An instrument to measure the spectrum of cosmic ray iron and other nuclei to above 100 GeV/nucleon

A balloon-borne instrument system for the study of cosmic ray composition in the energy region beyond 100 GeV/nucleon is described. The large area detector incorporates an ionization spectrometer or calorimeter to determine the energy of the incident particles which is calibrated in flight by a gas Cerenkov counter filled with freon 12 at 20 psi. Calibration of calorimeter response indicates that the effects of ionization energy loss and nucleon fragmentation are correctly accounted for in a Monte Carlo simulation. A charge measuring module consisting of five scintillators and a lucite Cerenkov counter is used to determine the charge and position of the incoming particles. A spatial resolution of 5 to 10 cm has been obtained by using the ratios of pulse heights in different photomultiplier tubes aimed at the same scintillators within the module. The detector represents the heaviest cosmic ray experiment that can be flown over 30 km using the dynamic launching technique commonly employed.

Arens, J. F.↗

An instrument to measure the spectrum of cosmic ray iron and other nuclei to above 100 GeV-nucleon

A balloon-borne detector system for extending the study of cosmic ray composition to the energy region beyond 100 GeV/nucleon is described. The instrument incorporates an ionization calorimeter and a gas Cherenkov counter filled with freon for the determination of energies, and a charge module, consisting of scintillation and a lucite Cherenkov counter, for determining the charge of the incoming particle. The scintillators were utilized to determine the position of the incoming particle in addition to its charge. The characteristics of these detectors with respect to resolution, and the methods employed in laboratory calibration, cross-checks with flight data and actual performance in the flights are described in detail. Monte Carlo simulation of the ionization calorimeter and comparison of the response of the calorimeter and gas Cherenkov counter for complex nuclei was used to convert the observed calorimeter signal to absolute energy in a consistent manner.

Arens, J. F.↗

High energy cosmic ray iron spectrum experiment

An instrument containing a gas Cerenkov counter and an iron ionization spectrometer was constructed in order to measure the cosmic-ray iron spectrum to 300 GeV/nucleon. Trajectories of particles were determined by entopistic or position-determining scintillator systems. The geometric factors with and without the gas Cerenkov counter were 0.3 and 0.6 sq m-ster, respectively. The instrument was successfully flown in June 1976 without the spectrometer and in October 1976 with the spectrometer from Palestine, Texas. The June flight yielded 14.5 h of data; the October flight, 25 h.

Arens, J. F.↗

Entopistic scintillators

Trajectories of cosmic rays through a balloon-borne experiment will be determined by pulse height analyzing the signals from each of the two or more phototubes coupled to each scintillator. Thin or tapered scintillators produce sufficiently strong gradients of phototube signal with respect to scintillation position that position uncertainties of about 1 cm can be achieved over 1-sq-m areas. Calculations and some test results for entopistic, or position determining, scintillators are presented.

Arens, J. F.↗

Astrophysical implications of the isotopic composition of cosmic rays

This paper considers some of the astrophysical consequences of recent cosmic-ray isotope measurements in the charge range between 4 and 26 for energies of 200 to 600 MeV/amu. Using a simple exponential path-length propagation model, the isotopic and chemical compositions are extrapolated observed back to the cosmic-ray source. With the possible exception of neon, all the results are consistent with the current understanding of cosmic-ray propagation and source composition. Some implications of the isotopic data as to the nature of the source are discussed.

Maehl, R.↗

Optical transmission measurements on monocrystalline and polycrystalline cesium iodide

A summary is presented of optical measurements performed on a variety of cesium iodide samples to characterize quantitatively the optical quality of the materials, and to define and measure parameters which determine its suitability as a detector material for high energy cosmic ray experiments on HEAO-A. The general case of light transmission through a long rectangular slab under multiple internal reflections is discussed along with transmission and scattering as a function of wavelength at normal incidence. Scattering parameters are tabulated for encapsulated single crystal CsI and polyscin.

Viehmann, W.↗

A search for lunar outgassing.

Lunar outgassing existence, recommending restriction of observation to narrow wavelength and search for water vapor bursts

Condon, J. J.↗