Search NASA⌕ Search

Engineering topics

Simpson, A.

Publications and source records attributed to Simpson, A..

Simultaneous Millimeter-wave, Gamma-Ray, and Optical Monitoring of the Blazar PKS 2326-502 during a Flaring State

Including millimeter-wave data in multiwavelength studies of the variability of active galactic nuclei (AGN) can provide insights into AGN physics that are not easily accessible at other wavelengths. We demonstrate in this work the potential of cosmic microwave background (CMB) telescopes to provide long-term, high-cadence millimeter-wave AGN monitoring over large fractions of sky. We report on a pilot study using data from the SPTpol instrument on the South Pole Telescope (SPT), which was designed to observe the CMB at arcminute and larger angular scales. Between 2013 and 2016, SPTpol was used primarily to observe a single 500 deg2 field, covering the entire field several times per day with detectors sensitive to radiation in bands centered at 95 and 150 GHz. We use SPT 150 GHz observations to create AGN light curves, and we compare these millimeter-wave light curves to those at other wavelengths, in particular γ-ray and optical. In this Letter, we focus on a single source, PKS 2326-502, which has extensive, day-timescale monitoring data in gamma-ray, optical, and now millimeter-wave between 2013 and 2016. We find PKS 2326-502 to be in a flaring state in the first 2 yr of this monitoring, and we present a search for evidence of correlated variability between millimeter-wave, optical R-band, and γ-ray observations. This pilot study is paving the way for AGN monitoring with current and upcoming CMB experiments such as SPT-3G, Simons Observatory, and CMB-S4, including multiwavelength studies with facilities such as Vera C. Rubin Observatories Large Synoptic Survey Telescope.

79 ASTRONOMY AND ASTROPHYSICS↗

Passive Neutron Non-Destructive Assay for Remediation of Radiological Waste at Hanford Burial Grounds- 13189

The Hanford burial grounds contains a broad spectrum of low activity radioactive wastes, transuranic (TRU) wastes, and hazardous wastes including fission products, byproduct material (thorium and uranium), plutonium and laboratory chemicals. A passive neutron non-destructive assay technique has been developed for characterization of shielded concreted drums exhumed from the burial grounds. This method facilitates the separation of low activity radiological waste containers from TRU waste containers exhumed from the burial grounds. Two identical total neutron counting systems have been deployed, each consisting of He-3 detectors surrounded by a polyethylene moderator. The counts are processed through a statistical filter that removes outliers in order to suppress cosmic spallation events and electronic noise. Upon completion of processing, a 'GO / NO GO' signal is provided to the operator based on a threshold level equivalent to 0.5 grams of weapons grade plutonium in the container being evaluated. This approach allows instantaneous decisions to be made on how to proceed with the waste. The counting systems have been set up using initial on-site measurements (neutron emitting standards loaded into surrogate waste containers) combined with Monte Carlo modeling techniques. The benefit of this approach is to allow the systems to extend their measurement ranges, in terms of applicable matrix types and container sizes, with minimal interruption to the operations at the burial grounds. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Method for Optimizing Waste Management and Disposal Practices Using a Group-Based Uncertainty Model for the Analysis of Characterization Data - 13191

It is a universal requirement for characterization of radioactive waste, that the consignor shall calculate and report a Total Measurement Uncertainty (TMU) value associated with each of the measured quantities such as nuclide activity. For Non-destructive Assay systems, the TMU analysis is typically performed on an individual container basis. However, in many cases, the waste consignor treats, transports, stores and disposes of containers in groups for example by over-packing smaller containers into a larger container or emplacing containers into groups for final disposal. The current standard practice for container-group data analysis is usually to treat each container as independent and uncorrelated and use a simple summation / averaging method (or in some cases summation of TMU in quadrature) to define the overall characteristics and associated uncertainty in the container group. In reality, many groups of containers are assayed on the same system, so there will be a large degree of co-dependence in the individual uncertainty elements. Many uncertainty terms may be significantly reduced when addressing issues such as the source position and variability in matrix contents over large populations. The systematic terms encompass both inherently 'two-directional' random effects (e.g. variation of source position) and other terms that are 'one-directional' i.e. designed to account for potential sources of bias. An analysis has been performed with population groups of a variety of non-destructive assay platforms in order to define a quantitative mechanism for waste consignors to determine overall TMU for batches of containers that have been assayed on the same system. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗