Search NASA⌕ Search

Engineering topics

Singer, Brett C.

Publications and source records attributed to Singer, Brett C..

At least 55 records · Page 3

Pollutant Exposures from Natural Gas Cooking Burners: A Simulation-Based Assessment for Southern California

Background: Residential natural gas cooking burners (NGCBs) can emit substantial quantities of pollutants, and they are typically used without venting range hoods. Objective: We quantified pollutant concentrations and occupant exposures resulting from NGCB use in California homes. Methods: A mass-balance model was applied to estimate time-dependent pollutant concentrations throughout homes in Southern California and the exposure concentrations experienced by individual occupants. We estimated nitrogen dioxide (NO2), carbon monoxide (CO), and formaldehyde (HCHO) concentrations for 1 week each in summer and winter for a representative sample of Southern California homes. The model simulated pollutant emissions from NGCBs as well as NO2 and CO entry from outdoors, dilution throughout the home, and removal by ventilation and deposition. Residence characteristics and outdoor concentrations of NO2 and CO were obtained from available databases. We inferred ventilation rates, occupancy patterns, and burner use from household characteristics. We also explored proximity to the burner(s) and the benefits of using venting range hoods. Replicate model executions using independently generated sets of stochastic variable values yielded estimated pollutant concentration distributions with geometric means varying by < 10%. Results: The simulation model estimated that—in homes using NGCBs without coincident use of venting range hoods—62%, 9%, and 53% of occupants are routinely exposed to NO2, CO, and HCHO levels that exceed acute health-based standards and guidelines. NGCB use increased the sample median of the highest simulated 1-hr indoor concentrations by 100, 3,000, and 20 ppb for NO2, CO, and HCHO, respectively. Conclusions: Reducing pollutant exposures from NGCBs should be a public health priority. Simulation results suggest that regular use of even moderately effective venting range hoods would dramatically reduce the percentage of homes in which concentrations exceed health-based standards.

54 ENVIRONMENTAL SCIENCES↗

Addressing Kitchen Contaminants for Healthy, Low-Energy Homes

Cooking and cooking burners emit pollutants that can adversely affect indoor air quality in residences and significantly impact occupant health. Effective kitchen exhaust ventilation can reduce exposure to cooking-related air pollutants as an enabling step to healthier, low-energy homes. This report identifies barriers to the widespread adoption of kitchen exhaust ventilation technologies and practice and proposes a suite of strategies to overcome these barriers. The recommendations have been vetted by a group of industry, regulatory, health, and research experts and stakeholders who convened for two web-based meetings and provided input and feedback to early drafts of this document. The most fundamental barriers are (1) the common misconception, based on a sensory perception of risk, that kitchen exhaust when cooking is unnecessary and (2) the lack of a code requirement for kitchen ventilation in most US locations. Highest priority objectives include the following: (1) Raise awareness among the public and the building industry of the need to install and routinely use kitchen ventilation; (2) Incorporate kitchen exhaust ventilation as a requirement of building codes and improve the mechanisms for code enforcement; (3) Provide best practice product and use-behavior guidance to ventilation equipment purchasers and installers, and; (4) Develop test methods and performance targets to advance development of high performance products. A specific, urgent need is the development of an over-the-range microwave that meets the airflow and sound requirements of ASHRAE Standard 62.2.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pollutant exposures from unvented gas cooking burners: A Simulation-based Assessment for Southern California

Residential natural gas cooking burners (NGCBs) can emit substantial quantities of pollutants, and they are typically used without venting range hoods. In this study, LBNL researchers quantified pollutant concentrations and occupant exposures resulting from NGCB use in California homes.The simulation model estimated that—in homes using NGCBs without coincident use of venting range hoods -- 62%, 9%, and 53% of occupants are routinely exposed to NO 2 , CO, and HCHO levels that exceed acute health-based standards and guidelines. NGCB use increased the sample median of the highest simulated 1-hr indoor concentrations by 100, 3,000, and 20 ppb for NO 2 , CO, and HCHO, respectively. The study recommends that reducing pollutant exposures from NGCBs should be a public health priority. Simulation results suggest that regular use of even moderately effective venting range hoods would dramatically reduce the percentage of homes in which concentrations exceed health-based standards.

03 NATURAL GAS↗

Addressing Kitchen Contaminants for Healthy, Low-Energy Homes

Cooking and cooking burners emit pollutants that can adversely affect indoor air quality in residences and significantly impact occupant health. Effective kitchen exhaust ventilation can reduce exposure to cooking-related air pollutants as an enabling step to healthier, low-energy homes. This report by Lawrence Berkeley National Laboratory identifies barriers to the widespread adoption of kitchen exhaust ventilation technologies and practice and proposes a suite of strategies to overcome these barriers. The recommendations have been vetted by a group of industry, regulatory, health, and research experts and stakeholders who convened for two meetings and provided input and feedback to early drafts of this document. The most fundamental barriers are (1) the common misconception, based on a sensory perception of risk, that kitchen exhaust when cooking is unnecessary and (2) the lack of a code requirement for kitchen ventilation in most U.S. locations. Highest priority objectives include the following: (1) Raise awareness among the public and the building industry of the need to install and routinely use kitchen ventilation; (2) Incorporate kitchen exhaust ventilation as a requirement of building codes and improve the mechanisms for code enforcement; (3) Provide best practice product and use-behavior guidance to ventilation equipment purchasers and installers, and; (4) Develop test methods and performance targets to advance development of high performance products. A specific, urgent need is the development of an over-the-range microwave that meets the airflow and sound requirements of ASHRAE Standard 62.2.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Impacts of Energy and Indoor Environmental Quality Retrofits of Apartments in California

Monthly gas and electricity use data from a set of 13 study apartments and 20 control apartments from three apartment buildings (B1 B3) in California were analyzed. The study apartments were retrofit with simultaneous energy savings and indoor environmental quality (IEQ) improvements as the goal. The control apartments were not retrofit. Pre-retrofit modeling indicated annual energy savings of 21percent, 17percent, and 27percent for the study apartments in B1-B3, respectively. Based on a comparison of changes in energy use of study apartments to energy use changes of control apartments, total measured savings of gas energy plus site electrical energy were 28percent in B1, 5percent in B2, and 3percent in B3. Given the small number of study apartments and the substantial changes in energy use within control apartments, the project yielded no conclusive evidence of energy savings. Apartment energy use increased with number of occupants and with floor area; however, the association with occupancy was most evident. Climate differences did not appear to be the major driver for the variability in energy use among apartments. Changes in occupant behaviors affecting energy use may have overwhelmed and obscured the energy savings in this small number of buildings. Much larger prior studies employing similar retrofits indicate that the retrofits usually do save energy.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Participant Assisted Data Collection Methods in the California Healthy Homes Indoor Air Quality Study of 2011-13

From November 2011 to March 2013, air quality was measured over 6-day periods in 324 residences across California using a mail-out strategy. All interactions with study participants, from recruitment, to data collection, to communication of results, were conducted with remote communication methods including conventional mail, electronic mail, telephone and text messaging. Potential participants were reached primarily by sharing study information with community groups and organizations that directed interested individuals to complete an online screening survey. Pollutant concentrations were measured with sampling equipment that was mailed to participants’ homes with deployment instructions. Residence and household characteristics and activity data were collected via two phone surveys and an activity log. A comparison of responses to survey questions completed online versus over the phone indicated that a substantial fraction of participants (roughly 20%) required a researcher’s assistance to respond to basic questions about appliance characteristics. Using the printed instructions and telephone assistance from researchers, roughly 90% of participants successfully deployed and returned sampling materials accurately and on schedule. The mail-out strategy employed in this study was found to be a cost-effective means for collecting residential air quality data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Participant Assisted Data Collection Methods in the California Healthy Homes Indoor Air Quality Study of 2011-13

From November 2011 to March 2013, air quality was measured over 6-day periods in 324 residences across California using a mail-out strategy. All interactions with study participants, from recruitment, to data collection, to communication of results, were conducted with remote communication methods including conventional mail, electronic mail, telephone and text messaging. Potential participants were reached primarily by sharing study information with community groups and organizations that directed interested individuals to complete an online screening survey. Pollutant concentrations were measured with sampling equipment that was mailed to participants' homes with deployment instructions. Residence and household characteristics and activity data were collected via two phone surveys and an activity log. A comparison of responses to survey questions completed online versus over the phone indicated that a substantial fraction of participants (roughly 20%) required a researcher's assistance to respond to basic questions about appliance characteristics. Using the printed instructions and telephone assistance from researchers, roughly 90% of participants successfully deployed and returned sampling materials accurately and on schedule. The mail-out strategy employed in this study was found to be a cost-effective means for collecting residential air quality data.

54 ENVIRONMENTAL SCIENCES↗

Indoor Environmental Quality Benefits of Apartment Energy Retrofits

Sixteen apartments serving low-income populations in three buildings were retrofit with the goal of simultaneously reducing energy consumption and improving indoor environmental quality (IEQ). Retrofit measures varied among apartments and included, among others, envelope sealing, installation of continuous mechanical ventilation systems, upgrading bathroom fans and range hoods, attic insulation, replacement of heating and cooling systems, and adding wall-mounted particle air cleaners. IEQ parameters were measured, generally for two one-week periods before and after the retrofits. The measurements indicate an overall improvement in IEQ conditions after the retrofits. Comfort conditions, bathroom humidity, and concentrations of carbon dioxide, acetaldehyde, volatile organic compounds, and particles generally improved. Formaldehyde and nitrogen dioxide levels decreased in the building with the highest concentrations, were unchanged in a second building, and increased in a third building. IEQ parameters other than particles improved more in apartments with continuous mechanical ventilation systems installed. In general, but not consistently, larger percent increases in air exchange rates were associated with larger percent decreases in indoor levels of the pollutants that primarily come from indoor sources.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Protocol for maximizing energy savings and indoor environmental quality improvements when retrofitting apartments

The current focus on building energy retrofit provides an opportunity to simultaneously improve indoor environmental quality (IEQ). Toward this end, we developed a protocol for selecting packages of retrofits that both save energy and improve IEQ in apartments. The protocol specifies the methodology for selecting retrofits from a candidate list while addressing expected energy savings, IEQ impacts, and costs in an integrated manner. Interviews, inspections and measurements are specified to collect the needed input information. The protocol was applied to 17 apartments in three buildings in two different climates within California. Diagnostic measurements and surveys conducted before and after retrofit implementation indicate enhanced apartment performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Predicting Backdrafting and Spillage for Natural-Draft Gas Combustion Appliances: Validating VENT-II

VENT-II is a computer program designed to provide detailed analysis of natural draft and induced draft combustion appliance vent-systems (i.e., furnace or water heater). This program is capable of predicting house depressurization thresholds that lead to backdrafting and spillage of combustion appliances; however, validation reports of the program being applied for this purpose are not readily available. The purpose of this report is to assess VENT-II’s ability to predict combustion gas spillage events due to house depressurization by comparing VENT-II simulated results with experimental data for four appliance configurations. The results show that VENT-II correctly predicts depressurizations resulting in spillage for natural draft appliances operating in cold and mild outdoor conditions, but not for hot conditions. In the latter case, the predicted depressurizations depend on whether the vent section is defined as part of the vent connector or the common vent when setting up the model. Overall, the VENTII solver requires further investigation before it can be used reliably to predict spillage caused by depressurization over a full year of weather conditions, especially where hot conditions occur.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ventilation Control of Volatile Organic Compounds in New U.S. Homes: Results of a Controlled Field Study in Nine Residential Units

In order to optimize strategies to remove airborne contaminants in residences, it is necessary to determine how contaminant concentrations respond to changes in the air exchange rate. The impact of air exchange rate on the indoor concentrations of 39 target volatile organic compounds (VOCs) was assessed by measuring air exchange rates and VOC concentrations at three ventilation settings in nine residences. Active sampling methods were used for VOC concentration measurements, and passive perfluorocarbon tracer gas emitters with active sampling were used to determine the overall air exchange rate corresponding to the VOC measurements at each ventilation setting. The concentration levels and emission rates of the target VOCs varied by as much as two orders of magnitude across sites. Aldehyde and terpene compounds were typically the chemical classes with highest concentrations, followed by alkanes, aromatics, and siloxanes. For each home, VOC concentrations tended to decrease as the air exchange rate was increased, however, measurement uncertainty was significant. The indoor concentration was inversely proportional to air exchange rate for most compounds. For a subset of compounds including formaldehyde, however, the indoor concentration exhibited a non-linear dependence on the timescale for air exchange.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ventilation Control of Volatile Organic Compounds in New U.S. Homes: Results of a Controlled Field Study in Nine Residential Units

In order to optimize strategies to remove airborne contaminants in residences, it is necessary to determine how contaminant concentrations respond to changes in the air exchange rate. The impact of air exchange rate on the indoor concentrations of 39 target volatile organic compounds (VOCs) was assessed by measuring air exchange rates and VOC concentrations at three ventilation settings in nine residences. Active sampling methods were used for VOC concentration measurements, and passive perfluorocarbon tracer gas emitters with active sampling were used to determine the overall air exchange rate corresponding to the VOC measurements at each ventilation setting. The concentration levels and emission rates of the target VOCs varied by as much as two orders of magnitude across sites. Aldehyde and terpene compounds were typically the chemical classes with highest concentrations, followed by alkanes, aromatics, and siloxanes. For each home, VOC concentrations tended to decrease as the air exchange rate was increased, however, measurement uncertainty was significant. The indoor concentration was inversely proportional to air exchange rate for most compounds. For a subset of compounds including formaldehyde, however, the indoor concentration exhibited a non-linear dependence on the timescale for air exchange

42 ENGINEERING↗

Impact of Natural Gas Appliances on Pollutant Levels in California Homes

This report presents results from the first year of a 2-year study, investigating associations of five air pollutants (CO, NO 2 , NO X , formaldehyde and acetaldehyde) with the presence of natural gas appliances in California homes. From November 2011 to March 2012, pollutant concentration and occupant activity data were collected in 155 homes for 6-day periods. The sample population included both single-family (68%) and multi-family (32%) dwellings, with 87% having at least one gas appliance and 77% having an unvented gas cooking appliance. The geometric mean (GM) NO 2 levels measured in the kitchen, bedroom and outside of homes were similar at values of 15, 12 and 11 ppb, respectively. In contrast, the GM NO X levels measured in the kitchen and bedroom of homes were much higher than levels measured outdoors, at levels of 42 and 41 ppb, compared to 19 ppb, respectively. Roughly 10% of sampled homes had 6-day average NO2 levels that exceeded the outdoor annual average limit set by the California Ambient Air Quality Standards (CAAQS) (30 ppb). The GMs of the highest 1-h and 8-h CO level measured in homes were 2.5 and 1.1 ppm, respectively. Four homes had a 1-h or 8-h concentration that exceeded the outdoor limits set by the CAAQS. The GM formaldehyde and acetaldehyde concentrations measured in homes were 15 and 7 ppb, respectively. Roughly 95% of homes had average formaldehyde levels indoors that exceeded the Chronic Reference Exposure Level set by the California EPA (7 ppb). Concentrations of NO 2 and NO X , and to a lesser extent CO were associated with use of gas appliances, particularly unvented gas cooking appliances. Based on first principles, it is expected that effective venting of cooking pollutant emissions at the source will lead to a reduction of pollutant concentrations. However, no statistical association was detected between kitchen exhaust fan use and pollutant concentrations in homes in this study where gas cooking occurred frequently. The lack of statistical

03 NATURAL GAS↗

Evaluation of Miscellaneous and Electronic Device Energy Use in Hospitals

Miscellaneous and electronic loads (MELs) consume about one-thirdof the primary energy used in US buildings, and their energy use is increasing faster than other end-uses. In healthcare facilities, 30percent of the annual electricity was used by MELs in 2008. This paper presents methods and challenges for estimating medical MELs energy consumption along with estimates of energy use in a hospital by combining device-level metered data with inventories and usage information. An important finding is that common, small devices consume large amounts of energy in aggregate and should not be ignored when trying to address hospital energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗