Search NASA⌕ Search

Engineering topics

Sirota, Dana

Publications and source records attributed to Sirota, Dana.

Low Yield Nuclear Monitoring Physics Experiment 1 – Integrated Data Acquisition System Design and Initial Observations

The report documents the design of the Integrated Data AcQuisition (IDAQ) system and observations recorded during the first in a series of underground chemical explosions conducted on the Nevada National Security Site (NNSS) in southern Nevada. Experiments are funded as part of Low Yield Nuclear Monitoring (LYNM) research and development within the United States National Nuclear Security Administration NA-22 nuclear non-proliferation program. The series is part of the broader Physical Experiment 1 (PE1) being conducted in and around the P-tunnel facility on the NNSS. Each explosive experiment utilizes several tons of comp-B to generate signals recorded by a broad suite of instrumentation. The IDAQ serves as the backbone for all subsurface instrumentation providing precise time synchronization, remote control, data exfiltration and backup, along with recording several sensing modalities throughout the underground complex that includes ground motion, environmental conditions, and electromagnetic signals.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Geophysical Imaging of Flow and Transport (GIFT): FY24 Status Report

The GIFT (Geophysical Imaging of Flow and Transport) system will improve predictive capabilities as a platform for collecting multi-physical (MP) time-lapse datasets from well-controlled laboratory experiments. This will enable more accurate prediction of multi-phase fluid flow during delivery and transport of insitu remedial amendments as important components of the overall Hanford Site cleanup mission. Design and construction of the GIFT system, which consists of a meter-scale test cell and a network of custom gas circulation and analysis systems, was accomplished in fiscal year (FY) 2024, with plans to add liquid circulation to the system and use this new capability for multi-phase deep vadose experiments starting in FY25.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

4D Electrical Resistivity Imaging of Stress Perturbations Induced During High–Pressure Shear Stimulation Tests

Fluid flow through fractured media is typically governed by the distribution of fracture apertures, which are in turn governed by stress. Consequently, understanding subsurface stress is critical for understanding and predicting subsurface fluid flow. Although laboratory–scale studies have established a sensitive relationship between effective stress and bulk electrical conductivity in crystalline rock, that relationship has not been extensively leveraged to monitor stress evolution at the field scale using electrical or electromagnetic geophysical monitoring approaches. In this paper we demonstrate the use time–lapse 3–dimensional (4D) electrical resistivity tomography to image perturbations in the stress field generated by pressurized borehole packers deployed during shear–stimulation attempts in a 1.25 km deep metamorphic crystalline rock formation.

58 GEOSCIENCES↗

Deep Vadose Zone Monitoring Test Bed (FY23 Status Report)

A subsurface air injection at the Hanford Site’s Deep Vadose Zone Monitoring Test Bed was completed to realize a change in subsurface hydrologic conditions in accordance with a soil desiccation remedy. The injection mimicked a previous injection at the site that was performed in accordance with a vadose zone treatability study. Unlike the previous test which relied on electrical methods only, the change in hydrologic conditions during the recent test was also monitored using cross-hole seismic sensing methods to assess the ability of the seismic methods to evaluate changes in moisture conditions of desiccated sediment at the field scale. Data from in situ neutron probes indicates a reduction of soil moisture in the vicinity of the injection well due to the air injection. Similar changes were observed in the time-lapse electrical resistivity and seismic data, which indicates a loss of soil moisture over time. Tomographic inversions of the time-lapse geophysical data illustrate the 2D and 3D features of the soil moisture distribution over time. Time-lapse electrical resistivity tomography (ERT) results show a reduction in the electrical conductivity of the subsurface in the vicinity of the injection well, with most changes occurring within the screened interval. Similar patterns are observed in the seismic tomography results, with both methods illustrating two lobe-shaped features of reduced soil moisture. Use of seismic and ERT technologies in tandem takes advantage of two complementary geophysical monitoring technologies, providing increased sensitivity to specific hydrologic conditions. The multiphysics approach, therefore, has the potential to improve the ability to estimate subsurface moisture conditions from sensor-based and remotely sensed geophysical data that will ultimately improve the ability of remediation contractors to evaluate remedy performance.

58 GEOSCIENCES↗

EGS Collab Experiment 2: Hydraulic Pressure Test Results

The EGS Collab experiment 2 was focused on testing shear stimulation techniques. Shear stimulation, in this case, means using hydraulic pressure to cause shear slip on preexisting fracture or fault planes such that the hydraulic conductivity of the fracture or fault increases. The concept is to create a percolating network of permeable fractures by enhancing the permeability of a primarily preexisting network of fractures. To test this concept the hydraulic pressures for experiment 2 were kept below the the estimated magnitude of the least compressive principal stress based on a set of stress measurements in nearby well TV4100. All tests for experiment 2 were performed by applying hydraulic pressure to well E2-TC. Subsequent stimulations in both E2-TC and E2-TU where the injection pressure was increased above the least compressive principal stress are considered part of experiment 3, which is documented separately. The data are organized in directories labeled by the depth range isolated between packers.

15 GEOTHERMAL ENERGY↗

Real-Time Seismic System for Monitoring, Imaging, and Characterization (RT-SEISMIC)

The goal of this Laboratory Directed Research and Development (LDRD) project was to develop a borehole seismic source and sensor array to enable real-time seismic imaging at scales and conditions relevant to the energy industry including both fossil-energy and geothermal. In FY21 and FY22, we designed, built, and tested both a prototype impulse source module for generating seismic energy and a sensing module for recording ground motions generated by the source module array. A pneumatically driven vibratory source was also designed. The source modules were fabricated with all high temperature components and the team has worked to incorporate the current RT-SEISMIC electronics design into a commercially available, high temperature silicon-on-insulator chip integrated circuit. Several issues were identified during fabrication and lab testing that led to redesign of several system components and subsequent retesting. The final round of testing showed that while metal/graphite-based seals worked quite well for static seals, they were unable to provide an adequate gas seal for dynamic, reciprocating part movements which necessitated a final redesign using Kalrez. This change will result in a continuous temperature rating of approximately 275 degrees C for the system. While a field test of the RT-SEISMIC system was targeted in FY22, due to the extended lab testing and redesign efforts, field testing was not achieved. As a result of this LDRD investment, several sponsors have expressed interest in RT-SEISMIC and we expect to continue towards a field demonstration of the full system in the future.

58 GEOSCIENCES↗

EGS Collab Experiment 3: 4100 Tensile Stimulation and Thermal Circulation Testing

These data and test descriptions are from a set of primarily tensile hydraulic-fracture stimulations in wells E2-TC and E2-TU and a subsequent chilled water circulation test conducted by injecting in well E2-TU on the 4100 level of the Sandford Underground Research Facility (SURF). Stimulations were carried out between April and May of 2022. The thermal circulation test ran semi-continuously from May 19 through August 26, 2022, though chilled water injection began on June 3. More information about the test, rationale, and processing of data is available on the EGS Collab project page, which is linked below.

15 GEOTHERMAL ENERGY↗

EGS Collab Experiment 2: Results of Tracer Tests

Multiple sets of tracer tests were conducted at the EGS Collab Testbed 2 on the 4100 L at the Sanford Underground Research Facility (SURF), Lead, SD. The enclosed data package includes: tracer recovery results, water balance calculations and rationales, water flow measurement for north ditch, (manual) water flow measurements at different production points, and a tracer-interpretation paper presented at the Stanford Geothermal Workshop, 2023.

15 GEOTHERMAL ENERGY↗