Search NASASearch

Engineering topics

Slaba, Tony C.

Publications and source records attributed to Slaba, Tony C..

At least 19 records

A Bi-Exponential Repair Algorithm for Radiation-Induced Double-Strand Breaks: Application to Chromosome Aberrations

Chromosome aberrations (CAs) are one of the effects of radiation exposure and are used as a biomarker. A new simulation program, named RITCARD (Radiation induced tracks, chromosome aberrations, repair, and damage) was developed to simulate radiation-induced CA. RITCARD is used with the program RITRACKS (Relativistic Ion Tracks), which simulates the radiation tracks. The restitution kinetics algorithm presented here is a significant improvement over the one used in the first version. Simulations of radiation-induced CA were performed for several ion types and mixed irradiation fields. These simulations will be useful to help interpreting experiments of galactic cosmic rays (GCR) simulator.

Plante, Ianik

The Badhwar-O'Neill 2020 Model

The Badhwar-O'Neill (BON) model has been used for some time to describe the galactic cosmic ray (GCR) environment encountered in deep space by astronauts and sensitive electronics. The most recent version of the model, BON2014, was calibrated to available measurements to reduce model errors for particles and energies of significance to astronaut exposure. Although subsequent studies showed the model to be reasonably accurate for such applications, modifications to the sunspot number (SSN) classification system and a large number of new high precision measurements suggested the need to develop an improved and more capable model. In this work, the BON2020 model is described. The new model relies on daily integral flux from the Advanced Composition Explorer Cosmic Ray Isotope Spectrometer (ACE/CRIS) to describe solar activity. For time periods not covered by ACE/CRIS, the updated international SSN database is used. Parameters in the new model are calibrated to available data, which includes the new Alpha Magnetic Spectrometer (AMS-02) and Payload for Antimatter Matter Exploration and Light-nuclei Astrophysics (PAMELA) high-precision measurements. It is found that the BON2020 model is a significant improvement over BON2014. Systematic errors associated with BON2014 have been removed. The average relative error of the BON2020 model compared to all available measurements is found to be <1%, and BON2020 is found to be within ±15% of a large fraction of the available measurements (26,269 of 27,646 → 95%).

Slaba, Tony C.

Effects of the Serber First Step in 3DHZETRN-v2.1

3DHZETRN-v2 includes a detailed three dimensional (3D) treatment of neutron/light-ion transport based on a quasi-elastic/multiple-production assumption allowing improved agreement of the neutron/light-ion fluence compared with results of three Monte Carlo (MC) codes in the sense that the variance with respect to the individual MC results is less than the variance among the MC code results. The current numerical methods are no longer the main limitation to HZETRN code development and further changes in the nuclear model are required. In a prior study, an improved quasi-elastic spectrum based on a solution of the transport approximation to nuclear media effects showed promise, but the remaining multiple-production spectrum was based on a database derived from the Ranft model that used Bertini multiplicities. In the present paper, we will implement a more complete Serber first step into the 3DHZETRN-v2 code, but we retain the Bertini-Ranft branching ratios and evaporation multiplicities. It is shown that the new Serber model in the 3HZETRN-v2 code reduces the variance with individual MC codes, which are largely due to nuclear cross section model differences.

Wilson, John W.

Comparison of Space Radiation GCR Models to AMS Heavy Ion Data

Galactic cosmic rays (GCR) are a constant source of radiation that constitutes one of the major hazards during deep space exploration missions for both astronauts and hardware. In this work, GCR models commonly used by the space radiation protection community are compared with recently published high-precision, high- resolution measurements of cosmic ray lithium, beryllium, boron, carbon, nitrogen, and oxygen fluxes along with their ratios (Li/B, Li/C, Li/O, Be/B, Be/C, Be/O, B/C, B/O, C/O, N/B, N/O) from the Alpha Magnetic Spectrometer (AMS). All of the models were developed and calibrated prior to the publication of this AMS data, therefore this is an opportunity to validate the models against an independent data set. This paper is a compliment to the previously published comparison of GCR models with AMS hydrogen, helium, and the boron-to-carbon ratio.

Whitman, Kathryn

3DHZETRN: Inhomogeneous Geometry Issues

Historical methods for assessing radiation exposure inside complicated geometries for space applications were limited by computational constraints and lack of knowledge associated with nuclear processes occurring over a broad range of particles and energies. Various methods were developed and utilized to simplify geometric representations and enable coupling with simplified but efficient particle transport codes. Recent transport code development efforts, leading to 3DHZETRN, now enable such approximate methods to be carefully assessed to determine if past exposure analyses and validation efforts based on those approximate methods need to be revisited. In this work, historical methods of representing inhomogeneous spacecraft geometry for radiation protection analysis are first reviewed. Two inhomogeneous geometry cases, previously studied with 3DHZETRN and Monte Carlo codes, are considered with various levels of geometric approximation. Fluence, dose, and dose equivalent values are computed in all cases and compared. It is found that although these historical geometry approximations can induce large errors in neutron fluences up to 100 MeV, errors on dose and dose equivalent are modest (<10%) for the cases studied here.

Wilson, John W.

Neutron Angular Scatter Effects in 3DHZETRN: Quasi-Elastic

The current 3DHZETRN code has a detailed three dimensional (3D) treatment of neutron transport based on a forward/isotropic assumption and has been compared to Monte Carlo (MC) simulation codes in various geometries. In most cases, it has been found that 3DHZETRN agrees with the MC codes to the extent they agree with each other. However, a recent study of neutron leakage from finite geometries revealed that further improvements to the 3DHZETRN formalism are needed. In the present report, angular scattering corrections to the neutron fluence are provided in an attempt to improve fluence estimates from a uniform sphere. It is found that further developments in the nuclear production models are required to fully evaluate the impact of transport model updates. A model for the quasi-elastic neutron production spectra is therefore developed and implemented into 3DHZETRN.

Wilson, John W.

Solar Proton Transport Within an ICRU Sphere Surrounded by a Complex Shield: Ray-trace Geometry

A computationally efficient 3DHZETRN code with enhanced neutron and light ion (Z is less than or equal to 2) propagation was recently developed for complex, inhomogeneous shield geometry described by combinatorial objects. Comparisons were made between 3DHZETRN results and Monte Carlo (MC) simulations at locations within the combinatorial geometry, and it was shown that 3DHZETRN agrees with the MC codes to the extent they agree with each other. In the present report, the 3DHZETRN code is extended to enable analysis in ray-trace geometry. This latest extension enables the code to be used within current engineering design practices utilizing fully detailed vehicle and habitat geometries. Through convergence testing, it is shown that fidelity in an actual shield geometry can be maintained in the discrete ray-trace description by systematically increasing the number of discrete rays used. It is also shown that this fidelity is carried into transport procedures and resulting exposure quantities without sacrificing computational efficiency.

Slaba, Tony C.

Solar Proton Transport within an ICRU Sphere Surrounded by a Complex Shield: Combinatorial Geometry

The 3DHZETRN code, with improved neutron and light ion (Z (is) less than 2) transport procedures, was recently developed and compared to Monte Carlo (MC) simulations using simplified spherical geometries. It was shown that 3DHZETRN agrees with the MC codes to the extent they agree with each other. In the present report, the 3DHZETRN code is extended to enable analysis in general combinatorial geometry. A more complex shielding structure with internal parts surrounding a tissue sphere is considered and compared against MC simulations. It is shown that even in the more complex geometry, 3DHZETRN agrees well with the MC codes and maintains a high degree of computational efficiency.

Wilson, John W.

Galactic Cosmic Ray Simulator at the NASA Space Radiation Laboratory

The external Galactic Cosmic Ray (GCR) spectrum is significantly modified when it passes through spacecraft shielding and astronauts. One approach for simulating the GCR space radiation environment is to attempt to reproduce the unmodified, external GCR spectrum at a ground based accelerator. A possibly better approach would use the modified, shielded tissue spectrum, to select accelerator beams impinging on biological targets. NASA plans for implementation of a GCR simulator at the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory will be discussed.

Norbury, John W.

November 2013 Analysis of High Energy Electrons on the Japan Experimental Module (JEM: Kibo)

Albedo (precipitating/splash) electrons, created by galactic cosmic rays (GCR) interaction with the upper atmosphere move upwards away from the surface of the earth. In the past validation work these particles were often considered to have negligible contribution to astronaut radiation exposure on the International Space Station (ISS). Estimates of astronaut exposure based on the available Computer Aided Design (CAD) models of ISS consistently underestimated measurements onboard ISS when the contribution of albedo particles to exposure were neglected. Recent measurements of high energy electrons outside ISS Japan Experimental Module (JEM) using Exposed Facility (EF), Space Environment Data Acquisition Equipment - Attached Payload (SEDA-AP) and Standard DOse Monitor (SDOM), indicates the presence of high energy electrons at ISS altitude. In this presentation the status of these energetic electrons is reviewed and mechanism for the creation of these particles inside/outside South Atlantic Anomaly (SAA) region explained. In addition, limited dosimetric evaluation of these electrons at 600 MeV and 10 GeV is presented.

Badavi, Francis F.

International Collaboration for Galactic Cosmic Ray Simulation at the NASA Space Radiation Laboratory

An international collaboration on Galactic Cosmic Ray (GCR) simulation is being formed to make recommendations on how to best simulate the GCR spectrum at ground based accelerators. The external GCR spectrum is significantly modified when it passes through spacecraft shielding and astronauts. One approach for simulating the GCR space radiation environment at ground based accelerators would use the modified spectrum, rather than the external spectrum, in the accelerator beams impinging on biological targets. Two recent workshops have studied such GCR simulation. The first workshop was held at NASA Langley Research Center in October 2014. The second workshop was held at the NASA Space Radiation Investigators' workshop in Galveston, Texas in January 2015. The anticipated outcome of these and other studies may be a report or journal article, written by an international collaboration, making accelerator beam recommendations for GCR simulation. This poster describes the status of GCR simulation at the NASA Space Radiation Laboratory and encourages others to join the collaboration.

Norbury, John W.

Galactic Cosmic Ray Simulation at the NASA Space Radiation Laboratory

The external Galactic Cosmic Ray (GCR) spectrum is significantly modified when it passes through spacecraft shielding and astronauts. One approach for simulating the GCR space radiation environment at ground based accelerators would use the modified spectrum, rather than the external spectrum, in the accelerator beams impinging on biological targets. Two recent workshops have studied such GCR simulation. The first workshop was held at NASA Langley Research Center in October 2014. The second workshop was held at the NASA Space Radiation Investigators' workshop in Galveston, Texas in January 2015. The results of these workshops will be discussed in this paper.

Norbury, John W.