Search NASA⌕ Search

Engineering topics

Sinn, H

Publications and source records attributed to Sinn, H.

Time-dependent wave front propagation simulation of a hard x-ray split-and-delay unit: Towards a measurement of the temporal coherence properties of x-ray free electron lasers

For the European x-ray free electron laser (XFEL) a split-and-delay unit based on geometrical wavefront beam splitting and multilayer mirrors is built which covers the range of photon energies from 5 keV up to 20 keV. Maximum delays between Δτ = ±2.5 ps at hν=20 keV and up to Δτ = ±23 ps at hν = 5 keV will be possible. Time-dependent wave-optics simulations have been performed by means of Synchrotron Radiation Workshop software for XFEL pulses at hν = 5 keV. The XFEL radiation was simulated using results of time-dependent simulations applying the self-amplified spontaneous emission code FAST. Main features of the optical layout, including diffraction on the beam splitter edge and optics imperfections measured with a nanometer optic component measuring machine slope measuring profiler, were taken into account. The impact of these effects on the characterization of the temporal properties of XFEL pulses is analyzed. An approach based on fast Fourier transformation allows for the evaluation of the temporal coherence despite large wavefront distortions caused by the optics imperfections. In this manner, the fringes resulting from time-dependent two-beam interference can be filtered and evaluated yielding a coherence time of τ c = 0.187 fs (HWHM) for real, nonperfect mirrors, while for ideal mirrors a coherence time of τ c = 0.191 fs (HWHM) is expected.

36 MATERIALS SCIENCE↗

Coherence Properties of Individual Femtosecond Pulses of an X-ray Free-Electron Laser

Measurements of the spatial and temporal coherence of single, femtosecond x-ray pulses generated by the first hard x-ray free-electron laser, the Linac Coherent Light Source, are presented. Single-shot measurements were performed at 780 eV x-ray photon energy using apertures containing double pinholes in 'diffract-and-destroy' mode. We determined a coherence length of 17 {micro}m in the vertical direction, which is approximately the size of the focused Linac Coherent Light Source beam in the same direction. The analysis of the diffraction patterns produced by the pinholes with the largest separation yields an estimate of the temporal coherence time of 0.55 fs. We find that the total degree of transverse coherence is 56% and that the x-ray pulses are adequately described by two transverse coherent modes in each direction. This leads us to the conclusion that 78% of the total power is contained in the dominant mode.

43 PARTICLE ACCELERATORS↗

Zone Plates for Hard X-Ray FEL Radiation

We investigated theoretically the use of zone plates for the focusing of the European X-ray Free Electron Laser (XFEL). In a finite-element simulation the heat load on zone plates placed in the high intensity x-ray beam was simulated for four different zone plate materials: gold, iridium, tungsten, and CVD diamond. The main result of the calculations is that all zone plates remain below the melting temperature throughout a full XFEL pulse train of 3000 pulses. However, if the zone plate is placed in the direct beam it will experience large and rapid temperature fluctuations on the order of 300 K. The situation is relaxed if the optic is placed behind a monochromator and the fluctuations are reduced to around 20 K. Besides heat load, the maximization of the total efficiency of the complete optical system is an important issue. We calculated the efficiency of different zone plates and monochromator systems and found that the final beam size of the XFEL in combination with its monochromaticity will be important parameters.

43 PARTICLE ACCELERATORS↗

New developments in fabrication of high-energy-resolution analyzers for inelastic x-ray spectroscopy.

In this work new improvements related to the fabrication of spherical bent analyzers for 1 meV energy-resolution inelastic X-ray scattering spectroscopy are presented. The new method includes the use of a two-dimensional bender to achieve the required radius of curvature for X-ray analyzers. The advantage of this method is the ability to monitor the focus during bending, which leads to higher-efficiency analyzers.

43 PARTICLE ACCELERATORS↗

Focusing of millijoule picosecond K{sub a}lpha radiation from 100 TW laser-solid interaction

A calibrated x-ray spectrometer was used to characterize an intense 4.5 keV K{sub a}lpha source. Generated from the interaction of 30 J-320 fs laser pulses focused on 25 mum thick Ti foils, the conversion efficiency into Ti K{sub a}lpha line is estimated to (9+-6)x10{sup -5}. Highly efficient collection, monochromatization and focusing were achieved using an ellipsoidally bent highly oriented pyrolytic graphite crystal. The measured 700 mum full width half maximum (FWHM) focal spot leads to a fluence of (3.0+-2.1) mJ/cm{sup 2} hence paving the way to the study of intense x-ray pulse interaction with matter as demonstrated by a first simple experiment.

36 MATERIALS SCIENCE↗

Protein elasticity probed with two synchrotron-based techniques.

Compressibility characterizes three interconnecting properties of a protein: dynamics, structure, and function. The compressibility values for the electron-carrying protein cytochrome c and for other proteins, as well, available in the literature vary considerably. Here, we apply two synchrotron-based techniques - nuclear resonance vibrational spectroscopy and inelastic x-ray scattering - to measure the adiabatic compressibility of this protein. This is the first report of the compressibility of any material measured with this method. Unlike the methods previously used, this novel approach probes the protein globally, at ambient pressure, does not require the separation of protein and solvent contributions to the total compressibility, and uses samples that contain the heme iron, as in the native state. We show, by comparing our results with molecular dynamics predictions, that the compressibility is almost independent of temperature. We discuss potential applications of this method to other materials beyond proteins.

59 BASIC BIOLOGICAL SCIENCES↗

Momentum-resolved resonant and nonresonant inelastic x-ray scattering at the Advanced Photon Source.

The study of electronic excitations by inelastic X-ray scattering (IXS) has a rich history. Very early IXS work, for example, provided seminal demonstrations of the validity of relativistic kinematics and the quantum hypothesis and of Fermi-Dirac statistics. While there have been many important results in the interim, it has been the development of the third generation light sources together with continuing innovations in the manufacture and implementation of dispersive X-ray optics that has led to the rapid growth of IXS studies of electronic excitations.

43 PARTICLE ACCELERATORS↗

Damage of amorphous carbon induced by soft x-ray femtosecond pulses above and below the critical angle

We present results of damage studies conducted at the Free Electron LASer in Hamburg (FLASH) facility with 13.5 nm (91.8 eV) and 7 nm (177.1 eV) radiations. The laser beam was focused on a sample of 890-nm-thick amorphous carbon coated on a silicon wafer mimicking a x-ray mirror. The fluence threshold for graphitization was determined for different grazing angles above and below the critical angle. The observed angular dependence of F{sub th} is explained by the variation in absorption depth and reflectivity. Moreover, the absorbed local dose needed for the phase transition leading to graphitization is shown to vary with the radiation wavelength.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Liquid boron: x-ray measurements and ab initio molecular dynamics simulations.

We report results of a comprehensive study of liquid boron with x-ray measurements of the atomic structure and dynamics coupled with ab initio molecular dynamics simulations. There is no evidence of survival into the liquid of the icosahedral arrangements that characterize the crystal structures of boron but many atoms appear to adopt a geometry corresponding to the pentagonal pyramids of the crystalline phases. Despite similarities in the melting behavior of boron and silicon, there is little evidence of a significant structural shift with temperature that might suggest an eventual liquid-liquid phase transition. Relatively poor agreement with the observed damping of the sound excitations is obtained with the simple form of mode-coupling theory that has proved successful with other monatomic liquids, indicating that higher-order correlation functions arising from directional bonding and short-lived local structures are playing a crucial role. The large ratio of the high frequency to the isothermal sound velocity indicates a much stronger viscoelastic stiffening than in other monatomic liquids.