Search NASA⌕ Search

Engineering topics

Sims, Cianan

Publications and source records attributed to Sims, Cianan.

At least 19 records

HyRAM+ (Hydrogen Plus Other Alternative Fuels Risk Assessment Models) v.5.1.1

HyRAM+ is a software toolkit for conducting quantitative risk assessment (QRA) and consequence modeling for hydrogen and other alternative fuels infrastructure and transportation systems. HyRAM+ contains validated, simplified release behavior models, a standardized QRA approach, and engineering models and generic data relevant to hydrogen installations. HyRAM (hydrogen-only) versions 1.0 to 3.1 were developed by Sandia for the U.S. Department of Energy (DOE) Hydrogen and Fuel Cell Technologies Office (HFTO). The U.S. DOE Vehicle Technologies Office (VTO) and U.S. Department of Transportation (DOT) Pipeline and Hazardous Material Safety Administration (PHMSA) contributed to the development of HyRAM+ version 4.0 regarding the addition of methane (natural gas) and propane models. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. SAND2021-10862 O

Groth, Katrina↗

Hydrogen Extremely Low Probability of Rupture Version 1

SAND2024-08511O The Hydrogen Extremely Low Probability of Rupture (HELPR) software toolkit provides probabilistic fracture assessments of natural gas infrastructure for transporting hydrogen. Using probabilistic sampling and sensitivity analysis—along with engineering fatigue and fracture mechanics— the software develops models that can predict structural integrity measures for natural gas pipelines under stress. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Schroeder, Benjamin↗

HyRAM+ (Hydrogen Plus Other Alternative Fuels Risk Assessment Models) v.4.1.1

HyRAM+ is a software toolkit for conducting quantitative risk assessment (QRA) and consequence modeling for hydrogen and other alternative fuels infrastructure and transportation systems. HyRAM+ contains validated, simplified release behavior models, a standardized QRA approach, and engineering models and generic data relevant to hydrogen installations. HyRAM (hydrogen-only) versions 1.0 to 3.1 were developed by Sandia for the U.S. Department of Energy (DOE) Hydrogen and Fuel Cell Technologies Office (HFTO). The U.S. DOE Vehicle Technologies Office (VTO) and U.S. Department of Transportation (DOT) Pipeline and Hazardous Material Safety Administration (PHMSA) contributed to the development of HyRAM+ version 4.0 regarding the addition of methane (natural gas) and propane models. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. SAND2021-10862 O

Groth, Katrina↗

HyRAM+ (Hydrogen Plus Other Alternative Fuels Risk Assessment Models) v.4.0

HyRAM+ is a software toolkit for conducting quantitative risk assessment (QRA) and consequence modeling for hydrogen and other alternative fuels infrastructure and transportation systems. HyRAM+ contains validated, simplified release behavior models, a standardized QRA approach, and engineering models and generic data relevant to hydrogen installations. HyRAM (hydrogen-only) versions 1.0 to 3.1 were developed by Sandia for the U.S. Department of Energy (DOE) Hydrogen and Fuel Cell Technologies Office (HFTO). The U.S. DOE Vehicle Technologies Office (VTO) and U.S. Department of Transportation (DOT) Pipeline and Hazardous Material Safety Administration (PHMSA) contributed to the development of HyRAM+ version 4.0 regarding the addition of methane (natural gas) and propane models. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. SAND2021-10862 O

Groth, Katrina↗

HyRAM (Hydrogen Risk Assessment Models) v. 2.0

HyRAM is a software toolkit for conducting quantitative risk assessment (QRA) and consequence modeling for hydrogen infrastructure and transportation systems. HyRAM contains validated, simplified hydrogen behavior models, a standardized QRA approach, and engineering models and generic data relevant to hydrogen installations. HyRAM 1.0 was developed by Sandia National Laboratories for the U. S. Department of Energy. SAND2019-5270 M

Groth, Katrina↗

Tower Illuminance Model

TIM is a real-time interactive concentrating solar field simulation. TIM models a concentrating tower (receiver), heliostat field, and potential reflected glare based on user-specified parameters such as field capacity, tower height and location. TIM provides a navigable 3D interface, allowing the user to “fly” around the field to determine the potential glare hazard from off-target heliostats. Various heliostat aiming strategies are available for specifying how heliostats behave when in standby mode. Strategies include annulus, point-per-group, up-aiming and single-point-focus. Additionally, TIM includes an avian path feature for approximating the irradiance and feather temperature of a bird flying through the field airspace.

Ho, Clifford K.↗

Solar Glare Hazard Analysis Tool v. 4.0

SGHAT predicts the occurrence and intensity of glare caused by a user-specified solar panel array when viewed from one or more observation points. An interactive mapping interface is used to determine the latitude, longitude and elevation of the array and observation points. The presence and intensity of glare is then calculated along a given time interval throughout the year, based on the position of the sun. The potential ocular hazard is also reported. The maximum energy production of the solar array is also estimated so that alternative designs can be compared to determine the design that yields the most energy production while mitigating glare.

Ho, Clifford L.↗

Evaluation of Glare at the Ivanpah Solar Electric Generating System

The Ivanpah Solar Electric Generating System (ISEGS), located on I - 15 about 40 miles (60 km) south of Las Vegas, NV, consists of three power towers 459 ft (140 m) tall and over 170,000 reflective heliostats with a rated capacity of 390 MW. Reports of glare from the plant have been submitted by pilots and air traffic controllers and recorded by the Aviation Safety Reporting System and the California Energy Commission since 2013. Aerial and ground - based surveys of the glare were conducted in April, 2014, to identify the cause and to quantify the irradiance and potential ocular impact s of the glare . Results showed that the intense glare viewed from the airspace above ISEGS was caused by he liostats in standby mode that were aimed to the side of the receiver. Evaluation of the glare showed that the retinal irradiance and subtended source angle of the glare from the heliostats in standby were sufficient to cause significant ocular impact (pot ential for after - image) up to a distance of %7E6 miles (10 km), but the values were below the threshold for permanent eye damage . Glare from the receivers had a low potential for after - image at all ground - based monitoring locations outside of the site bound aries. A Letter to Airmen has been issued by the Federal Aviation Administration to notify pilots of the potential glare hazards. Additional measures to mitigate the potential impacts of glare from ISGES are also presented and discussed. This page intentionally left blank

14 SOLAR ENERGY↗