Search NASA⌕ Search

Engineering topics

Sinsheimer, John

Publications and source records attributed to Sinsheimer, John.

Quantum Efficiency Enhancement of Bialkali Photocathodes by an Atomically Thin Layer on Substrates

Quantum efficiency (QE) enhancement in accelerator technology relevant to antimonide photocathodes (K 2 CsSb) is achieved by interfacing them with atomically thin 2D crystal layers. The enhancement occurs in a reflection mode, when a 2D crystal is placed in between the photocathodes and optically reflective substrates. Specifically, the peak QE at 405 nm (3.1 eV) increases by a relative 10%, whereas the long wavelength response at 633 nm (2.0 eV) increases by a relative 36% on average and up to 80% at localized “hot spot” regions when photocathodes are deposited onto graphene–coated stainless steel. There is a similar effect for photocathodes deposited on hexagonal boron nitride monolayer coatings using nickel substrates. The enhancement does not occur when reflective substrates are replaced with optically transparent sapphire. Optical transmission, X–ray diffraction (XRD), and X–ray fluorescence (XRF) revealed that thickness, crystal orientation, quality, and elemental stoichiometry of photocathodes do not appreciably change due to 2D crystal coatings. Furthermore these results suggest that optical interactions are responsible for the QE enhancements when 2D crystal sublayers are present on reflective substrates, and provide a pathway toward a simple method of QE enhancement in semiconductor photocathodes by an atomically thin 2D crystal on substrates.

43 PARTICLE ACCELERATORS↗

Free-Standing Bialkali Photocathodes Using Atomically Thin Substrates

This study reports successful deposition of high quantum efficiency (QE) bialkali antimonide K2CsSb photocathodes on graphene films. The results pave the way for an ultimate goal of encapsulating technologically relevant photocathodes for accelerator technology with an atomically thin protecting layer to enhance lifetime while minimizing QE losses. A QE of 17% at approximate to 3.1 eV (405 nm) is the highest value reported so far on graphene substrates and is comparable to that obtained on stainless steel and nickel reference substrates. The spectral responses of the photocathodes on graphene exhibit signature features of K2CsSb including the characteristic absorption at approximate to 2.5 eV. Materials characterization based on X-ray fluorescence and X-ray diffraction reveals that the composition and crystal quality of these photocathodes deposited on graphene is comparable to those deposited on a reference substrate. Quantitative agreement between optical calculations and QE measurements for the K2CsSb on free suspended graphene and a graphene-coated metal substrate further confirms the high-quality interface between the photocathodes and graphene. Finally, a correlation between the QE and graphene quality as characterized by Raman spectroscopy suggests that a lower density of atomistic defects in the graphene films leads to higher QE of the deposited K2CsSb photocathodes.

accelerator technology↗

The Tynode: A new vacuum electron multiplier

By placing, in vacuum, a stack of transmission dynodes (tynodes) on top of a CMOS pixel chip, a single free electron detector could be made with outstanding performance in terms of spatial and time resolution. The essential object is the tynode: an ultra thin membrane, which emits, at the impact of an energetic electron on one side, a multiple of electrons at the other side. The electron yields of tynodes have been calculated by means of GEANT-4 Monte Carlo simulations, applying special low-energy extensions. The results are in line with another simulation based on a continuous charge-diffusion model. By means of Micro Electro Mechanical System (MEMS) technology, tynodes and test samples have been realized. The secondary electron yield of several samples has been measured in three different setups. Finally, several possibilities to improve the yield are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fabrication and testing of a newly designed slit system for depth-resolved X-ray diffraction measurements

A new system of slits called `spiderweb slits' have been developed for depth-resolved powder or polycrystalline X-ray diffraction measurements. The slits act on diffracted X-rays to select a particular gauge volume of sample, while absorbing diffracted X-rays from outside of this volume. Although the slit geometry is to some extent similar to that of previously developed conical slits or spiral slits, this new design has advantages over the previous ones in use for complex heterogeneous materials and in situ and operando diffraction measurements. For example, the slits can measure a majority of any diffraction cone for any polycrystalline material, over a continuous range of diffraction angles, and work for X-ray energies of tens to hundreds of kiloelectronvolts. The design is generated and optimized using ray-tracing simulations, and fabricated through laser micromachining. The first prototype was successfully tested at the X17A beamline at the National Synchrotron Light Source, and shows similar performance to simulations, demonstrating gauge volume selection for standard powders, for all diffraction peaks over angles of 2–10°. A similar, but improved, design will be implemented at the X-ray Powder Diffraction beamline at the National Synchrotron Light Source II.

depth-resolved↗