Search NASA⌕ Search

Engineering topics

Smith, Brennan T.

Publications and source records attributed to Smith, Brennan T..

At least 19 records

Coupled Heat Power Operation of Smart Buildings via Modular Pumped Hydro Storage

In the United States, building sector is responsible for around 40% of total energy consumption and contributes about 40% of carbon emissions since 2012. Within the past several years, various optimization models and control strategies have been studied to improve buildings’ energy efficiency and reduce operational expenses under the constraints of satisfying occupants’ comfort requirements. However, the majority of these studies consider building electricity demand and thermal load being satisfied by unidirectional electricity flow from the power grid or on-site renewable energy generation to electrical and thermal home appliances. Opportunities for leveraging low-grade heat for electricity have largely been overlooked due to impracticality at small scale. In 2016, a modular pumped hydro storage technology was invented in Oak Ridge National Laboratory, named Ground Level Integrated Diverse Energy Storage (GLIDES). In GLIDES, employing high-efficiency hydraulic machinery instead of gas compressor/turbine, liquid is pumped to compress gas inside high-pressure vessel creating head on ground level. This unique design eliminates the geographical limitation associated with the existing state-of-the-art energy storage technologies. It is easy to be scaled for building level, community level, and grid level applications. By using this novel hydro-pneumatic storage technology, opportunities for leveraging low-grade heat in building can be economical. In this research, the potential of utilizing low-grade thermal energy to augment electricity generation of GLIDES is investigated. Since GLIDES relies on gas expansion in the discharge process and the gas temperature drops during this non-isothermal process, available thermal energy, e.g., from thermal storage, combined cooling, heat and power system (CCHP), can be utilized by GLIDES to counter the cooling effect of the expansion process and elevate the gas temperature and pressure and boost the roundtrip efficiency. Here, several groups of comparison experiments have been conducted, and the experimental results show that a maximum 12.9% cost saving could be achieved with unlimited heat source for GLIDES, and a moderate 3.8% cost improvement can be expected when operated coordinately with CCHP and thermal energy storage in a smart building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Developing a digital twin for hydropower systems - an open platform framework

The definition of digital twin in Wikipedia says “A digital twin is a virtual representation that serves as the real-time digital counterpart of a physical object or process.” Indeed, the digital twin (DT) concept was initially introduced at the start of the 21st century with intent to create a digital model to reflect physical systems and derive insight from the model to make the decision on system operation. DT is also a promising enabling technology for realising smart manufacturing and industry 4.0. In general, DTs consist of three main parts: physical product, virtual product, and connected data that link physical and virtual product via various data communication schemes.

13 HYDRO ENERGY↗

Heat Based Power Augmentation for Modular Pumped Hydro Storage in Smart Buildings Operation

In the U.S., building sector is responsible for around 40% of total energy consumption and contributes about 40% of carbon emissions since 2012. Within the past several years, various optimization models and control strategies have been studied to improve buildings energy efficiency and reduce operational expenses under the constraints of satisfying occupants’ comfort requirements. However, the majority of these studies consider building electricity demand and thermal load being satisfied by unidirectional electricity flow from the power grid or on-site renewable energy generation to electrical and thermal home appliances. Opportunities for leveraging low grade heat for electricity have largely been overlooked due to impracticality at small scale. In 2016, a modular pumped hydro storage technology was invented in Oak Ridge National Laboratory, named Ground Level Integrated Diverse Energy Storage (GLIDES). In GLIDES, employing high efficiency hydraulic machinery instead of gas compressor/turbine, liquid is pumped to compress gas inside high-pressure vessel creating head on ground-level. This unique design eliminates the geographical limitation associated with existing state of the art energy storage technologies. It is easy to be scaled for building level, community level and grid level applications. Using this novel hydro-pneumatic storage technology, opportunities for leveraging low-grade heat in building can be economical. In this research, the potential of utilizing low-grade thermal energy to augment electricity generation of GLIDES is investigated. Since GLIDES relies on gas expansion in the discharge process and the gas temperature drops during this non-isothermal process, available thermal energy, e.g. from thermal storage, Combined Cooling, Heat and Power system (CCHP), can be utilized by GLIDES to counter the cooling effect of the expansion process and elevate the gas temperature and pressure and boost the roundtrip efficiency. Several groups of comparison experiments have been conducted and the experimental results show that a maximum 12.9% cost saving could be achieved with unlimited heat source for GLIDES, and a moderate 3.8% cost improvement can be expected when operated coordinately with CCHP and thermal energy storage in a smart building.

Chen, Yang↗

BI-LEVEL OPTIMIZATION FOR ELECTRICITY TRANSACTION IN SMART COMMUNITY WITH MODULAR PUMP HYDRO STORAGE

Grid integration of the increasing distributed energy resources could be challenging in terms of new infrastructure investment, power grid stability, etc. To resolve more renewables locally and reduce the need for extensive electricity transmission, a community energy transaction market is assumed with market operator as the leader whose responsibility is to generate local energy prices and clear the energy transaction payment among the prosumers (followers). The leader and multi-followers have competitive objectives of revenue maximization and operational cost minimization. This non-cooperative leader-follower (Stackelberg) game is formulated using a bi-level optimization framework, where a novel modular pump hydro storage technology (GLIDES system) is set as an upper level market operator, and the lower level prosumers are nearby commercial buildings. The best responses of the lower level model could be derived by necessary optimality conditions, and thus the bi-level model could be transformed into single level optimization model via replacing the lower level model by its Karush-Kuhn-Tucker (KKT) necessary conditions. Several experiments have been designed to compare the local energy transaction behavior and profit distribution with the different demand response levels and different local price structures. The experimental results indicate that the lower level prosumers could benefit the most when local buying and selling prices are equal, while maximum revenue potential for the upper level agent could be reached with non-equal trading prices.

Chen, Yang↗

Pumped Storage Hydropower (PSH) FAST Commissioning Prize Technical Analysis

The US energy landscape has undergone major changes over the past 10 years and will continue to see significant changes in future decades as the power grid increases its reliance on variable renewable energy resources. Because of the inherent variability of these resources, renewable energy growth may require additional energy storage capacity to provide flexible load-following capabilities and other grid services that can quickly adjust to changes in energy demand and generation. Pumped storage hydropower (PSH)—one such energy storage technology—uses pumps to convey water from a lower reservoir to an upper reservoir for energy storage and releases water back to the lower reservoir via a powerhouse for hydropower generation. PSH facility pump and generation cycling often follows economic and energy demand conditions. Across the United States, 43 PSH facilities are in operation and 55 projects are in various permitting or licensing stages. Altogether, the 43 operational projects provide the wide majority (95%) of utility-scale electricity storage in the United States. These facilities also provide significant power and nonpower grid benefits, including large-scale electrical system reserve capacity, grid reliability support, and electricity supply-demand balancing through quick-response capabilities and operational flexibility. PSH systems can accomplish these at a scale (e.g., size) and cost that makes these systems highly attractive from a technical standpoint. Although these research concepts are still in their infancy, they demonstrate promising potential as future PSH energy storage technologies. Although PSH has many advantages, development in the United States has effectively stalled since the 1990s, partially because of the magnitude of project costs and financing interest during development and construction, the length of time from project investment until project revenue begins, permitting challenges, construction risks, competition from other storage technologies (e.g., batteries, hydrogen storage), and electricity market evolution and uncertainty. In short, the time, cost, and risk associated with modern PSH development have resulted in limited growth in the United States recently, despite the growing energy storage demand stemming from increased wind and solar power deployment. Technology innovation is needed to help reduce PSH commissioning time, cost, and risk, particularly during the post-licensing phase of project development. To address challenges facing the PSH industry and to improve PSH commissioning timelines, the US Department of Energy (DOE) Water Power Technologies Office (WPTO) initiated the PSH Furthering Advancements to Shorten Time to (FAST) Commissioning Prize project.

13 HYDRO ENERGY↗

Allocation and Operation of A Hydropneumatic Energy Storage with Building Microgrid

Behind-meter application for a recently invented hydropneumatic Ground-Level Integrated Diverse Energy Storage (GLIDES) is focused in this research. Considering possible uncertainties from solar radiation and electricity load in a building microgrid, two-stage stochastic programming is adopted for 15-min operation and a mixed-integer nonlinear stochastic model is built with integrated energy systems of GLIDES, solar panel and power generating unit. In order to make the model computationally tractable, we use sample average approximate method to decrease associated complexity with sample size and improve solving efficiency. The experimental results in deterministic and stochastic operation indicate that best candidate solution from SAA are superior to the solution from expected value problem in terms of optimality gap and variance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PART 1- techno-economic analysis of a grid scale Ground-Level Integrated Diverse Energy Storage (GLIDES) technology

In this paper, a techno-economic model / cost reduction analysis of a low-cost, dispatchable / scalable, efficient Ground-Level Integrated Diverse Energy Storage (GLIDES) system is analyzed, along with a review of existing state-of-the-art energy storage technologies. The introduced technology, GLIDES, which was invented at the Oak Ridge National Laboratory (ORNL), stores energy by compression and expansion of air using water as a liquid piston inside high-pressure reservoirs. GLIDES is introduced by combining Pumped Hydroelectric Storage (PHS) and Compressed Air Energy Storage (CAES) technologies. Here, by replacing inefficient gas compressor and turbine with higher efficiency liquid turbomachines for liquid-piston compression/expansion, GLIDES achieves higher roundtrip efficiency than other gas compression-based energy storage technologies and is a scalable energy storage system. For cost reduction purposes, various pressure reservoirs including steel vessels, carbon fiber vessels, pipe segments, and underground pressure reservoirs are analyzed in this paper. Based on the analyzed data using the models discussed in this paper, energy storage costs as low as ~$14/kWh and ~346/kWh (roundtrip efficiency (RTE) ~80%) can be achieved for a grid-scale GLIDES using depleted oil/gas reservoirs and high-pressure pipe segments respectively.

25 ENERGY STORAGE↗

Surrogate Modeling for Capacity Planning of Charging Station Equipped with PV and Hydropneumatic Energy Storage

Due to the promising potential for environmental sustainability, there has been a significant increase of electric vehicles (EVs) and plug-in hybrid electric vehicles (PHEV) in the market. To support this increasing demand for EVs and PHEVs, challenges related to capacity planning and investment costs of public charging infrastructure must be addressed. Hence, in this paper, a capacity planning problem for EV charging stations is developed and aims to balance current capital investment costs and future operational revenue. The charging station considered in this work is assumed to be equipped with solar photovoltaic panel (PV) and an energy storage system which could be electric battery or the recently invented hydro-pneumatic energy storage (GLIDES, Ground-Level Integrated Diverse Energy Storage) system. A co-optimization model that minimizes investment and operation cost is established to determine the global optimal solution while combining the capacity and operational decision making. The operational decision making considers EV mobility which is modeled as an Erlang-loss system. Meanwhile, stochastic programming is adopted to capture uncertainties from solar radiation and charging demand of the EV fleet. To provide a more general and computationally efficient model, main configuration parameters are sampled in the design space and then fixed in solving the co-optimization model. The model can be used to provide insights for charging station placement in different practical situations. The sampled parameters include: the total number of EV charging slots, the PV area, the maximum capacity of the energy storage system, and daily mean EV arrival number in the Erlang-loss system. Based on the sampled parameter combinations and its responses, black-box mappings are then constructed using surrogate models (RBF, Kriging etc). The effectiveness of proposed surrogate modeling approach is demonstrated in the numerical experiments.

Chen, Yang↗

A Checklist of River Function Indicators for hydropower ecological assessment

Hydropower generation has benefits for societies that seek low-carbon, renewable energy alternatives, but sustainable hydropower production will require an explicit consideration of potential tradeoffs between socioeconomic and environmental priorities. These tradeoffs are typically explored during a formal environmental impact assessment process that can be complex and controversial. The steps taken to address stakeholder concerns through impact hypotheses and field studies are not always transparent. We have designed a Checklist of River Function Indicators to facilitate stakeholder discussions during hydropower licensing and to support more transparent, holistic, and scientifically informed hydropower environmental analyses. Based on a database of environmental metrics collected from hydropower project studies documented by the Federal Energy Regulatory Commission (FERC), the International Hydropower Association, the Low Impact Hydropower Institute, and peer-reviewed scientific literature, our proposed Checklist of River Function Indicators contains 51 indicators in six categories. We have tested the usefulness of the Indicators by applying them to seven hydropower projects documented by FERC. Among the case study projects, 44 of the 51 Indicators were assessed according to the FERC documentation. Although each hydropower project presents unique natural resource issues and stakeholder priorities, the proposed Indicators can provide a transparent starting point for stakeholder discussions about which ecological impacts should be considered in hydropower planning and relicensing assessments.

13 HYDRO ENERGY↗

Preliminary analysis of market potential for a hydropneumatic ground-level integrated diverse energy storage system

With the increasing share of renewable energy in the power grid, energy storage is considered a viable and effective solution to mitigate intermittency and improve power system stability. To quantify and estimate market potential for a recently developed Ground-Level Integrated Diverse Energy Storage (GLIDES) technology, the first operation model is developed for this hydropneumatic system and the bilinear pressure-volume terms are then linearized using the binary McCormick Relaxation method to improve solving efficiency. Based on up-to-date 5-min price data in four different real-time markets, several sets of experiments have been designed with three objective scenarios: maximize arbitrage, maximize arbitrage + reserve, maximize arbitrage + reserve + regulation. The experimental results show that the monetary value of GLIDES could be boosted by participation in ancillary markets and that regulation service might contribute more than half of the total revenue, even as high as 90% in PJM and ISONE markets. In addition, a case study for 1-day operation is used to illustrate the volume control of the GLIDES system.

25 ENERGY STORAGE↗

Instruction Manual: River Function Questionnaire

The River Function Questionnaire (Questionnaire) is a series of questions designed to help stakeholders determine the impacts of hydropower on a series of environmental indicators, i.e. river functions, that may need to be understood or addressed through additional field studies or environmental assessments. In order to provide a platform accessible to many users, the questionnaire was developed in Microsoft Excel with convenient macro-enabled interactive features. The Questionnaire was developed under the Department of Energy (DOE)-funded Environmental Metrics for Hydropower (EMH) project in FY 2018. This document provides an instruction manual that provides overall guidance and step-by-step instructions for use.

13 HYDRO ENERGY↗

HydroSource Data Dictionary

In recent years, Oak Ridge National Laboratory (ORNL) has conducted innovative hydropower research sponsored by the US Department of Energy Water Power Technologies Office (WPTO) to address important questions regarding technology advancement, existing hydropower assets, future hydropower potential, environmental concerns, policy and regulatory decisions, and market trends to support hydropower sustainability in the United States. Data from this research supports a broad and diverse user base including US federal, state, and local governments; national laboratories; hydropower industry; academia; nonprofit organizations; and other end users. The development of a relational database system is needed to ensure proper management of the continuously increasing breadth and depth of these data to guarantee their future value and reliability for advancing hydropower research and supporting the goals and objectives of our partners and US hydropower stakeholders. During FY 2018, ORNL’s HydroSource team reconciled data from ORNL’s WPTO-funded projects to create the HydroSource Data Model, Version 1 (HSDM1) schema. The HSDM1 schema provides the essential step in data assimilation toward unifying ORNL’s WPTO-funded data into a relational database management system. This report provides technical documentation of the HSDM1 schema to help guide future development and implementation of the HydroSource database system.

13 HYDRO ENERGY↗

Review of environmental metrics used across multiple sectors and geographies to evaluate the effects of hydropower development

In this paper, as U.S. hydropower development continues to expand, a thorough inventory of potentially relevant environmental metrics will provide a comprehensive and transparent starting point for stakeholders seeking to evaluate the sustainability and environmental effects of this anticipated expansion. To address this need, we conducted a literature review to extract and analyze a swath of environmental metrics related to previous hydropower projects. Our examination of several U.S. Federal Energy Regulatory Commission licensing documents, several certification documents prepared by the Low Impact Hydropower Institute and the International Hydropower Association, and a set of peer-reviewed journal articles led to creation of a database of > 3000 current environmental metrics related to hydropower projects in 231 locations worldwide. Information recorded for each environmental metric was used to map the comprehensiveness and consistency of environmental measurements gathered across primary categories, dam life cycle stages, spatial scales and locations. We found that a majority of environmental metrics were related to water quantity and water quality, a large number of metrics were related to biota and biodiversity, and relatively few metrics were related to the categories of geomorphology, land cover, connectivity and fragmentation, and infrastructure and design. However, the categories of environmental metrics represented in each type of literature varied significantly. Forty-five subcategories of environmental metrics emerged from our analysis, thereby suggesting a potential envelope of environmental measurements that might be used to improve efficiency in evaluating the potential environmental effects of new U.S. hydropower projects.

13 HYDRO ENERGY↗

Surrogate Modeling for Capacity Planning of Charging Station Equipped With Photovoltaic Panel and Hydropneumatic Energy Storage

Due to the promising potential for environmental sustainability, there has been a significant increase of electric vehicles (EVs) and plug-in hybrid electric vehicles (PHEV) in the market. To support this increasing demand for EVs and PHEVs, challenges related to capacity planning and investment costs of public charging infrastructure must be addressed. Hence, in this paper, a capacity planning problem for charging stations is developed and aims to balance the current capital investment costs and future operational revenue. The charging station is assumed to be equipped with the solar photovoltaic (PV) panel and an energy storage system, which could be electric battery or recently invented hydropneumatic energy storage (ground-level integrated diverse energy storage (GLIDES)) system. A co-optimization model that minimizes investment and operation cost is established to determine optimal solution while considering capacity planning and following operations. EV mobility is modeled as an Erlang-loss system. Meanwhile, stochastic programming is adopted to capture uncertainties from solar radiation and charging demand of EV fleet. To provide a more general and computationally efficient model, main configuration parameters are sampled in design space and then fixed in solving the co-optimization model. Sampled parameters include EV charging slots number, PV area, capacity of energy storage system, and daily mean EV arrival number. Based on the sampled parameter combinations and its responses, black-box mappings are then constructed using surrogate models, which could provide insights for charging station placement in different practical situations. The effectiveness of the proposed surrogate modeling approach is demonstrated in numerical experiments. Here, the results indicate better profit advantage of GLIDES over battery system with the increased power capacity

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reliability Indexing of Intra-Facility Dispatch Decisions

The Powertrain Reliability Index (PRI) quantifies the trade-offs made in system reliability for efficiency, water use, and environmental purposes for relevant stakeholders. Using historical data from five North American hydroelectric facilities on a shared river system, this metric characterizes the annual probabilistic reliability of intra-facility dispatch decisions. The metric characterizes the operational risk of actual dispatch based on the lowest risk-exposed dispatch and the highest risk-exposed dispatch. By normalizing facility reliability by the number of components described within the facility, constraining operation by the historic dispatch total of unit starts and generating hours, and bounding by required grid flexibility, each facility’s dispatch can be scored for reliability.

Signore, Stephen R.↗

Burden on hydropower units for short-term balancing of renewable power systems

There is a general need to change hydropower operational regimes to balance the growing contribution of variable renewable energy sources in power systems. Quantifying the burden on generation equipment is increasingly uncertain and difficult. Here, we propose a framework combining technical and economic indicators to analyze primary frequency control (PFC) on a timescale of seconds. We develop a model integrating hydraulic, mechanical, and electrical subsystems to characterize efficiency loss, wear and fatigue, regulation mileage, and frequency quality. We evaluate burden relief strategies under three idealized remuneration schemes for PFC, inspired by those used in Sweden, the USA, and China, respectively. We show how burden and compensation vary under future scenarios of renewable power systems. Here, our framework can be used by producers to develop favorable operation strategies that reduce burden and increase economic value, and by transmission system operators to provide insights on the relation between incentive structures and regulating performance.

13 HYDRO ENERGY↗

2018 IEEE International Conference on Probabilistic Methods Applied to Power Systems (PMAPS)

As hydroelectric utilities move toward probabilistic risk assessments that capture the increased degradation resulting from an increase in unit starts, there is a need to capture how reliably a hydroelectric facility is being operated. Traditional statistics like EAF and EFOR are still necessary but do not capture intra-facility decisions made on a yearly or sub-yearly time frame, as it is possible to operate in the least reliable dispatch case for small periods of time and still avoid major unit outages. Our proposed Reliability Index fills this need and provides asset management decision makers with another tool for benchmarking facilities.