completing tests of the entire system and it will be set up at NIST during the first week of May. Several photos of the new system are shown in Figures 1A and 1B. This microcalorimeter spectrometer only requires helium refills every three days (as opposed to every 24 hours) and it will hold a temperature! of 65 mK for up to 48 hours (as opposed to 8 hours). Consequently, the efficiency of data acquisition will improve dramatically. In parallel we have published a paper that reviews our previous work (Takacs et al. 2003), especially on Fe XVII, in the context of recent measurements by other groups. This paper is included. We highlight a recent measurement of a broad band spectrum of Fe in Figure 2 that simultaneously includes L and K radiation. It is compared with the simulated spectrum of the Perseus Cluster that one could expect to obtain with a microcalorimeter in the focus of a grazing incidence telescope such as the one being designed for Constellation X. Both the charge state distributions and the relative intensity ratios of the emission lines within the particular charge state are very similar in the two spectra. This further demonstrates the importance and relevance of the laboratory measurements in predicting the components of cosmic spectra.

Brinton, John C.

Laboratory Astrophysics using a Microcalorimeter and Bragg Crystal Spectrometer on an Electron Beam Ion Trap

When we last reported, our new microcalorimeter system was being prepared for delivery and permanent installation at the NIST EBIT. This occurred in June 2003 and check-out with the internal calibration source and EBIT plasma x-rays took place over the next several months during which time we modified several component parts to improve the performance. These changes included: 1) A redesign of the x-ray calibration source from a direct electron impact source to one that irradiates the microcalorimeter with fluorescent x-rays. The resulting calibration lines are free of bremsstrahlung background; 2) The microcalorimeter electronic circuit has been significantly improved to ensure long-term stability for the lengthy upcoming runs of the EBIT. Both the preamplifier feedback resistors were changed and the first stage of the preamplifier redesigned. Several photos of the new system are shown in slides 3 and 4. This microcalorimeter spectrometer only requires helium refills every three days (as opposed to every 24 hours in our earlier system) and it will hold a temperature of 65 mK for up to 48 hours (as opposed to 8 hours). Consequently, the efficiency of data acquisition will improve dramatically. The first x-ray spectra of the new calibration source made with the 4-element detector array is shown. An example of the temperature control capabilities of the ADR for a 23 hour interval is shown. The horizontal line shows the temperature stability (about +/- 3 micro kelvin). There are a few short-lived heating excursions caused by technical staff working on the EBIT machine simultaneously. During actual experimental runs these are absent. This temporal profile was interrupted to test additional components of the system; otherwise, the temperature controlling would have continued for another 24 hours.

Silver, Eric

A Focal Plane Stellar X-Ray Polarimeter for SXG

This report covers progress on a grant for the Stellar X-Ray Polarimeter (SXRP). SXRP is the only X-ray polarimeter designed to view astrophysical sources that is currently scheduled to be flown. The SXRP is one of eight astronomical X-ray instruments that intended to be flown at the focal plane of the two SODART large-area metal-foil grazing-incidence X-ray telescopes on the Russian Spectrum-Roentgen-Gamma (SRG) mission.

Christensen, Larry

Design and Development of Thin Plastic Foil, Conical Approximation, High Through-out X-Ray Telescope: Light Weight, Thin Plastic Foil, X-Ray Telescopes

We present results from a program to develop an X-ray telescope made from thin plastic shells. Our initial results have been obtained from multi-shell cylindrical lenses that are used in a point-to-point configuration to image the small focal spot of a an X-ray tube on a microchannel plate detector. We describe the steps that led up to the present design and present data from the tests that have been used to identify the properties of the plastic material that make it a suitable X-ray reflector. We discuss two applications of our technology to X-ray missions that are designed to address some of the scientific priorities set forth in NASA's long term plans for high energy astrophysics. One mission will observe in the 1 - 10 keV band, the other will extend up to ca. 100 keV.

Schnopper, Herbert W.

NTD-GE Based Microcalorimeter Performance

Our group has been developing x-ray microcalorimeters consisting of neutron transmutation doped (NTD) germanium thermistors attached to superconducting tin absorbers. We discuss the performance of single pixel x-ray detectors, and describe an array technology. In this paper we describe the read-out circuit that allows us to measure fast signals in our detectors as this will be important in understanding the primary cause of resolution broadening. We describe briefly a multiplexing scheme that allows a number of different calorimeters to be read out using a single JFET. We list the possible causes of broadening and give a description of the experiment which best demonstrates the cause of the primary broadening source. We mention our strategy for finding a suitable solution to this problem and describe briefly a technology for building arrays of these calorimeters.

Bandler, Simon

A new thermal sensor for X-ray microcalorimetry

A concept for a detector is introduced which exploits the significant temperature dependence of the dielectric constant in ferroelectric materials. The concept permits the use of a microcalorimeter without the resistive sensors which are associated with heat dissipation and increased Johnson noise in the electronic conversion circuit. General calorimeter features are listed, and the concepts related to dielectric calorimeters are discussed in terms of operational and detection advantages. The use of the device is delineated both theoretically and experimentally with the results of an operational dielectric material. The mixed-crystal quantum ferroelectric is employed and detects 6 MeV alpha particles while operating at 1.2 K in the first detection conducted. The temperature dependence of the dielectric constant in the materials allows for the elimination of resistive sensors in microcalorimeters, thereby improving the ultimate sensitivity of the instrument.

Silver, Eric