Skifton, Richard S.

Publications and source records attributed to Skifton, Richard S..

At least 19 records

Methods for making high-temperature thermocouples

Methods of manufacturing thermocouples having a first thermoelement wire comprises a molybdenum-lanthanum based material and a second thermoelement wire comprises a phosphorus-doped niobium, may involve exposing a first thermoelement wire and a second thermoelement wire to a temperature in a range extending from about 50° C. to about 60° C. above an intended operational temperature of the first and second thermoelement wires and until a rate of change of a normalized voltage output of the first thermoelement wire and the second thermoelement wire is about 0.001 normalized Volts per hour or less.

Skifton, Richard S.↗

Multi-core high-temperature, irradiation-resistant thermocouple, and related methods

A multi-core thermocouple includes a plurality of wires, an insulation core surrounding the plurality of wires, a sheath surrounding the insulation core, and a plurality of electrical junctions. The plurality of electrical junctions may include a first electrical junction formed between a first wire of the plurality of wires and the sheath at a first axial mid-section of the multi-core thermocouple, the first electrical junction including a first swaged axial mid-section of the sheath and a second electrical junction formed between a second wire of the plurality of wires and the sheath at a second, different axial mid-section of the multi-core thermocouple, the second electrical junction including a second swaged axial mid-section of the sheath.

Skifton, Richard S.↗

High-temperature, irradiation-resistant thermocouple, coaxial thermocouple, and related methods

A coaxial thermocouple includes a wire, an insulation layer surrounding the wire, a sheath surrounding the insulation layer, and an electrical junction formed between the wire and the sheath and at one longitudinal end of the coaxial thermocouple, the electrical junction including a swaged end with an outer diameter of the sheath reducing in diameter along a longitudinal length of the coaxial thermocouple until the sheath contacts the wire within the insulation layer. The wire includes a first material and the sheath includes a second material where the first material includes one of molybdenum (Mo) or niobium (Nb) and the second material includes the other of molybdenum (Mo) or niobium (Nb).

Skifton, Richard S.↗

Development and Test Results of Thermocouples Used in the TRISO-Fuel Irradiation Experiment AGR-5/6/7

High-temperature gas reactor irradiation experiments create unique challenges for thermocouple-based temperature measurements. High-temperature industrial thermocouples suffer rapid decalibration due to transmutation of the thermoelements from neutron absorption. For lower-temperature applications, Type K and Type N thermocouples are affected by neutron irradiation only to a limited extent. But until recently, the use of these nickel-based thermocouples was limited when the temperature exceeded 1050°C due to drift related to phenomena other than nuclear irradiation. Certain portions of the AGR-5/6/7 experiment experienced temperatures higher than any of the previous AGR tests, up to 1500°C. Recognizing the limitations of existing thermometry to measure such high temperatures, the sponsor of the AGR-5/6/7 test supported a development and testing program for thermocouples capable of low-drift operation at temperatures above 1100°C. This program included additional development of high-temperature irradiation-resistant thermocouples based on molybdenum/niobium thermoelements, which have been studied at Idaho National Laboratory since circa 2004. A step change in accuracy and long-term stability of this thermocouple type was achieved as part of the AGR-5/6/7 thermometry development program. Additionally, long-term testing (7000+ h) at 1250°C of Type N thermocouples utilizing a customized sheath developed at the University of Cambridge has been completed with excellent low-drift results. The results of this testing as well as testing of the improved high-temperature irradiation-resistant design are reported herein. Both the improved high-temperature irradiation-resistant and the Cambridge Type N thermocouple types were incorporated into the AGR-5/6/7 test, which began irradiation in February 2018 and was completed in July 2020. Finally, a summary of the performance of the thermocouples incorporated into the AGR-5/6/7 test is included herein.

In-pile instrumentation↗

Combined Experimental and Computational Study of Molybdenum and Niobium for Nuclear Sensor Application

Due to their novel electromagnetic and thermal properties, molybdenum (Mo) and niobium (Nb) become optimal temperature sensor materials for nuclear energy applications. We leveraged voltage recorded during a heat ramp to tune a computational method to predict the Seebeck electromotive force (EMF) of Mo and Nb. Using a combined Density Functional Theory (DFT) and Boltzmann Transport Equations (BTE) method the voltage was predicted but did not include the effects of temperature on atomic structure. Combining Ab Initio Molecular Dynamics (AIMD) and BTE included temperature effects on structure optimization and yielded voltages in a good agreement with experiment. Lanthanum (La) and Phosphorus (P) additives in Mo and Nb, respectively, could increase the EMF compared to those of the pure metals. The presence of oxygen (O) in Mo increases the EMF while O in Nb slightly reduces the EMF. Furthermore, our studies suggested that heat treatment-induced structural changes that lead to a reduction in voltage occur not only at the mesoscale as previously understood but also at the atomic scale.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermocouple Testing in Support of the AGR-5/6/7 Experiment

This report documents thermocouple testing performed in IRC Lab C-15 over a period of seven years. This testing supported selection and characterization of the thermocouple set used in the AGR-5/6/7 experiment. The following summary was taken directly from the report. Temperature measurement is a challenging aspect of very high temperature irradiation experiments because commonly used high-temperature commercial thermocouples such as platinum-rhodium (Types S, R, and B) and tungsten-rhenium (Type C), suffer dramatic drift because of neutron-induced transmutation. As a result, these types of thermocouples, which are used routinely for industrial temperature measurements outside of reactors, are used only in very special circumstances for reactor experiments. Conversely, because of their low neutron cross-sections, Type N thermocouples are affected to only a limited extent by neutron irradiation. However, the use of these nickel-based thermocouples is limited when the temperature exceeds 1050°C due to drift arising from minor alloying elements migrating from the thermocouple's metal sheath to the thermoelements. This change in the composition of the thermo-elements results in significant decalibration of the signal. The issues described above were recognized during the early planning stages of the final AGR experiment (designated AGR-5/6/7), and a thermocouple furnace testing program was performed over a seven-year period (2014-2019, 2021) to first select and then characterize the best thermocouple set for the high temperature regions of the AGR-5/6/7 irradiation experiment. The calculated temperature range of the AGR-5/6/7 experiment was 600–1500°C. For temperatures below 1000°C standard Type N thermocouples were deemed adequate. The furnace testing campaign identified two thermocouple types suitable for measuring temperatures above 1000°C, a Mo/Nb thermocouple developed at INL called HTIR-TC, and a Type N thermocouple developed by Cambridge University (called herein Cambridge Type N), which featured a custom high nickel alloy sheath. One of the original goals of the furnace testing program was to identify a thermocouple capable of low drift operation near the peak temperature expected in AGR-5/6/7, i.e., about 1400°C. The HTIR-TC design appeared promising in this regard, however a manufacturing difficulty proved to be a barrier and instead the furnace testing focused on drift performance at 1250°C. The manufacturing difficulty was that the Nb sheaths of the HTIR-TCs experienced extreme embrittlement when heat treated at 1600°C or greater. Heat treatment is needed to stabilize the emf output of this TC type, and the higher the heat treatment temperature the higher the peak temperature of stable operation. Because of the sheath embrittlement the heat treatment temperature had to be lowered to 1450°C resulting in a stable operating temperature of about 1250°C. One of the successes of the furnace testing program was identification of a shortcoming in the heat treatment procedure that had been traditionally used in the production of HTIR-TCs. The shortcoming was that the entire heated length of the HTIR-TC sensor was not being heat treated, but rather only the part of the sensor expected to experience temperatures above 1000°C. The problem manifested itself when the thermocouples were removed from the heat treat furnace and placed in another furnace with a different geometry, their indicated temperatures would be widely scattered, but mostly in the negative direction. The solution was to heat treat the entire heated length of the sensor. Since the deepest immersion depth in the AGR-5/6/7 experiment was about 40 inches, a heat treatment length of 48 inches was used. After this change was implemented, thermocouples which were moved into a new environment with a different temperature profile (i.e., a different furnace), produced accurate temperature measurements. Although assembly of the AGR-5/6/7 experiment was completed in September of 2017 (and irradiation begun in 2018), furnace testing of thermocouples continued in 2018 and 2019. The main purpose of this testing was to establish very long-term drift characteristics of the HTIR and Cambridge Type N thermocouples installed in the experiment. Representative thermocouples from the same lots as those installed in the AGR-5/6/7 experiment were used. Additionally, thermocouples of different designs, (particularly variations on the HTIR-TC design) were "piggy-backed" on this testing program to provide insights for instrumenting future very high temperature irradiation experiments. This two-year testing program demonstrated that HTIR-TCs and Cambridge Type N TCs could operate at 1250°C for up to 10,000 hrs (and in some cases longer) while experiencing negative drifts on the order of 2-4°C/1000 hrs. This performance was considered acceptable given the extreme operating environment the sensors faced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Additive Manufacturing of Miniaturized Peak Temperature Monitors for In-Pile Applications

Passive monitoring techniques have been used for peak temperature measurements during irradiation tests by exploiting the melting point of well-characterized materials. Recent efforts to expand the capabilities of such peak temperature detection instrumentation include the development and testing of additively manufactured (AM) melt wires. In an effort to demonstrate and benchmark the performance and reliability of AM melt wires, we conducted a study to compare prototypical standard melt wires to an AM melt wire capsule, composed of printed aluminum, zinc, and tin melt wires. The lowest melting-point material used was Sn, with a melting point of approximately 230 °C, Zn melts at approximately 420 °C, and the high melting-point material was aluminum, with an approximate melting point of 660 °C. Through differential scanning calorimetry and furnace testing we show that the performance of our AM melt wire capsule was consistent with that of the standard melt-wire capsule, highlighting a path towards miniaturized peak-temperature sensors for in-pile sensor applications.

36 MATERIALS SCIENCE↗

Sublimation temperature sensor for temperature locale

The sublimation temperature sensor (or “sublime sensor”) provides a continuum of measurement locations in which certain maximum temperatures are achieved during a heat up/cool down cycle. A predetermined material is encapsulated within a vacuum-sealed, non-volatile long tube (i.e., both ends capped and L$\gg$ D). This assembly is then inserted and centered into a heated zone, such as a furnace, exhaust pipe, or reactor. As the temperature increases, the material will sublimate (i.e., a process of having both the solid and gaseous states of matter simultaneously present) and will begin to fill the void - moving outward in both directions toward the ends of the tube. Once beyond the elevated temperatures, the gas will de-sublimate (i.e., deposition) onto the inner wall of the tube. The desired result of the sensor is the ring of material that develops over a relatively short period of time. This material deposit can be equated with temperature at an exact location. There is no need to interpolate and/or extrapolate for the desired measurement. Accuracy has been recorded for temperature locations on the range of ±2 mm over a 1 m span. Likewise, the precision of the measurement is ±0.2% the overall sensor domain. Furthermore, individual tubes with unique materials and pressures can be bundled together to provide a complete temperature profile of the heated zone.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temperature locale sensors and related methods

Temperature locale sensors include an enclosure defining a sealed volume with a phase-change material therein at a known pressure. The phase-change material is formulated to exhibit a gas-to-solid phase change, without condensing to a liquid phase, at the known pressure and a targeted temperature, i.e., the material's “deposition temperature.” The phase-change material—while at least partially in gaseous form, either initially or after sublimation—is exposed to an environment with temperatures varying by location, including a maximum temperature above the phase-change material's deposition temperature and other temperatures at or below the deposition temperature. The gaseous phase-change material, in a location at the deposition temperature, solidifies from its gaseous phase to form solid grain deposits on a surface within the enclosure of the sensor. The solid deposits precisely identify the location of the specific, targeted deposition temperature.

Skifton, Richard S.↗

Qualification Test Requirements Report for High-Temperature Irradiation-Resistant Thermocouples

The qualification of f high-temperature irradiation-resistant thermocouples (HTIR-TCs) is set forth utilizing the Advanced Gas Reactor (AGR) 5/6/7 test in the Advanced Test Reactor located at the Idaho National Laboratory (INL). The requirements to achieve the qualification are appropriate design, construction, and calibration followed by proper installation and performance parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Function and Operational Requirements for High-Temperature Irradiation-Resistant Thermocouples

The function and operation requirements for the high-temperature irradiation-resistant thermocouple (HTIR-TC) are set forth. A mission and product are proposed. The function and operational requirements involve temperature range, accuracy, drift, life, mechanical ruggedness, and response time. Each have a criterion set to establish a thermocouple that can withstand a typical 18-month nuclear power plant refueling cycle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Temperature Irradiation-Resistant Thermocouple Qualification (Test Results Report)

This is a qualification report for the high-temperature irradiation-resistant thermocouple (HTIR-TC) developed by Nuclear Energy Enabling Technologies Advanced Sensors and Instrumentation program. Utilizing the Advanced Gas Reactor (AGR) 5/6/7 test conducted in the Advanced Test Reactor (ATR) at Idaho National Laboratory, the HTIR-TCs measured temperatures upwards of 1500°C during accident conditions. The HTIR TCs are thus qualified to perform and withstand an 18-month refueling cycle typical of nuclear power plants at the normal operating temperature, with a drift of less than ±1%. The HTIR-TC is also qualified for incorporating into a test fixture during new fuels tests.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary Calibration System Report for High-Temperature Irradiation-Resistant Thermocouples

An established calibration procedure is presented for the high-temperature irradiation-resistant thermocouple (HTIR-TC). Standard calibration curves for both an individual (i.e. case by case basis) and common calibrations is shown. The error limits within ±3 σ are ±1% for the individual calibrations and ±2% for the common calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Out-of-pile performance of High Temperature Irradiation Resistant and Cladding Thermocouples

The High Temperature Irradiation Resistant thermocouple (HTIR-TCs) has proven to be the nuclear temperature sensor. It outlast and outperforms all other commercially available thermocouples above 1100 °C inside reactor pressure vessels; also, recent calibration methods have pushed the HTIR-TC to accurately read temperatures through thermal transients during reactor shutdowns and restarts. The new temperature range of HTIR-TCs is from 0 °C to 1650 °C. The main objective of this study is to address manufacturing a more robust TC for handling and inserting into reactor experiments; to also apply the TC to a wider application. The TC has shown to be mainly susceptible to oxygen levels inside the heat treatment and calibration process and it is recommended that O2 levels be brought to as low as possible. However, through modeling efforts the O2 has been found to intercalate only within the first few layers of niobium on the outer sheath. Lastly, multiple materials were used for the sheath and insulators; all with similar outcomes when testing occurred over a long period of time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Some observations concerning near-wall PTV measurements

In conjunction with an experimental study of entropy generation in bypass-transitional boundary layers, some considerations in the application of particle tracking velocimetry (PTV) have been examined. Treated are ideas on desirable spatial resolution, uncertainties in PTV algorithms and other uncertainties which may dominate plus the deduction of mean wall shear stress (or friction velocity) from mean velocity profiles determined with near-wall PTV.

47 OTHER INSTRUMENTATION↗

Performance of Custom-Made Very High Temperature Thermocouples in the Advanced Gas Reactor Experiment AGR-5/6/7 During Irradiation [Slides]

Three thermocouple types were incorporated into the AGR-5/6/7 experiment: HTIR-TC, Cambridge Type N, and standard Type N. Prior to selecting these thermocouples, a development and testing program was conducted, and improvements made to the HTIR-TC design. Partly because of the extreme temperatures, the experiment has experienced a relatively high thermocouple failure rate. However, all capsules had at least three surviving thermocouples at the end of four cycles. In the high temperature regions, the HTIR-TCs suffered a lower failure rate compared to Cambridge Type N. One HTIR-TC operated at 1450–1500°C for 85 days without observable drift, which we believe to be the highest sustained temperature ever recorded in a reactor experiment. Three other HTIR-TCs operated at 1250–1400°C, also without observable drift.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of Mock-up and Integration for Ultrasonic Deformation Sensor for TREAT Experiments

Fuel deformation (both axial and radial) information provides insights into fuel performance and failure limits. Traditionally, fuel deformation has been quantified using post-irradiation examinations due to the lack of an appropriate sensor for monitoring deformation in situ. Recent developments in sensor and instrumentation design have led to the use of linear variable differential transducers (LVDT) for monitoring axial strain in fuel during irradiation. Size and operational constraints limit the use of LVDT sensors for radial deformation monitoring, and alternatives are needed. One possible alternative to LVDT sensors is an ultrasonic sensor. Ultrasonic sensors monitor the interaction of high-frequency stress waves with the test object. The resulting response may be analyzed to determine the properties of the material, including stress, strain, microstructure, presence of defects, and the elastic constants. While ultrasonic measurements have been successfully applied for monitoring strain in a number of applications, their use for in-core measurements has been limited. Largely, the limitations are due to the challenges associated with designing sensors that can operate under typical in-core conditions. This report documents progress to date toward planning, construction, and testing of a mock-up test capsule/facility to be used for in-lab testing of ultrasonic displacement sensor designs and toward integration of the sensor into prototypic TREAT experiment designs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗