Search NASA⌕ Search

Engineering topics

Silvers, Kurt L.

Publications and source records attributed to Silvers, Kurt L..

Radiation monitoring devices and associated methods

Radiation monitoring devices and associated methods are described. According to one aspect, a radiation monitoring device includes a housing configured to pass radiation emitted from a radiological source located in proximity to the radiation monitoring device, a radiation detector configured to receive the radiation emitted from the radiological source and to generate information regarding the radiation, and communications circuitry configured to communicate the information regarding the radiation in a plurality of communications at a plurality of different moments in time externally of the radiation monitoring device.

Burghard, Brion J.↗

Abatement Case Study

Radioxenon emissions from industrial sources such as fission based medical isotope production (MIP) facilities and nuclear reactors are generally known to be well below levels of public health and safety concern. However, the global background of radioxenon produced by MIP interferes with nuclear explosion monitoring by the International Monitoring System (IMS) developed for the Comprehensive Nuclear-Test-Ban Treaty (CTBT) (CTBTO, 2024). It was calculated that xenon emissions levels of 5×10 9 Bq/day 133 Xe were low enough to have minimal impact on International Monitoring System (IMS) stations (Bowyer et al, 2013). There are several technologies currently used to abate radioactive xenon emissions to meet regulatory release levels, and some alternative methods have been investigated to reduce xenon release levels well below required regulatory levels (Doll et al, 2014, Gueibe, et al, 2014). While MIP producers are sympathetic to the issue of radioxenon interference with IMS monitoring, the cost to implement and maintain additional abatement systems has resulted in limited implementation. Therefore, more cost-effective options for xenon abatement are needed to help reduce the impact of these emissions on nuclear explosion monitoring.

07 ISOTOPE AND RADIATION SOURCES↗

Impact of Radiolysis on Iodine Speciation in a Variety of Matrices

This report details the work conducted in fiscal year 2023 with the aim of providing a better understanding of the speciation of iodine in support of domestic 99 Mo production Shine who uses a sulfate matrix in their process. Laboratory experiments to study the behavior of iodine speciation were conducted using spectroscopic methods including UV-vis and Raman as well as electrochemical studies. Radiolysis occurring in solution presents a unique challenge that is largely unaddressed with thermodynamic modeling, therefore a kinetic model was developed to address these issues. The focus of the studies conducted this year used surrogate radiolytic conditions induced by hydrogen peroxide for comparison to radiolytic conditions from direct gamma irradiation and neat acid solutions. For each case a model incorporating the kinetics was used to predict iodine speciation in the defined conditions where the output was directly compared to the experimental conditions. Further modeling was conducted incorporating the process conditions that are specific to Shine with incorporation of radiolysis and gas sparging.

07 ISOTOPE AND RADIATION SOURCES↗

Control of iodine and tellurium for use in domestic molybdenum-99 production efforts

Three initial proof-of-concept experiments were performed to test the removal of I and Te from solutions containing Mo for potential abatement during chemical processing to purify 99 Mo. All three proof-of-concept experiments produced results indicating that further optimization could provide methods for I and/or Te abatement from multiple matrices. Decamp and Happel (2013) describe the use of CL resin from Eichrom Technologies loaded with Ag + combined with Amberlite XAD-4 in the chromatographic separation of irradiated fission products in 1 M HNO 3 to separate iodine species where iodide and iodate react with Ag + and I2 adheres to the Amberlite resin. The method worked well under processing conditions in a medical isotope facility although many separation methods use higher concentrations of HNO 3 which could adversely impact the Ag + loading. The experiment performed here used a roughly 2 mL column of CL resin loaded with Ag + and Amberlite XAD-4 to separate µg quantities of I, Te, and Mo in 3 M HNO 3 .

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Serial Moire scanning phase contrast x-ray imaging

Method include emitting x-rays from an x-ray source, directing a first portion of the x-rays through an object grating situated adjacent to an object while the object is scanned relative to the object grating along a scan direction, directing a second portion of the x-rays through the object and subsequently through a detector grating without transmitting through the object grating, wherein the object grating and detector grating are adjacently arranged in a field of view of the x-rays sequentially with respect to each other in the scan direction, and receiving the first portion transmitted through the object and object grating with a first portion of a detector and receiving the second portion transmitted through the object and the detector grating with a second portion of the detector adjacent to the first portion of the detector. Systems are also disclosed, along with related techniques for beam hardening correction.

Miller, Erin A.↗

High Throughput Argon-37 Field System

We report Pacific Northwest National Laboratory (PNNL) has developed a unique fieldable 37 Ar measurement system designed to measure 37 Ar activity concentrations from soil gas samples to detect above ground and underground nuclear explosions. The Argon-37 Field System is modular in design to accommodate both chemical processing and nuclear detection. The system can be packed into shipping crates and shipped to a location near where the sampling is taking place. The system can process six 2-m 3 whole-air samples in 24 hours and can measure the 37 Ar activity in each of the samples using six proportional counters. The proportional counters, designed and built at PNNL, are surrounded with both active and passive shielding to reduce background and can achieve a minimum detection concentration of 10 mBq/m 3 of 37 Ar in whole-air equivalent. The Argon-37 Field System has undergone extensive testing against rigorous requirements to assure the system meets the needs of the noble gas nuclear explosion monitoring community.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Experimental Analysis of a Piezoelectric Energy Harvesting System for Harmonic, Random, and Sine on Random Vibration

Formal journal article Experimental analysis of a piezoelectric energy harvesting system for harmonic, random, and sine on random vibration Abstract: Harvesting power with a piezoelectric vibration powered generator using a full-wave rectifier conditioning circuit is experimentally compared for varying sinusoidal, random and sine on random (SOR) input vibration scenarios. Additionally, the implications of source vibration characteristics on harvester design are discussed. Studies in vibration harvesting have yielded numerous alternatives for harvesting electrical energy from vibrations but piezoceramics arose as the most compact, energy dense means of energy transduction. The rise in popularity of harvesting energy from ambient vibrations has made piezoelectric generators commercially available. Much of the available literature focuses on maximizing harvested power through nonlinear processing circuits that require accurate knowledge of generator internal mechanical and electrical characteristics and idealization of the input vibration source, which cannot be assumed in general application. In this manuscript, variations in source vibration and load resistance are explored for a commercially available piezoelectric generator. We characterize the source vibration by its acceleration response for repeatability and transcription to general application. The results agree with numerical and theoretical predictions for in previous literature that load optimal resistance varies with transducer natural frequency and source type, and the findings demonstrate that significant gains are seen with lower tuned transducer natural frequencies for similar source amplitudes. Going beyond idealized steady state sinusoidal and simplified random vibration input, SOR testing allows for more accurate representation of real world ambient vibration. It is shown that characteristic interactions from more complex vibrational sources significantly alter power generation and power processing requirements by increasing harvested power, shifting optimal conditioning impedance, inducing significant voltage supply fluctuations and ultimately rendering idealized sinusoidal and random analyses insufficient.

alternative power↗

Missile Captive Carry Monitoring and Helicopter Identification Using a Capacitive Microelectromechanical Systems Accelerometer

Military missiles are exposed to many sources of mechanical vibration that can affect system reliability, safety, and mission effectiveness. The U. S. Army Aviation and Missile Research Development and Engineering Center (AMRDEC) has been developing missile health monitoring systems to assess and improve reliability, reduce life cycle costs, and increase system readiness. One of the most significant exposures to vibration occurs when the missile is being carried by a helicopter or other aviation platform, which is a condition known as captive carry. Recording the duration of captive carry exposure during the missile’s service life can enable the implementation of predictive maintenance and resource management programs. Since the vibration imparted by each class of helicopter varies in frequency and amplitude, tracking the vibration exposure from each helicopter separately can help quantify the severity and harmonic content of the exposure. Under the direction of AMRDEC staff, engineers at the Pacific Northwest National Laboratory have developed a Captive Carry Health Monitor (CCHM) for the Hellfire II missile. The CCHM is an embedded usage monitoring device installed on the outer skin of the Hellfire II missile to record the cumulative hours the host missile has been in captive carry mode. To classify the vibration by class of helicopter, the CCHM analyzes the amplitude and frequency content of the vibration with the Goertzel algorithm to detect the presence of distinctive rotor harmonics. Cumulative usage data are accessible in theater from an external display; monthly usage histograms are accessible through an internal download connector. This paper provides an overview of the CCHM electrical and package design, describes field testing and data analysis techniques used to monitor captive carry identify and the class of helicopter, and discusses the potential application of missile health and usage data for real-time reliability analysis and fleet management.

Goertzel, HUMS↗