Search NASA⌕ Search

Engineering topics

Simner, Steven

Publications and source records attributed to Simner, Steven.

Evaluating the Chemical Resistance of Salt-stone Disposal Unit (SDU) Concrete and Polymeric Coatings - 18494

Salt-stone Disposal Units (SDUs) are multi-million liter concrete structures that are used at the Savannah River Site (SRS) for the permanent disposal of low-activity salt solution incorporated in a cementitious grout matrix, termed salt-stone. The major chemical constituents of the salt solution include sodium, aluminum, nitrate, nitrite, hydroxide, carbonate, and sulfate. The potential exists for the SDU interior to be chronically exposed to these corrosive constituents resulting in deleterious reactions and physical damage. Sulfate attack is an example of such an interaction whereby aqueous sulfates may penetrate the concrete, and react with hydration products in the cured concrete to form expansive phases that can cause excessive strains and cracking. Recently constructed SDUs have utilized sulfate-resistant Type V cement and polymeric coatings to minimize the potential impacts of SDU concrete exposure to the highly caustic (pH > 13) salt solution. Not only must the concrete and coatings exhibit high resistance to the caustic salt solution but they are also subjected to above ambient temperatures due to the exothermic nature of the grout hydration reaction. As such, both the SDU concrete and the coatings need to be tested with respect to stability in the aforementioned chemical and thermal environments. Two primary investigations were considered in this work. The first was to evaluate the resistance of two previously used epoxy coatings (Hempel Versiline TL-45 S Novolac and EC-66 elastomeric epoxies) to chemical attack from a simulated salt solution. In addition, a third coating was included in the study, a poly-urea coating (Sherwin Williams Envirolastic AR425) that may be considered as an alternative to the epoxy coatings on future SDUs. Each coating was applied to concrete cylinders (actual SDU 6 test cores) and subsequently exposed to salt-stone, or full and half strength caustic salt solution; 50% dilution was considered since salt-stone processing involves addition of flush water to the SDUs, which is expected to dilute any residual salt solution or bleed water in the SDU. Exposure testing was conducted at 68 deg. C for 1,000 hours followed by ambient exposure to provide a full exposure time of approximately 90 days. It is important to note that evaluation criteria for the coated materials were only visual in nature. Other than coating discoloration, which was limited to the surfaces, no other visual indications of reactivity between the three coatings and any of the exposure mediums were observed. Cross-sectioned samples indicated no through-thickness coating penetration or reaction, and showed no signs of delamination. The second investigation was also performed to determine if SDU concrete without a polymeric barrier would resist ingress and reaction with salt solution at the elevated temperature. Again, only slight discoloration of the concrete surfaces was observed after the 90-day exposure test irrespective of the salt solution concentration. A requirement of structural concrete in the SDUs is that it possesses a minimum compressive strength of 42 MPa (6,000 psi). The average compressive strength of samples exposed to the full-strength salt solution was recorded at 68 MPa compared to 66 MPa for the unexposed samples thus indicating that the exposure conditions considered in this study were not detrimental to the concrete strength. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dynamic Leaching Method for Intact Salt-stone Samples - 18495

At the Savannah River Site (SRS) low activity salt solution is stabilized via encapsulation within a grout termed salt-stone. Salt-stone is emplaced into large (multi-million liter) concrete storage containers referred to as Salt-stone Disposal Units (SDUs). Technetium-99 (Tc-99) and iodine-129 (I-129) are long-lived radionuclides contained in the low activity salt waste and subsequently incorporated into the grout waste form: both radionuclides are contributors to the potential long-term radiation exposure of the public and environment surrounding the SDUs. With respect to Tc-99, in the reducing, high pH environment within the grout, Tc-99 is expected to be relatively immobile since it exists in a reduced Tc(IV) oxidation state in the form of sparingly soluble hydrated oxides (TcO{sub 2}.xH{sub 2}O) or sulfides (TcS{sub x}). However, in the presence of O{sub 2} (associated with the future infiltration of air or oxygenated ground waters into the salt-stone monolith) it is possible for redox-sensitive Tc(IV) to transition into highly soluble (and mobile) Tc(VII) species, such as pertechnetate (TcO{sub 4}{sup -}), which are more readily transported to the surrounding environment. In contrast, I-129 is highly soluble and its leaching behavior is not anticipated to be significantly impacted by potential changes in redox environment or pH within salt-stone. Traditional approaches to quantifying the leaching behavior of Tc-99 and I-29 from cementitious matrices have involved partitioning experiments using size-reduced (crushed/ground) samples, and determination of the radionuclide fraction immobilized by the cementitious solids. Such experiments create artificially high solid-liquid contact areas that likely result in higher Tc-99 and I-129 leachate concentrations than would be expected for intact, monolithic samples. In the current study a new technique, termed the Dynamic Leaching Method (DLM), is being used to initially investigate the Tc-99 leaching behavior from monolithic salt-stone samples; the system will be used at a later date to evaluate the leaching characteristics of I-129. The data derived using this technique is intended to inform the SRS Salt-stone Disposal Facility (SDF) Performance Assessment (PA) which models the long-term transport of radionuclides from the SDUs to the environment. The DLM utilizes a flexible-wall permeameter to achieve saturated leaching under an elevated hydraulic gradient to simulate and accelerate the future transport of groundwater through salt-stone. Leachates are regularly analyzed with respect to radionuclide concentrations, key constituent concentrations (e.g., Al, Ca, Mg, Na, Si, CO{sub 3}{sup 2-}, NO{sub 2}{sup -}, NO{sub 3}{sup -}, SO{sub 4}{sup 2-}), pH, and reduction potential (E{sub h}) in order to develop an understanding of how chemical changes associated with the pore solution influence grout weathering and radionuclide leaching behavior. This paper provides a brief update with respect to data derived from preliminary Tc-99 leaching evaluations as the DLM was being developed, but the paper is predominantly focused on new sample data in which the DLM technique, pre- and post-DLM salt-stone sample characterization, and leachate analysis protocols have been optimized. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation and Interpretation of Properties for Saltstone Cores Extracted from an SDU - 17344

Extraction and subsequent analysis of emplaced saltstone samples from a Savannah River Site (SRS) Saltstone Disposal Unit (SDU) were performed in order to realize the following key objectives: (1) to support the use of historical and future laboratory-derived sample data to predict the behavior of field-emplaced samples, and (2) to substantiate the saltstone properties currently assumed in Saltstone Disposal Facility (SDF) transport modeling, i.e., Performance Assessment (PA) and Special Analyses (SA) models. Multiple cores were extracted via a wet core drilling process in April-May 2015 approximately 20 months after the saltstone of interest was processed in the Saltstone Production Facility (SPF) and subsequently emplaced in SDU Cell 2A (SDU2A). The retrieved samples were stored in an inert N{sub 2} environment prior to, and during, the property testing that took place between October 2015 and March 2016. Sample analyses comprised evaluation of physical properties (density, porosity, and moisture content), saturated hydraulic conductivity (K{sub sat}), and determination of distribution coefficients and solubilities for key radionuclides. In general the SDU2A samples indicated comparative properties to laboratory-prepared samples and additionally verified many of the inputs currently assumed in the SDF PA. The principal exception was related to the leaching characteristics of I-129, which demonstrated a lower than anticipated affinity for retention within the saltstone matrix. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Contaminant Leaching From Intact Saltstone Monoliths - 17517

At the Department of Energy's (DOE's) Savannah River Site (SRS) chemically reducing materials, such as blast furnace slag (BFS), are added to grout formulations mixed with low-level radioactive salt solution in order to enhance the attenuation of redox sensitive contaminants (e.g., technetium-99 (Tc-99)). The resulting cementitious material, known as saltstone, is deposited in a series of concrete vaults for permanent disposal at the Saltstone Disposal Facility (SDF). Under oxidizing conditions, Tc persists as an anion in the +7 oxidation state, i.e., pertechnetate (TcO{sub 4}{sup -}), with very limited retention generally associated with amphoteric soil oxides. However, Tc(VII) is subject to chemical reduction to the +4 oxidation state, which is less soluble and mobile in the environment. Thus, chemically reducing grouts provide both a physical (i.e., low saturated hydraulic conductivities (K{sub sat}) that limit H{sub 2}O turnover and O{sub 2} exposure) and chemical barrier (i.e., residual reductive capacity) to contaminant release. However, many of the previous experiments evaluating the ability of saltstone to chemically reduce and immobilize Tc have been conducted using ground saltstone materials as sorbents, a practice that is likely to reduce the moisture level in the material, enhance exposure to O{sub 2} and alter sorbent properties in an unpredictable manner. Therefore, the objective of the current study was to evaluate contaminant leaching from intact monoliths that better represent the initial physical and chemical state of saltstone within the SDF disposal units. For the current study, saltstone simulants were produced utilizing SRR prescribed formulations: initial batches were spiked with rhenium (Re) to serve as nonradioactive analog for Tc-99, and subsequent batches were spiked with Tc-99 for comparison. The relative concentrations of I, Re and Tc-99 in the salt-waste simulants were consistent with the average concentrations of I-129 and Tc-99 in the low-level feed waste. In addition, SRR retrieved intact monoliths from Saltstone Disposal Unit (SDU) Cell 2A in 2015 for testing. Contaminant mass transfer rates for Tc-99 and other contaminants from spiked saltstone simulants and actual SDF saltstone samples were assessed using EPA Method 1315, Mass Transfer Rates of Constituents in Monolithic or Compacted Granular Materials Using a Semi-Dynamic Tank Leaching Procedure. This method was recently adopted for evaluating contaminant leaching from intact monolithic materials. Given the importance of redox speciation in controlling the mobility of Tc-99, the EPA mass transfer tests for the spiked simulants were initially conducted using leachates in equilibrium with three different test atmospheres: (1) oxic, (2) anoxic, and (3) anoxic reducing. Nitrate (NO{sub 3}{sup -}) leaching was evaluated as a poorly retained waste constituent. The leaching behavior of cesium-137 (Cs-137), representing about 98% of the initial radioactivity of the saltstone, was also evaluated for the SDU-extracted samples. Results from Method 1315 were also compared to a novel Dynamic Leaching Method (DLM) in which a flexible-wall permeameter was used to achieve saturated leaching under an elevated hydraulic gradient in an effort to evaluate the persistence of reductive capacity and subsequent changes in contaminant partitioning within intact saltstone monoliths. The composition of the chemical leachates from both tests was thoroughly analyzed in an effort to identify potential solid phases controlling contaminant partitioning through geochemical modeling. For the EPA 1315 tests using spiked simulants, Re leaching rates (and other poorly sorbing contaminants like NO{sub 3}{sup -} and iodine), as indicated by high effective diffusivities (D{sub e}) and low leachability indices (i.e. LI = - log[D{sub e}]), were much higher than Tc-99, which was attributed to poor initial reduction and/or rapid oxidation of Re, indicating that Re is a poor chemical analog for evaluating Tc partitioning under reducing conditions. Technetium-99 leaching rates for the spiked saltstone samples also appeared to be sensitive to the estimated reduction capacity of the dry feed materials used in making grout, a characteristic that can vary between different BFS sources. Technetium-99 leaching rates for the intact saltstone samples in the EPA 1315 test were quite similar, with less variability between the three test samples. This may be indicative of the longer curing time before the SDF samples were tested (∼3 years). Somewhat surprisingly, the leaching rates for Cs-137 from the SDF samples were generally lower than the poorly sorbing contaminants, NO{sub 3}{sup -} and iodine. For the DLM tests, Re leaching from spiked saltstone was much higher than observed for Tc-99, with rates similar to that of non-reactive grout constituents, consistent with EPA 1315 leaching rates. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Selection and Validation of Alternate Slag Sources for Saltstone Production - 16145

To stabilize low activity salt solution produced at the Savannah River Site (SRS) the salt waste is mixed with a combination of fly ash (FA), ground granulated blast furnace slag (GGBFS), and ordinary Portland cement (OPC) to form a grout termed saltstone. Upon curing, the low activity waste is encapsulated within the hardened cementitious matrix. While the sources of the dry feed components have remained unchanged for several years, SRS was recently notified that its domestic source of GGBFS would no longer be available due to the shutdown of the steel making plant that produced the ferrous slag as a by-product. This shut-down follows a trend in the reduction of domestic ferrous slag sources. Alternate GGBFS vendors were sought and a program developed to validate the alternate sources for use in saltstone. GGBFS is primarily utilized in the construction industry as a replacement for OPC and the requirements of a GGBFS source, based on an American Society for Testing and Materials (ASTM) standard, are predominantly limited to demonstrating that the GGBFS replacement will provide equivalent strength in comparison to the baseline OPC-based concrete. This affords the construction industry significant flexibility with respect to the GGBFS source that can be used. In contrast, GGBFS has a role of significantly more importance when utilized in saltstone. In particular, the reducing blast furnace environment under which GGBFS is produced yields reducing species, such as sulfide (S{sup 2-}) and ferrous iron (Fe{sup 2+}), which are believed to facilitate the long-term immobilization of redox sensitive contaminants (e.g. technetium-99 ({sup 99}Tc)). In addition, a change in GGBFS source has the potential to impact the rheological properties and the reactive heat generation of the grout, which may adversely affect the ability to pump the grout to a Saltstone Disposal Unit (SDU) and the temperatures attained within an SDU, respectively. As such, alternate GGBFS sources for the processing of saltstone require significantly more scrutiny than is prescribed by the ASTM standard. Four alternate GGBFS sources were evaluated. All four sources met the ASTM requirements, only one source was considered viable for use in saltstone based on preliminary evaluation. The other three sources will require a more intensive assessment to determine their potential applicability. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Update on SRNL Support of Saltstone Sampling and Analysis - 16325

At the Savannah River Site, low-level waste is immobilized in cementitious waste form known as saltstone. The saltstone Performance Assessment models the performance of the waste form and other aspects of the Saltstone Disposal Facility over ten thousand years after closure to determine the transport history of radionuclides and other hazardous constituents in low-level waste. As part of an ongoing Performance Assessment Maintenance Plan, Savannah River Remediation with Savannah River National Laboratory, has designed a sampling and analyses plan to correlate the properties of field-emplaced samples and samples processed and cured in the laboratory. As part of the plan, SRR has retrieved field-emplaced samples from SDU 2A. Prior to analyzing the field emplaced samples, SRNL is developing the strategy, protocols and equipment necessary to retrieve, store in an inert environment, and analyze the three sample sets of interest outlined in the analysis plan. To date, the simulant saltstone samples have been analyzed for hydraulic conductivity, porosity, density, and other properties. This paper will give an update to the current protocols and equipment being utilized at Savannah River National Laboratory for storing and analyzing the field-emplaced and simulant samples, results from the simulant saltstone analyses, as well as analysis plans for the samples retrieved from the Saltstone Processing Facility and the field-emplaced samples. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simulating field conditions for the curing of salt-stone - 15501

salt-stone is a cementitious, low-level waste (LLW) material processed and stored at the Savannah River Site (SRS). It consists of fly ash (FA), blast furnace slag (BFS), and Portland cement that are blended with LLW salt solution. The dry feed materials and the salt solution are mixed at the salt-stone Production Facility (SPF), and the fresh grout subsequently pumped into a salt-stone Disposal Unit (SDU) in the salt-stone Disposal Facility (SDF) where it cures to form a rigid, cementitious monolith. In order to demonstrate the long-term performance of salt-stone, non-radioactive simulant samples are processed and cured in a laboratory environment and subsequently tested with respect to key performance properties. Of particular relevance to assessing the long-term stabilization and immobilization of radionuclides in salt-stone is the permeability, or saturated hydraulic conductivity, which determines the rate of infiltration for oxygen-bearing ground waters that can affect redox sensitive contaminants, such as {sup 99}Tc. Environmental conditions in the SDU, in particular temperature and humidity, are believed to affect the cured properties of salt-stone. With respect to humidity it has been determined that the average vapor space humidity in an SDU is at least 95%, and in addition the assumption can be made that underlying grout is subjected to a moisture-saturated environment by the grout poured over it. With respect to temperature, the SDUs contain thermo-well arrays that provide detailed vertical, and to a lesser degree radial, temperature profiles. Temperature data from the SDUs have subsequently been utilized to better simulate curing temperatures for simulant salt-stone in the laboratory. However, no two thermal profiles are the same, varying with respect to the following parameters: initial temperature, rate of temperature increase, maximum temperature attained, time at maximum temperature, and cooling rate. These temperature variables are dependent on the depth of grout (due to insulating effects of underlying and overlying grout), frequency of grout addition to the SDU (with more frequent additions causing grout temperatures to rise due to the exothermic hydration reactions), and, to a lesser degree, the ambient temperature of the external environment. Due to the variability in each thermal profile recorded in an SDU, the question arises as to which profile (or profiles) should be used in the simulated laboratory environment to best mimic the curing of field emplaced salt-stone, such that there is confidence that the properties measured for laboratory-prepared samples are representative of the grout in the SDU. Since the current SDU design contains sixty-six thermo-wells it is obviously not practical to process simulant samples according to each profile. Rather the aim would be to choose a reduced number of profiles that adequately encompass the range of recorded profiles, or to choose a single profile that is considered most conservative with respect to the resulting properties of interest. This is typically thought to be the profile exhibiting the highest peak temperature since for cement-based materials higher curing temperatures (> 60 deg. C), while resulting in enhanced reaction kinetics and strength development for short curing durations (∼28 days), have been shown to adversely affect the physical properties of the material after extended cure times. In choosing representative profiles it is important to consider not only the maximum temperature, but also the influence of rate of temperature rise to the maximum temperature, and time at or close to the maximum temperature on the post-cured properties. The intent of this paper is to consider the varied curing temperature profiles to which the salt-stone is exposed in an SDU, and to analyze the currently available data for elevated temperature curing of salt-stone to determine the potential thermal effects on the saturated hydraulic conductivity of salt-stone emplaced in an SDU. This may subsequently facilitate a more informed approach to simulating the curing of salt-stone in a laboratory environment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mock-Up activities for the extraction of samples from a salt-stone disposal unit - 15502

Mock-up testing with respect to the core-drilling of simulant salt-stone grout was conducted to support the future retrieval of field-emplaced salt-stone samples from salt-stone Disposal Unit (SDU) Cell 2A. The primary objectives of extracting samples from SDU Cell 2A are to enable measurement of field-emplaced samples with respect to properties that influence long-term performance, such as saturated hydraulic conductivity, and to compare the measured properties for field-emplaced and comparable samples prepared in the laboratory. Initial mock-up activities (Phases 1 and 2) were conducted in Fiscal Years (FY) 2013 and 2014 in order to demonstrate the viability of standard core-drilling techniques that are typically employed for sampling concrete structures. The primary requirement for the core-drilling technique was that it should minimize the potential of physical or chemical sample changes that would artificially degrade key grout properties. Mock-up activities were aimed at optimizing the techniques for core-drilling, and subsequent sample extraction, using a set-up that mimicked, to the extent practical, both the physical characteristics, and operational complexities, of core-drilling salt-stone grout from the roof of the SDU. Samples extracted from the grout monolith were subsequently characterized with respect to saturated hydraulic conductivity and compressive strength, and compared to data for cast samples prepared using the same simulant salt-stone material. The comparison of these properties for the two sample types was expected to highlight potential flaws (e.g., micro-cracking) introduced by the core-drilling process. While the data for saturated hydraulic conductivity were virtually identical (approximately 2 E-09 cm/sec), the compressive strength of the core-drilled samples (approximately 3.5 MPa (500 psi)) was on average half that measured for the cast samples. It was suspected that increased water saturation and surface scoring of the core-drilled samples might account for the disparate compressive Strength data. During Phases 1 and 2 it was determined that cores could be successfully drilled and extracted to a depth of approximately 0.9 meters (3 feet) below the grout surface. Phase 3 (FY 2105) has been initiated and is primarily directed at demonstrating the ability to core-drill through approximately 1.8 meters (6 feet) of overlying grout to retrieve the desired sample from the SDU. The original drill depth of 0.6 - 0.9 meters (2-3 feet) was based on an SDU fill height of 5.6 meters (18.5 feet) and sample location of approximately 4.9 meters (16 feet); recently the allowable fill height in the SDUs has been increased to 6.5 meters (21.25 feet); hence the increased depth of overlying grout above the samples to be retrieved. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗