Search NASASearch

Engineering topics

Simonsen, Lisa C.

Publications and source records attributed to Simonsen, Lisa C..

At least 37 records · Page 2

Human factors evaluation of the HL-20 full-scale model

The human factors testing of the HL-20 personnel launch system full-scale model was conducted in both the vertical and horizontal positions at NASA Langley Research Center. Three main areas of testing were considered: an anthropometric fit evaluation, the ingress and egress of a 10-person crew, and pilot viewing. The subjects, ranging from the 5th to 95th percentile size, had sufficient clearance in the model, with the exception of the last two rows of seats and the cockpit area. Adjustable seat heights and/or placement of the seats farther forward would provide more headroom. In the horizontal position, the model's seat placement and aisle width allowed a quick and orderly 10-person egress for the no-keel (a structural support running the length on the aisle), 6-in.-high keel, and 12-in.-high keel conditions. Egress times were less than 20 s. For the vertical position, the model's long cylindrical shape with the ladder in the ceiling allowed a quick and orderly egress with average times less than 30 s. Ingress and egress procedures were demonstrated using Shuttle partial-pressure suits. The reduced mobility experienced while wearing the suits did increase egress times, although they still remained acceptable. The window arrangement for pilot viewing was found to be reasonably acceptable, although slight modifications, such as an increased downward view, is desirable.

Willshire, Kelli F.

Exposure fluctuations of astronauts due to orientation

The dose incurred in an anisotropic environment depends on the orientation of the astronaut's body relative to the direction of the radiation field. The fluctuations in exposure of specific organs due to astronaut orientation are found to be a factor of 2 or more in a typical space habitation module and typical space radiations. An approximation function is found that overestimates astronaut exposure in most cases studied and is recommended as a shield design guide for future space missions.

Wilson, John W.

Transport methods and interactions for space radiations

This report presents a brief history leading to the involvement of the Langley Research Center of the National Aeronautics and Space Administration (NASA) in space-radiation physics and protection. Indeed, a relatively complete summary of technical capability as of the summer of 1990 is given. The Boltzmann equations for coupled ionic and neutronic fields are presented and inversion techniques for the Boltzmann operator are discussed. Errors generated by the straight ahead approximation are derived and are shown to be negligible for most problems of space-radiation protection. A decoupling of projectile propagation from the target fields greatly simplifies the Boltzmann equations and allows an analytic solution of the target fragment transport. Analytic and numerical methods of solving the projectile transport equations are discussed. The nuclear physics underlying the coefficients in the Boltzmann equation is discussed. A coupled-channel optical model is found as a consequence of the loose binding of nuclear matter and closure of the nuclear states in high-energy reactions. Transport solutions with the developed data base are used with laboratory experiments to validate both the transport code and the data base. Numerical benchmarks and comparison with Monte Carlo calculations are also used for code validation.

Wilson, John W.

Solar particle dose rate buildup and distribution in critical body organs

Human body organs have varying degrees of radiosensitivity as evidenced by radioepidemiologic tables. The major critical organs for both the male and female that have been identified include the lung, thyroid, stomach, and breast (female). Using computerized anatomical models of the 50th percentile United States Air Force male and female, we present the self-shielding effects of these various body organs and how the shielding effects change as the location (dose point) in the body varies. Several major solar proton events from previous solar cycles and several events from the current 22nd solar cycle have been analyzed. The solar particle event rise time, peak intensity, and decay time vary considerably from event to event. Absorbed dose and dose equivalent rate calculations and organ risk assessment data are presented for each critical body organ. These data are compared with the current NASA astronaut dose limits as recommended by the National Council on Radiation Protection and Measurements.

Atwell, William

Radiation exposure predictions for short-duration stay Mars missions

The human radiation environment for several short-duration stay manned Mars missions is predicted using the Mission Radiation Calculation program, which was developed at NASA Langley Research Center. This program provides dose estimates for Galactic cosmic rays (GCR) and large and ordinary solar proton flare events for various amounts of effective spacecraft shielding and a given time history of the spacecraft's heliocentric position. The results of this study show that most of the missions can survive the most recent large flares if a 25 g/sq cm storm shelter is assumed. The dose predictions show that missions during solar minima are not necessarily the minimum dose cases, due to increased GCR contribution during this time period. The direct transfer mission studied has slightly lower doses than the outbound Venus swingby mission, with the greatest dose differences for the assumed worst case scenario. The GCR dose for a mission can be reduced by having the crew spend some fraction of its day nominally in the storm shelter.

Striepe, Scott A.

Radiation dose to critical body organs for October 1989 proton event

The Geostationary Operational Environmental Satellite (GOES-7) provides high-quality environmental data about the temporal development and energy characteristics of the protons emitted during a solar particle event. The GOES-7 time history of the hourly averaged integral proton flux for various particle kinetic energies are analyzed for the solar proton event occurring October 19-29, 1989. This event is similar to the August 1972 event that has been widely studied to estimate free-space and planetary radiation-protection requirements. By analyzing the time-history data, the dose rates, which can vary over many orders of magnitude in the early phases of the flare, can be estimated as well as the cumulative dose as a function of time. When basic transport results are coupled with detailed body organ thickness distributions calculated with the Computerized Anatomical Man and Computerized Anatomical Female models, the dose rates and cumulative doses to specific organs can be predicted. With these results, the risks of cancer incidence and mortality are estimated for astronauts in free space protected by various water shield thicknesses.

Simonsen, Lisa C.

Conceptual design of a lunar base thermal control system

Space station and alternate thermal control technologies were evaluated for lunar base applications. The space station technologies consisted of single-phase, pumped water loops for sensible and latent heat removal from the cabin internal environment and two-phase ammonia loops for the transportation and rejection of these heat loads to the external environment. Alternate technologies were identified for those areas where space station technologies proved to be incompatible with the lunar environment. Areas were also identified where lunar resources could enhance the thermal control system. The internal acquisition subsystem essentially remained the same, while modifications were needed for the transport and rejection subsystems because of the extreme temperature variations on the lunar surface. The alternate technologies examined to accommodate the high daytime temperatures incorporated lunar surface insulating blankets, heat pump system, shading, and lunar soil. Other heat management techniques, such as louvers, were examined to prevent the radiators from freezing. The impact of the geographic location of the lunar base and the orientation of the radiators was also examined. A baseline design was generated that included weight, power, and volume estimates.

Simonsen, Lisa C.

Lunar Habitat Would Be Assembled In Space

Conceptual lunar habitat built inside external tank from National Space Transportation System (NSTS). Tank modified in low Earth orbit using existing structures and openings for access without compromising structural integrity. Designed for unmanned transport to orbit around Moon, and autonomous soft landing. Houses crew of 12 for 70 days between resupply missions.

King, Charles B.

Radiation exposure predictions for long-duration-stay Mars missions

In this study, the ionizing radiation environment is estimated, using the Mission Radiation Calculation (MIRACAL) program, for several long-duration-stay Mars missions proposed for early in the 21st century. Both long-fast and minimum energy transfer missions are evaluated, and their 30-day maximum, annual maximum, and total slab skin and blood-forming organ (BFO) doses are compared. When large flares were included while the astronauts were on the surface, the delivered dose did not significantly contribute to the total dose (less than 4 cSv BFO dose, or 8 percent of the guideline annual limit, for the most energetic event simulated) due to the substantial protection provided by the Martian atmosphere. However, dose delivered by large flares during transit is dependent on vehicle shielding and distance from the sun. All of the long-fast transfer missions studied had lower total and annual maximum doses than the corresponding minimum energy transfer missions (on average, 30 percent less for missions having no large flares and the shielding thicknesses evaluated in this study). For all the missions studied, having the astronauts spend one-third of their day during transit in a 10 g/sq cm storm shelter resulted in significantly lower total doses.

Striepe, Scott A.

Concepts and strategies for lunar base radiation protection - Prefabricated versus in-situ materials

The most recently accepted environment data are used as inputs for the Langley nucleon and heavy-ion transport codes, BRYNTRN and HZETRN, to examine the shield effectiveness of lunar regolith in comparison with commercially-used shield materials in nuclear facilities. Several of the fabricated materials categorized as neutron absorbers exhibit favorable characteristics for space radiation protection. In particular, polyethylene with additive boron is analyzed with regard to response to the predicted lunar galactic cosmic ray and solar proton flare environment during the course of a complete solar cycle. Although this effort is not intended to be a definitive trade study for specific shielding recommendations, attention is given to several factors that warrant consideration in such trade studies. For example, the transporting of bulk shield material to the lunar site as opposed to regolith-moving and processing equipment is assessed on the basis of recent scenario studies. The transporting of shield material from Earth may also be a viable alternative to the use of regolith from standpoints of cost-effectiveness, EVA time required, and risk factor.

Simonsen, Lisa C.

MIRACAL: A mission radiation calculation program for analysis of lunar and interplanetary missions

A computational procedure and data base are developed for manned space exploration missions for which estimates are made for the energetic particle fluences encountered and the resulting dose equivalent incurred. The data base includes the following options: statistical or continuum model for ordinary solar proton events, selection of up to six large proton flare spectra, and galactic cosmic ray fluxes for elemental nuclei of charge numbers 1 through 92. The program requires an input trajectory definition information and specifications of optional parameters, which include desired spectral data and nominal shield thickness. The procedure may be implemented as an independent program or as a subroutine in trajectory codes. This code should be most useful in mission optimization and selection studies for which radiation exposure is of special importance.

Nealy, John E.

Method of providing a lunar habitat from an external tank

A lunar habitat is provided by placing an external tank of an orbiter in a low Earth orbit where the hydrogen tank is separated from the intertank and oxygen tank which form a base structure. The base structure is then outfitted with an air lock, living quarters, a thermal control system, an environmental control and life support system, and a propulsion system. After the mounting of an outer sheath about the base structure to act as a micrometeoroid shield, the base structure is propelled to a soft landing on the moon. The sheath is mounted at a distance from the base structure to provide a space therebetween which is filled with regolith after landing. Conveniently, a space station is used to outfit the base structure. Various elements of the oxygen tank and intertank are used in outfitting.

King, Charles B.

Mars surface radiation exposure for solar maximum conditions and 1989 solar proton events

The Langley heavy-ion/nucleon transport code, HZETRN, and the high-energy nucleon transport code, BRYNTRN, are used to predict the propagation of galactic cosmic rays (GCR's) and solar flare protons through the carbon dioxide atmosphere of Mars. Particle fluences and the resulting doses are estimated on the surface of Mars for GCR's during solar maximum conditions and the Aug., Sep., and Oct. 1989 solar proton events. These results extend previously calculated surface estimates for GCR's at solar minimum conditions and the Feb. 1956, Nov. 1960, and Aug. 1972 solar proton events. Surface doses are estimated with both a low-density and a high-density carbon dioxide model of the atmosphere for altitudes of 0, 4, 8, and 12 km above the surface. A solar modulation function is incorporated to estimate the GCR dose variation between solar minimum and maximum conditions over the 11-year solar cycle. By using current Mars mission scenarios, doses to the skin, eye, and blood-forming organs are predicted for short- and long-duration stay times on the Martian surface throughout the solar cycle.

Simonsen, Lisa C.

Transport methods and interactions for space radiations

A review of the program in space radiation protection at the Langley Research Center is given. The relevant Boltzmann equations are given with a discussion of approximation procedures for space applications. The interaction coefficients are related to solution of the many-body Schroedinger equation with nuclear and electromagnetic forces. Various solution techniques are discussed to obtain relevant interaction cross sections with extensive comparison with experiments. Solution techniques for the Boltzmann equations are discussed in detail. Transport computer code validation is discussed through analytical benchmarking, comparison with other codes, comparison with laboratory experiments and measurements in space. Applications to lunar and Mars missions are discussed.

Wilson, John W.

Solar flare protection for manned lunar missions - Analysis of the October 1989 proton flare event

Several large solar proton events occurred in the latter half of 1989. For a moderately shielded spacecraft in free space, the potential exposure would have been greatest for the flare which occurred between October 19 to 27, 1989. The temporal variations of the proton energy spectra at approximately 1 AU were monitored by the GOES-7 satellite. These data, recorded and processed at the NOAA-Boulder Space Environment Laboratory, provide the opportunity to analyze dose rates and cumulative doses which might be incurred by astronaus in transit to, or on, the moon. Of particular importance in such an event is the time development of exposure in the early phases of the flare, for which dose rates may range over many orders of magnitude in the first few hours. The cumulative dose as a function of time for the entire event is also predicted. In addition to basic shield calculations, dose rate contours are constructed for flare shelters in free-space and on the lunar surface.

Simonsen, Lisa C.

Subsystems component definitions summary program

A computer program, the Subsystems Component Definitions Summary (SUBCOMDEF), was developed to provide a quick and efficient means of summarizing large quantities of subsystems component data in terms of weight, volume, resupply, and power. The program was validated using Space Station Freedom Program Definition Requirements Document data for the internal and external thermal control subsystem. Once all component descriptions, unit weights and volumes, resupply, and power data are input, the user may obtain a summary report of user-specified portions of the subsystem or of the entire subsystem as a whole. Any combination or all of the parameters of wet and dry weight, wet and dry volume, resupply weight and volume, and power may be displayed. The user may vary the resupply period according to individual mission requirements, as well as the number of hours per day power consuming components operate. Uses of this program are not limited only to subsystem component summaries. Any applications that require quick, efficient, and accurate weight, volume, resupply, or power summaries would be well suited to take advantage of SUBCOMDEF's capabilities.

Scott, A. Don

Radiation protection for human missions to the Moon and Mars

Radiation protection assessments are performed for advanced Lunar and Mars manned missions. The Langley cosmic ray transport code and the nucleon transport code are used to quantify the transport and attenuation of galactic cosmic rays and solar proton flares through various shielding media. Galactic cosmic radiation at solar maximum and minimum, as well as various flare scenarios are considered. Propagation data for water, aluminum, liquid hydrogen, lithium hydride, lead, and lunar and Martian regolith (soil) are included. Shield thickness and shield mass estimates required to maintain incurred doses below 30 day and annual limits (as set for Space Station Freedom and used as a guide for space exploration) are determined for simple geometry transfer vehicles. On the surface of Mars, dose estimates are presented for crews with their only protection being the carbon dioxide atmosphere and for crews protected by shielding provided by Martian regolith for a candidate habitat.

Simonsen, Lisa C.

Radiation exposure and dose estimates for a nuclear-powered manned Mars sprint mission

A conceptual manned mission to Mars is analyzed in order to estimate potential ionizing radiation doses that may be incurred by crew members during the course of the mission. The scenario is set for a journey during the solar active period and includes a brief stay on the Martian surface. Propulsion is assumed to be provided by nuclear thermal rocket power, and estimates of the dose contributions from the reactors are included. However, due to effective shielding of the reactors by large propellant tanks, it is found that the incurred doses are principally due to the charged particle natural environment. Recent data (August-December 1989) for large solar proton events are used to simulate the flame environment, while standard models are used for the trapped particle and galactic cosmic ray contributions. Shield effectiveness for several candidate materials are investigated.

Nealy, John E.