Water Tank with Capillary Air/Liquid Separation

A bladderless water tank (see figure) has been developed that contains capillary devices that allow it to be filled and emptied, as needed, in microgravity. When filled with water, the tank shields human occupants of a spacecraft against cosmic radiation. A membrane that is permeable by air but is hydrophobic (neither wettable nor permeable by liquid water) covers one inside surface of the tank. Grooves between the surface and the membrane allow air to flow through vent holes in the surface as the tank is filled or drained. A margin of wettable surface surrounds the edges of the membrane, and all the other inside tank surfaces are also wettable. A fill/drain port is located in one corner of the tank and is covered with a hydrophilic membrane. As filling begins, water runs from the hydrophilic membrane into the corner fillets of the tank walls. Continued filling in the absence of gravity will result in a single contiguous air bubble that will be vented through the hydrophobic membrane. The bubble will be reduced in size until it becomes spherical and smaller than the tank thickness. Draining the tank reverses the process. Air is introduced through the hydrophobic membrane, and liquid continuity is maintained with the fill/drain port through the corner fillets. Even after the tank is emptied, as long as the suction pressure on the hydrophilic membrane does not exceed its bubble point, no air will be drawn into the liquid line.

Ungar, Eugene K.↗

Further Testing of an Amine-based Pressure-Swing System for Carbon Dioxide and Humidity Control

In a crewed spacecraft environment, atmospheric carbon dioxide (CO2) and moisture control are crucial. Hamilton Sundstrand has developed a stable and efficient amine-based CO2 and water vapor sorbent, SA9T, that is well suited for use in a spacecraft environment. The sorbent is efficiently packaged in pressure-swing regenerable beds that are thermally linked to improve removal efficiency and minimize vehicle thermal loads. Flows are all controlled with a single spool valve. This technology has been baselined for the new Orion spacecraft. However, more data was needed on the operational characteristics of the package in a simulated spacecraft environment. A unit was therefore tested with simulated metabolic loads in a closed chamber at Johnson Space Center during the last third of 2006. Those test results were reported in a 2007 ICES paper. A second test article was incorporated for a third phase of testing, and that test article was modified to allow pressurized gas purge regeneration on the launch pad in addition to the standard vacuum regeneration in space. Metabolic rates and chamber volumes were also adjusted to reflect current programmatic standards. The third phase of tests was performed during the spring and summer of 2007. Tests were run with a range of operating conditions, varying: cycle time, vacuum pressure (or purge gas flow rate), air flow rate, and crew activity levels. Results of this testing are presented and potential flight operational strategies discussed.

Lin, Amy↗

Testing of an Amine-Based Pressure-Swing System for Carbon Dioxide and Humidity Control

In a crewed spacecraft environment, atmospheric carbon dioxide (CO2) and moisture control is crucial. Hamilton Sundstrand has developed a stable and efficient amine-based CO2 and water vapor sorbent, SA9T, that is well-suited for use in a spacecraft environment. The sorbent is efficiently packaged in pressure-swing regenerable beds that are thermally linked to improve removal efficiency and minimize vehicle thermal loads. Flows are all controlled with a single spool valve. This technology has been baselined for the new Orion spacecraft. However, more data was needed on the operational characteristics of the package in a simulated spacecraft environment. A unit was therefore tested with simulated metabolic loads in a closed chamber at Johnson Space Center during the last third of 2006. Tests were run at a variety of cabin temperatures and with a range of operating conditions varying cycle time, vacuum pressure, air flow rate, and crew activity levels. Results of this testing are presented and potential flight operational strategies discussed.

Lin, Amy↗

Development of a Test Facility for Air Revitalization Technology Evaluation

Development of new air revitalization system (ARS) technology can initially be performed in a subscale laboratory environment, but in order to advance the maturity level, the technology must be tested in an end-to-end integrated environment. The Air Revitalization Technology Evaluation Facility (ARTEF) at the NASA Johnson Space Center serves as a ground test bed for evaluating emerging ARS technologies in an environment representative of spacecraft atmospheres. At the center of the ARTEF is a hypobaric chamber which serves as a sealed atmospheric chamber for closed loop testing. A Human Metabolic Simulator (HMS) was custom-built to simulate the consumption of oxygen, and production of carbon dioxide, moisture and heat of up to eight persons. A multitude of gas analyzers and dew point sensors are used to monitor the chamber atmosphere upstream and downstream of a test article. A robust vacuum system is needed to simulate the vacuum of space. A reliable data acquisition and control system is required to connect all the subsystems together. This paper presents the capabilities of the integrated test facility and some of the issues encountered during the integration.

Lu, Sao-Dung↗

Development of a Test Facility for Air Revitalization Technology Evaluation

An active fault tolerant control (FTC) law is generally sensitive to false identification since the control gain is reconfigured for fault occurrence. In the conventional FTC law design procedure, dynamic variations due to false identification are not considered. In this paper, an FTC synthesis method is developed in order to consider possible variations of closed-loop dynamics under false identification into the control design procedure. An active FTC synthesis problem is formulated into an LMI optimization problem to minimize the upper bound of the induced-L2 norm which can represent the worst-case performance degradation due to false identification. The developed synthesis method is applied for control of the longitudinal motions of FASER (Free-flying Airplane for Subscale Experimental Research). The designed FTC law of the airplane is simulated for pitch angle command tracking under a false identification case.

Lu, Sao-Dung↗

Sabatier Carbon Dioxide Reduction Assembly Development for Closed Loop Water Recovery

The Sabatier Carbon Dioxide Reduction System (CRA) offers water recovery on a long duration space mission to reduce water resupply. Currently, NASA Johnson Space Center (JSC), NASA Marshall Space Flight Center (MSFC), Hamilton Sundstrand Space Systems International, Inc. (HSSSI), and Southwest Research Institute (SWRI) are working together to develop a Sabatier CRA for the International Space Station (ISS). This effort is being funded by the Office of Biological and Physical Research (Code U)/Advanced Life Support program which is administered by NASA JSC. The Sabatier CRA is the next step in closing the oxygen life support loop on future space missions. The Sabatier reaction combines the waste carbon dioxide (recovered from crew metabolism) with waste hydrogen (a byproduct of electrolysis to produce oxygen) to produce water and methane (CH4). On ISS, the methane would be vented overboard, however the methane can be utilized for propulsion during a planetary exploration mission. Based on a crew size of 7-equivalent people, the Sabatier CRA can produce as much a 2000 lb/year water. Use of the Sabatier CRA will significantly reduce the amount of water that needs to be resupplied to the ISS on a yearly basis, at a tremendous cost saving to the program. Additionally, by recycling this additional water, the Sabatier CRA enables additional launch capacity for science experiments to be brought up to the ISS. The NASA/Industry team noted above has been working to reduce technical risks associated with the Sabatier CRA system. To date the technical risks have been considerably reduced, bringing the Technology Readiness Level (TRL) from TRL 4 to TRL 5/6. In doing so, the team has developed the system schematic, system models, control scheme, produced engineering development unit (EDU) hardware, performed limited integration testing of the EDU's and verified system modeling through testing. Additionally, the system schematic has been evaluated for failure modes and hazards and had a successful technical review by the NASA Safety Board. The current focus is now related to development of the water/methane phase separator, liquid sensor and CO2 compressor piston seal life. The overall goal of the current effort is to bring the system up to a TRL6 by the end of GFY04. Although the Sabatier CRA is not currently baselined for use on the ISS, its benefits are significant enough such that volume within the Oxygen Generation System rack has been reserved for future installation. The value of the water the CRA recover will allow NASA the additional crew time and payload needed to pursue its mission of scientific research.

Smith, Frederick↗