Search NASA⌕ Search

Engineering topics

Smith, Emily F.

Publications and source records attributed to Smith, Emily F..

Versailles Project on Advanced Materials and Standards interlaboratory study on intensity calibration for x-ray photoelectron spectroscopy instruments using low-density polyethylene

We report the results of a Versailles Project on Advanced Materials and Standards interlaboratory study on the intensity scale calibration of x-ray photoelectron spectrometers using low-density polyethylene (LDPE) as an alternative material to gold, silver, and copper. An improved set of LDPE reference spectra, corrected for different instrument geometries using a quartz-monochromated Al Kα x-ray source, was developed using data provided by participants in this study. Using these new reference spectra, a transmission function was calculated for each dataset that participants provided. When compared to a similar calibration procedure using the NPL reference spectra for gold, the LDPE intensity calibration method achieves an absolute offset of ~3.0% and a systematic deviation of ±6.5% on average across all participants. For spectra recorded at high pass energies (≥90 eV), values of absolute offset and systematic deviation are ~5.8% and ±5.7%, respectively, whereas for spectra collected at lower pass energies (<90 eV), values of absolute offset and systematic deviation are ~4.9% and ±8.8%, respectively; low pass energy spectra perform worse than the global average, in terms of systematic deviations, due to diminished count rates and signal-to-noise ratio. Differences in absolute offset are attributed to the surface roughness of the LDPE induced by sample preparation. We further assess the usability of LDPE as a secondary reference material and comment on its performance in the presence of issues such as variable dark noise, x-ray warm up times, inaccuracy at low count rates, and underlying spectrometer problems. In response to participant feedback and the results of the study, we provide an updated LDPE intensity calibration protocol to address the issues highlighted in the interlaboratory study. Finally, we also comment on the lack of implementation of a consistent and traceable intensity calibration method across the community of x-ray photoelectron spectroscopy (XPS) users and, therefore, propose a route to achieving this with the assistance of instrument manufacturers, metrology laboratories, and experts leading to an international standard for XPS intensity scale calibration.

36 MATERIALS SCIENCE↗

Experimental Preservation of Muscle Tissue in Quartz Sand and Kaolinite

Siliciclastic sediments of the Ediacaran Period contain exceptionally preserved fossils of macroscopic organisms, including three-dimensional casts and molds commonly found in sandstones and siltstones and some two-dimensional compressions reported in shales. The sporadic and variable associations of these exceptionally preserved macroscopic fossils with pyrite, clay minerals, and microbial fossils and textures complicate our understanding of fossilization processes. This hinders inferences about the evolutionary histories, tissue types, original morphologies, and lifestyles of the enigmatic Ediacara biota. In this work, we investigate the delayed decay of scallop muscles buried in quartz sand or kaolinite for 45 days. This process occurs in the presence of microbial activity in mixed redox environments, but in the absence of thick, sealing microbial mats. Furthermore, microbial processes that mediate organic decay and release the highest concentrations of silica and Fe(II) into the pore fluids are associated with the most extensive tissue decay. Delayed decay and the preservation of thick muscles in sand are associated with less intense microbial iron reduction and the precipitation of iron oxides and iron sulfides that contain Fe(II) or Fe(III). In contrast, muscles buried in kaolinite are coated only by <10 μm-thick clay veneers composed of kaolinite grains and newly formed K- and Fe(II)-rich aluminosilicate phases. Muscles that undergo delayed decay in kaolinite lose more mass relative to the muscles buried in sand and undergo vertical collapse. These findings show that the composition of minerals that coat or precipitate within the tissues and the vertical dimension of the preserved features can depend on the type of sediment that buries the muscles. Similar processes in the zone of oscillating redox likely facilitated the formation of exceptionally preserved macrofossils in Ediacaran siliciclastic sediments.

58 GEOSCIENCES↗

Versailles Project on Advanced Materials and Standards Interlaboratory Study on Measuring the Thickness and Chemistry of Nanoparticle Coatings Using XPS and LEIS

We report the results of a VAMAS (Versailles Project on Advanced Materials and Standards) inter-laboratory study on the measurement of the shell thickness and chemistry of nanoparticle coatings. Peptide-coated gold particles were supplied to laboratories in two forms: a colloidal suspension in pure water and; particles dried onto a silicon wafer. Participants prepared and analyzed these samples using either X-ray photoelectron spectroscopy (XPS) or low energy ion scattering (LEIS). Careful data analysis revealed some significant sources of discrepancy, particularly for XPS. Degradation during transportation, storage or sample preparation resulted in a variability in thickness of 53%. The calculation method chosen by XPS participants contributed a variability of 67%. However, variability of 12% was achieved for the samples deposited using a single method and by choosing photoelectron peaks that were not adversely affected by instrumental transmission effects. The study identified a need for more consistency in instrumental transmission functions and relative sensitivity factors, since this contributed a variability of 33%. The results from the LEIS participants were more consistent, with variability of less than 10 % in thickness and this is mostly due to a common method of data analysis. The calculation was performed using a model developed for uniform, flat films and some participants employed a correction factor to account for the sample geometry, which appears warranted based upon a simulation of LEIS data from one of the participants and comparison to the XPS results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗