Quasi-microscope concept for planetary missions - Stereo

The quasi-microscope has been used for stereo pictures using a small aperture placed at the right and left over the entrance aperture. A 16-degree stereo view angle yields an enhanced stereo effect. When viewed upward through a transparent support, all grains come into focus. The technique may be used for determining mineral constituents on the basis of cleavage and fracture patterns, grain details, and surface slopes used in estimating single-particle albedo and the illumination of scattering profiles.

Burcher, E. E.

Automatic focus control for facsimile cameras

An electronic circuit for controlling the focus of facsimile cameras is described. The circuit consists of balanced a.c. amplifiers, two square law function generators, and a differential amplifier and power drive. The invention includes a method for maintaining the imaging sensor at the expected location of the focal plane as the facsimile camera scans a scene or terrain. A block diagram of the electronic circuitry is provided.

Sinclair, A. R.

Automatic focus control for facsimile camera

Focus control performs function of automatically focusing facsimile camera throughout object field being scanned. It does this by determining and adjusting focus of imaging sensor accordingly. Since facsimile camera images a scene by scanning discrete strips, it is possible to have entire three-dimensional scene in perfect focus at point of imaging by use of focus control.

Sinclair, A. R.

First-order optical analysis of a quasi-microscope for planetary landers

A first-order geometrical optics analysis of a facsimile camera augmented with an auxiliary lens as magnifier is presented. This concept, called quasi-microscope, bridges the gap between surface resolutions of the order of 1 to 10 mm which can be obtained directly with planetary lander cameras and resolutions of the order of 0.2 to 10 microns which can be obtained only with relatively complex microscopes. A facsimile camera was considered in the analysis; however, the analytical results can also be applied to television and film cameras. It was found that quasi-microscope resolutions in the range from 10 to 100 microns are obtainable with current state-of-the-art lander facsimile cameras. For the Viking lander camera having an angular resolution of 0.04 deg, which was considered as a specific example, the best achievable resolution would be about 20 microns. The preferred approach to increase the resolution of the quasi-microscope would be, if possible, through an increase in angular resolution of the camera. A twofold to threefold improvement in resolution could also be achieved with a special camera focus position, but this approach tends to require larger and heavier auxiliary optics.

Huck, F. O.

Laser communication system for controlling several functions at a location remote to the laser

A multichannel laser remote control system is described. The system is used in areas where radio frequency, acoustic, and hardware control systems are unsatisfactory or prohibited and where line of sight is unobstructed. A modulated continuous wave helium-neon laser is used as the transmitter and a 360 degree light collector serves as the antenna at the receiver.

Burcher, E. E.

Ablation sensor Patent

Ablation sensor for measuring surface ablation rate of material on vehicles entering earths atmosphere on entry into planetary atmospheres

Russell, J. M., III