Hydrodynamics of countercurrent flow in an additive-manufactured column with triply periodic minimal surfaces for carbon dioxide capture

Computational investigation of the countercurrent flows in an additively manufactured (AM) column packed with triply periodic minimal surface (TPMS) is challenging. Multiphase flow simulations using the volume of fluid (VOF) method can explain the column’s hydrodynamic characteristics, including interfacial area, liquid holdup, pressure drop, flow regime, etc. The interfacial area is a key factor dictating the mass transfer via the absorption process, and thereby the overall efficiency of the column. The impacts of a solvent's physical properties, liquid and gas loads, and contact angle on the hydrodynamics are extensively explored. The solvents include traditional solvent (monoethanolamine [MEA]) used in industry as well as a water-lean solvent (EEMPA) as prospective solvents for carbon capture. As expected, interfacial area and liquid holdup increase with increasing liquid loads (q L ). The EEMPA exhibits higher values for the interfacial area and liquid holdup compared to those for the MEA. The dry and wet pressure drops per unit length in the column at different gas loads (F G ) are calculated and further compared with the empirical correlations for traditional packings. At low gas loads, i.e., in the preloading regime, the predicted values of the wet and dry pressure drops match well with the corresponding values calculated from available correlations. The gas load has a marginal impact on the interfacial area at its lower value, but the higher value of F G (>2.18 $\sqrt{Pa}$) causes flooding in the column. The effect of varying contact angles on the interfacial area and liquid holdup in the preloading regime is also studied. Both interfacial area and liquid holdup decrease with the increase in the value of the contact angle. Altogether, the effect of the contact angle on interfacial area is more pronounced than other parameters influencing the interfacial area.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The influence of random packed column parameters on the liquid holdup and interfacial area

Abstract Carbon dioxide capture via solvent absorption in packed columns has emerged as a potential technology to mitigate coal‐fired power plant CO 2 emissions. Parameters, including packing types, solvent properties, and operating conditions, could potentially affect the packed column CO 2 capture efficiency. To understand the importance of those parameters and help packed column optimization, a design of experiments (DoEs) method was proposed to generate input parameter matrix. Combined with multiphase computational fluid dynamics (CFD), the random packed column parameter influence on the liquid holdup and interfacial area can be efficiently investigated. Surrogate‐based sensitivity analysis shows that the solvent flow rate and contact angle are key factors dictating liquid holdup and interfacial area. On the other hand, solvent viscosity has a marginal impact on the interfacial area. The sensitivity scores were calculated for each input parameter to guide the selection of dimensionless numbers for the liquid holdup and interfacial area correlation development.

42 ENGINEERING↗

EARLY BUD-BREAK 1 and EARLY BUD-BREAK 3 control resumption of poplar growth after winter dormancy

Bud-break is an economically and environmentally important process in trees and shrubs from boreal and temperate latitudes, but its molecular mechanisms are poorly understood. Here, we show that two previously reported transcription factors, EARLY BUD BREAK 1 (EBB1) and SHORT VEGETATIVE PHASE-Like (SVL) directly interact to control bud-break. EBB1 is a positive regulator of bud-break, whereas SVL is a negative regulator of bud-break. EBB1 directly and negatively regulates SVL expression. We further report the identification and characterization of the EBB3 gene. EBB3 is a temperature-responsive, epigenetically-regulated, positive regulator of bud-break that provides a direct link to activation of the cell cycle during bud-break. EBB3 is an AP2/ERF transcription factor that positively and directly regulates CYCLIND3.1 gene. Our results reveal the architecture of a putative regulatory module that links temperature-mediated control of bud-break with activation of cell cycle.

54 ENVIRONMENTAL SCIENCES↗

Hydrodynamics of countercurrent flows in a structured packed column: effects of initial wetting and dynamic contact angle

The structured packed column has gained considerable attention as a prospective technology to mitigate carbon dioxide emissions from thermal power plants. The computational flow investigation of such systems is a multiscale problem, and local hydrodynamics plays a key role in overall column efficiency. Accordingly, multiphase flow studies in the representative elementary unit (REU) of a packed column can offer insights into the local flow behavior such as flow pattern, interfacial area, etc. The interfacial area plays a key role in the overall interphase mass transfer and thereby in separation efficiency. The predicted effective area matches well with corresponding ones in experiments for Mellapak 250.Y packings. The contact angle (i.e., solid substrate behavior) is one of the critical factors that dictates wettings, and thereby the interfacial area. The dynamic contact angle (DCA) was considered in order to explore the effects of contact angle hysteresis on the interfacial area. DCA has more pronounced impact on the interfacial area for a solvent possessing a higher value of surface tension and equilibrium contact angle. The interfacial area shows temporal undulation and does not achieve a pseudo steady state due to the capillary force. In contrary, the interfacial area gets a net value for a solvent having low surface tension value. Further, specification of the static contact angle at the solid substrate shows the least value of the interfacial area. We also extensively studied the effect of the initial sheet condition (dry vs wet) on the interfacial area. The initially wetted sheets show slightly higher value of the interfacial area as compared to the initially dry sheets at a fixed flow rate for a solvent having high surface tension value. Wetting hysteresis decreases with increasing liquid loads. On the other hand, wetting hysteresis does not occur for a solvent having value of low surface tension and equilibrium contact angle.

structured packings, dynamic contact angle, interf↗

Absorber Column CFD model validation against PNNL’s device-scale absorber column on the LCFS unit

Absorber column has been widely used for CO 2 capture in the coal-fired power plants. High-fidelity CFD models play an important role in absorber column design and solvents optimization, which help enhance the CO 2 capture efficiency and reduce the operation cost. This report provides a comprehensive description of the development of CFD absorber models at two different levels, the design and implementation of PNNL’s device-scale absorber column experiment, and the methodology to combine the CFD results, experiment data, and Aspen model for a better understanding of the interface area in packed column. A composite model is firstly proposed in the Discrete Element Method (DEM) packing process, which can model the complex geometry of various packing elements. This generates a realistic packing pattern and accurate packing porosity ε and specific area a p compared to the actual values for absorber column used in LCFS. Two level of CFD absorber models were developed, namely the full-size column model (FCM) to simulate the entire packed column with a focus on the wall/entrance effects, and the representative column model (RCM) to simulate a section of column with a focus on the sensitivity study of interface area. A Design of Experiment (DoE) plan was developed to guide the collection of 100 run CFD data and 12 experiment runs. The 100 CFD runs were carried out in the RCM with Pro-Pak packing and cover a wide operation range and solvent properties. Impact of influential factors on the interface area in packed column were investigated in details. The CFD interface area was then combined with the experimental data and Aspen model to infer some information of the effective contact angle in the column. The accuracy and uncertainties in the interface area and contact angle can be quantified.