Ultra efficient turbo-compression cooling systems

Aspects of the present disclosure include a system for turbo-compression cooling. The system may be aboard a marine vessel. The system includes a power cycle and a cooling cycle. The power cycle includes a first working fluid, a waste heat boiler configured to evaporate the working fluid, a turbine, and a condenser. The condenser condenses the working fluid to a saturated or subcooled liquid. The cooling cycle includes a second working fluid, a first compressor configured to increase the pressure of the second working fluid, a condenser configured to condense the second working fluid to a saturated or subcooled liquid after exiting the first compressor, an expansion valve, and an evaporator. The turbine and first compressor are coupled one to the other. The waste heat boiler receives waste heat from engine jacket water and lubricating oil from a ship service generator. The evaporator cools water in a shipboard cooling loop.

Bandhauer, Todd M.↗

An experimentally validated evaporative phase change heat transfer model for low mass flux applications using R134a in plate heat exchangers

Plate frame heat exchangers are common in liquid-coupled vapor compression systems due to their compactness and ease of maintenance. In some of these systems, the refrigerant within the evaporator can enter the heat exchanger as a subcooled liquid. As a result, the refrigerant passes through three different phases: single-phase liquid, two-phase fluid, and a superheated vapor. Unfortunately, there have been limited prior studies that have identified the best method to predict performance under these circumstances. Furthermore, previous investigations have not evaluated refrigerant evaporation in large industrial sized plate frame heat exchangers under conditions experienced in the present study experimental test facility, especially at mass fluxes below 7 kg m –2 s –1 . In the present investigation, a model was developed to predict the performance of plate and frame heat exchangers when the fluid enters as a subcooled liquid and exits as a superheated vapor. The model used full-sized plate heat exchanger geometry that was discretized into 20 sections to accurately capture local heat transfer and pressure drop effects. The model was validated using an R134a counter flow heat exchanger used in a turbo-compression cooling system test facility that had subcooled liquid entering the evaporator at low mass fluxes. A variety of empirical correlations were evaluated to determine what combination yielded the best predictive capability over the following range of conditions: 5.8 < G < 6.8 kg m –2 s –1 , 2 < q” < 2.8 kW m –2 , and 10 °C < T sat < 15 °C. When the correlations used a fixed control volume length in the heat flux calculation, the most accurate combination resulted in a mean absolute error of 5.5%. Finally, future studies can use the approach described here to optimize heat exchanger size and performance.

42 ENGINEERING↗