Singleton, Michael

Publications and source records attributed to Singleton, Michael.

Comparison of the sensitivity of 236 U measurements in environmental samples by MC-ICP-MS and ATONA based high precision U TIMS measurements

The ATONA project is focused upon exploring the improvements in uranium isotope ratio measurements by thermal ionization mass spectrometry (TIMS) provided by a new, capacitor-based, amplifier technology. These “ATONA” Faraday amplifiers (Isotopx Ltd, UK) promise accurate, low-noise measurements of very small signals (< 1 femto-amp) in a traditional Faraday cup, which was only previously possible using an ion counter. This report outlines a series of experiments that were performed to assess the performance of the system in samples that test our rapid analysis procedures, and then compare the results against other mass spectrometry techniques currently available for environmental analyses. The following major goals were achieved: (1) illustrated the importance of 236 U measurements for the screening and analysis of environmental samples; (2) improved sensitivity for 236 U, and then identified 236 U in the 4350B standard at ultra-trace levels (3) Provided comparison of the 236 U sensitivity to multi-collector inductively coupled mass spectrometry techniques (4) Illustrated high TRL for the ATONA based measurement technique. This completes the reporting requirements for task 4 in the project LCP and highlights the utility of the system to make highly sensitive 236 U measurements in programmatically relevant sample matrices and at relevant uranium concentrations.

07 ISOTOPE AND RADIATION SOURCES↗

Studies of Helium Behavior in Uranium Hexafluoride

Several issues have arisen from experimental observations and/or theoretical postulation related to the behavior of helium in uranium hexafluoride (UF 6 ) matrices and how it may impact the ability to use this noble gas to quantify the fill date of the cylinder. A series of experiments was conducted to address several such issues, and the results and implications are reported here. Two issues relate to bias in the helium measurement due to ambient air from extraneous sources such as atmospheric air or from potential holdup in a large, activated alumina chemical trap. These issues are really a question of differential retention of helium versus three other inert gas isotopes (representative of other noble gases found in air) used as a calibration for air in leakage. Discernable bias was not detected in either case. Another issue had to do with helium potentially brought into the cylinder by a liquid UF 6 fill and subsequently released as the material solidifies and/or during storage. The solubility of helium in liquid UF 6 was measured to investigate this theory. The experiment quantified the potential magnitude of the initial helium contribution if present. The final issue was that of retention of helium in solid UF 6 . Investigation of this theory necessitated quantifying both the solubility and the diffusivity of helium in UF 6 . In one experiment, the solubility was measured at cryogenic temperature, allowing quantification of helium in solid UF 6 such as would be found in a cold trap. In a second experiment, transport of helium into and through a macroscopic plug of solid UF 6 was examined. The transport was very slight although apparently detectible. Effectively, only an upper limit to the transport could be determined, but that limit implied that helium holdup in solid UF 6 is a real possibility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The oxygen stable isotope composition of CRM 125-A UO 2 standard reference material

While there is a clear need for standardized reference materials for analytical calibrations and for inter-laboratory comparisons, there are not currently any for the oxygen stable isotopic composition of uranium oxides. In this paper we summarize the results from four laboratories by seven different methods of oxygen stable isotope analyses using fluorination techniques of CRM 125-A UO 2 Standard Reference Material. We synthesize these data and methods to arrive at a consensus oxygen stable isotope composition for CRM 125-A $δ$ 18 O = -9.63‰ (±0.29‰) VSMOW. We discuss methodological differences between analytical approaches, including furnace vs laser heating, fluorination using BrF 5 or ClF 3 , as well as calibration strategies. We highlight the potential effects of calibration scale compression from single-point calibrations using reference material with $δ$ 18 O values having a large relative difference from the sample being analyzed. We demonstrate how calibration scale compression can yield differences in calibrated $δ$ 18 O values up to ~2‰ for samples with ~20‰ difference from a single reference material, if the calibration slope of different analytical systems differs by 0.1. In conclusion, we suggest the use of liquid water calibration standards sealed in silver capillary tubes for multi-point calibrations of fluorination analysis systems.

07 ISOTOPE AND RADIATION SOURCES↗