Search NASA⌕ Search

Engineering topics

Smart, John E.

Publications and source records attributed to Smart, John E..

Modular Subsurface Sensors and Integrated Software for Advanced Subsurface Characterization and Monitoring using Unoccupied Vehicles

The advent and subsequent proliferation of autonomous airborne, waterborne, and groundbased vehicles (i.e., “drones”) promises to broadly transform the geosciences and associated industries, including fossil energy exploration and development, mineral resource exploration and development, water-resource management, and environmental remediation. For geophysical characterization and monitoring, the prospect of programming highly repeatable and low-cost drone missions for subsurface imaging will allow for deployments in hazardous and previously inaccessible areas. Coupled with autonomous workflows for data processing, management, and visualization, drone-based geophysical characterization and monitoring will enable unprecedented, real-time insight into diverse subsurface properties and processes of scientific and engineering importance. Toward this end, the objectives of this Lab Directed Research and Development (LDRD) project were to develop new (1) instrumentation for dronebased electromagnetic induction (EMI) geophysical imaging, including separated transmitter and receivers and associated electronics, (2) software for real-time data telemetry, processing, management, and visualization. Although EMI has been previously deployed using unoccupied aerial systems (UASs), these applications failed to capitalize on the game-changing capabilities of drone platforms. Whereas drone-based data acquisition allows for collection of rich, three-dimensional (3D) multi-offset/multi-angle configurations between transmitters and receivers, past efforts have relied on conventional instrumentation that was designed for ground-based data collection with the transmitter and a single receiver housed in the same unit; nor did these previous applications demonstrate real-time delivery of results to support rapid management decisions in the field. In this 1-year project, we (1) designed and constructed new lightweight independent transmitter and receiver antenna platforms that communicate with a laptop computer; (2) developed software to control data acquisition, manage/transfer data, and visualize data as its collected; and (3) demonstrated the operation of the new hardware and software systems in a ground-based field test. Our work entails major technological advances for EMI and established a foundation on which to build a new drone-based, real-time geophysical EMI imaging capability to support diverse challenges facing the nation.

47 OTHER INSTRUMENTATION↗

Future of Radionuclide Aerosol Monitoring Systems

In the 1990s, Pacific Northwest National Laboratory staff developed the Radionuclide Aerosol Sampler Analyzer (RASA) for worldwide aerosol monitoring. RASA won an R&D 100 award in 1998 and a Federal Laboratory Consortium tech transfer award in 2000. For the last several years, staff of PNNL and Creare have made investigations into aspects of upgrading the RASA. Key themes have been a modular approach to additional radionuclide measurements, optimizing the sampling/analyzing times to improve detection and location capability, and improving the power consumption via the use of electrostatic collection versus classic filtration. These individual efforts have been made in the context of retrofits to the existing RASA. In in this work, we consider a complete RASA redesign at a notional level. Individual studies reported here contain theory and experimental investigations, but none of these has been tested with the others, and further work is needed to verify these gains. With these caveats, this work shows that substantial optimization of detection and location capability of a network of RASA systems is possible, multiple mission spaces can be addressed with additional measurements, and electrostatic collection is a practical advantage, although more work is needed. The quite unexpected result of this study is that some optimization of the existing RASA is possible without any hardware changes at all.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Investigations of degradation and encapsulation of plastic scintillator

Studies have revealed that plastic scintillators such as polyvinyl toluene and polystyrene can undergo environmentally related material damage (“fogging”) that adversely affects detection performance under certain conditions and histories. A significant decrease in sensitivity has been seen in some gamma-ray detectors as they age as a result of this damage. Performance degradation due to such damage is characterized by a signal change from the detector, which shifts to lower energy, and ultimately a reduction in the ability to detect gamma radiation. This degradation is due to the permeation of water into the plastic, which can then cause temporary fogging and permanent damage to the material. As an example, a 1-mm thick barrier of high-density polyethylene with an area of 1 m 2 would allow 5 g per year of water transmission at 100% relative humidity. Thus, significant amounts of water can penetrate plastics over time and provide the potential for damage to the plastic. Such damage to plastic scintillator can cause problems for radiation detection applications in uncontrolled environments. Mitigation approaches that have been proposed to prevent damage to plastic scintillator include encapsulation of the plastic scintillator to prevent water intrusion that leads to damage during cold cycles. It is concluded that an encapsulation material with a moisture vapor transmission rate on the order of 10 -4 g∙m -2 ∙d -1 or better is needed for protecting large pieces of plastic scintillator from fogging over years of use. This article presents information on testing of bare and encapsulated plastic scintillator samples and on diagnostic approaches to measure the nature and progression of the fogging condition. It is shown that several encapsulation approaches fail to prevent water intrusion, while a couple methods can successfully encapsulate plastic and prevent water from penetrating the plastic and producing fogging.

36 MATERIALS SCIENCE↗

A wearable sensor based on CLYC scintillators

We developed a wearable radiation sensor using Cs 2 LiYCl 6 :Ce (CLYC) for simultaneous gamma-ray and neutron detection. The system includes two ø2.5×2.5 cm 3 crystals coupled to small, metal-body photomultiplier tubes. A custom, low-power electronics base digitizes the output signal at three time points and enables both pulse height and pulse shape discrimination of neutrons and gamma-rays. Data, including spectra, can be transferred via a wired or wireless connection. The total gamma-ray and neutron counts, anomaly detection metrics, and identified isotopes are displayed on a small screen on the device. Users may leave the system in unattended mode to collect long-dwell energy spectra. The prototype system has overall dimensions of 13×7.5×18 cm 3 and weight of 1.3 kg, not including the protective pouch, and runs on six AA alkaline batteries for 29 hours with a 1% wireless transmission duty cycle and 41 hours with the wireless turned off . In this paper, we summarize the system design and present characterization results from the detector modules. The energy resolution is about 6.5% full width at half maximum at 662 keV due to the small photomultiplier tube selected, and the linearity and pulse shape discrimination performance are very good.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Unattended Sensor System With CLYC Detectors

We have developed a next-generation unattended sensor for detecting anomalous radiation sources. The system combines several technologies to reduce size and weight, increase battery lifetime, and improve decision-making capabilities. Sixteen Cs2LiYCl6:Ce (CLYC) scintillators allow for gamma-ray spectroscopy and neutron detection in the same volume. Low-power electronics for readout, high voltage bias, and digital processing reduce the total operating power to 1.3 W. Computationally efficient analysis algorithms perform spectral anomaly detection and isotope identification. When an alarm occurs, the system transmits alarm information over a cellular modem. In this paper, we describe the overall design of the unattended sensor, present characterization results, and compare the performance to stock NaI:Tl and 3He detectors.

CLYC↗

Nuclear Safeguards Applications Employing Unmanned Airborne Vehicles

This paper describes some potential applications for UAVs (Unmanned Aerial Vehicles) in international nuclear safeguards. UAV missions can include indoor and outdoor operations including: 1) surveillance, which includes all types of sensors and imagers, 2) command and control augmentation (radio relays and real-time imagery used primarily to coordinate ground operations), and 3) physical sample collection and transport.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Using Atmospheric Dispersion Theory to Inform the Design of a Short-lived Radioactive Particle Release Experiment

Atmospheric dispersion theory can be used to predict ground deposition of particulates downwind of a radionuclide release. This paper utilizes standard formulations found in Gaussian plume models to inform the design of an experimental release of short-lived radioactive particles into the atmosphere. Specifically, a source depletion algorithm is used to determine the optimum particle size and release height that maximizes the near-field deposition while minimizing the both the required source activity and the fraction of activity lost to long-distance transport. The purpose of the release is to provide a realistic deposition pattern that might be observed downwind of a small-scale vent from an underground nuclear explosion. The deposition field will be used, in part, to investigate several techniques of gamma radiation survey and spectrometry that could be utilized by an On-Site Inspection team under the verification regime of the Comprehensive Nuclear-Test-Ban Treaty.

Atmospheric dispersion↗

PRex: An Experiment to Investigate Detection of Near-field Particulate Deposition from a Simulated Underground Nuclear Weapons Test Vent

An experiment to release radioactive particles representative of small-scale venting from an underground nuclear test was conducted to gather data in support of treaty capability development activities. For this experiment, a CO2-driven “air cannon” was used to release lanthanum-140 at ambient temperatures. The radioisotope 140La was chosen as a representative fission fragment with a short half-life and prominent gamma-ray emissions; the choice was also influenced by the successful production and use of 140La with low levels of radioactive contaminants in the Defence Research and Development Canada Field Trials. The source was created through activation of high-purity lanthanum oxide at the TRIGA research reactor of Washington State University, Pullman, Washington. Witness plates and air samplers were laid out in an irregular grid covering the area for which the plume was anticipated to deposit based on climatological wind records. A vehicle-mounted spectrometer, and handheld and backpack instruments ranging from polyvinyl toluene to high purity germanium, were used to survey the plume. Additionally, three soil sampling techniques were investigated. The relative sensitivity and utility of sampling and survey methods are discussed in the context of On-Site Inspection.

atmospheric dispersion↗

Design of the Laboratory-Scale Plutonium Oxide Processing Unit in the Radiochemical Processing Laboratory

This report describes a design for a laboratory-scale capability to produce plutonium oxide (PuO 2 ) for use in identifying and validating nuclear forensics signatures associated with plutonium production, as well as for use as exercise and reference materials. This capability will be located in the Radiochemical Processing Laboratory at the Pacific Northwest National Laboratory. The key unit operations are described, including PuO 2 dissolution, purification of the Pu by ion exchange, precipitation, and re-conversion to PuO 2 by calcination.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Particle Release Experiment (PRex) (Final Report)

An experiment to release radioactive particles representative of small-scale venting from an underground nuclear test was conducted to gather data in support of treaty verification and monitoring activities. For this experiment, a CO 2 -driven “air cannon” was used to release La-140 at ambient temperatures. Lanthanum-140 was chosen to represent the fission fragments because of its short half-life and prominent gamma-ray emissions; the choice was also influenced by the successful production and use of La-140 with low levels of radioactive contaminants in a Defence Research and Development Canada Field Trial. The source was created through activation of high-purity natural lanthanum oxide at the reactor of Washington State University, Pullman, Washington. Multiple varieties of witness plates and air samplers were laid in an irregular grid covering the area over which the plume was modeled to deposit. Aerial survey, a NaI(Tl) mobile spectrometer, and handheld and backpack instruments ranging from polyvinyl toluene to high-purity germanium were used to survey the plume. Additionally, three varieties of soil sampling were investigated. The relative sensitivity and utility of sampling and survey methods are discussed in the context of On-Site Inspection. The measurements and samples show a high degree of correlation and form a valuable set of test data.

54 ENVIRONMENTAL SCIENCES↗

System Modeling and Design Optimization for a Next-Generation Unattended Sensor

We are developing a next-generation unattendedsensor that can detect and identify radiation sources while operating on battery power for several weeks. The system achieves smaller size and weight over systems that use NaI:Tl and 3He detectors by using a relatively new scintillator, Cs2LiYCl6:Ce:Ce (CLYC). This material can detect both gamma rays and thermal neutrons, has energy resolution of ~4% full width at half maximum at 662 keV, and allows for particle discrimination by pulse amplitude as well as pulse shape. The overall design features an array of sixteen CLYC detectors, each read out by a photomultiplier tube and custom pulse processing electronics. A field-programmable gate array analyzes the energy spectra using computationally efficient algorithms for anomaly detection.

McDonald, Benjamin S.↗