Derivative-Based Global Sensitivity Analysis for Modelswith High-Dimensional Inputs and Functional Output
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Smith, Ralph.
Explore the source record for details and available documents.
The presentation was prepared for the Next-Gen AI for Proliferation Detection: Domain Aware Methods Virtual Workshop.
This chapter introduces several approaches to crystallographic structure refinement from diffraction profile data including the Rietveld method, global optimization methods, and Bayesian modeling. First, the Rietveld method and related nonlinear least squares approaches to analyzing diffraction profiles are briefly discussed. We then review the most common algorithms within global optimization as alternative methods of structure solution: grid search, simulated annealing, and genetic algorithms. As the Rietveld method is the standard tool for analyzing diffraction profile data, we catalogue its challenges and limitations. A Bayesian approach to diffraction profile analysis is presented as an alternative, along with several sampling algorithms including Gibbs sampling, variants of Metropolis sampling, Hamiltonian Monte Carlo, and approximate Bayesian computing. These sampling algorithms are applied to the fitting of a neutron diffraction profile from a National Institute of Standards and Technology silicon standard reference material, and their results are compared.
Detector response functions (DRFs) are often used for inverse analysis. We compute the DRF of a sodium iodide (NaI) nuclear material holdup field detector using the code named g03 developed by the Center for Engineering Applications of Radioisotopes (CEAR) at NC State University. Three measurement campaigns were performed in order to validate the DRF’s constructed by g03: on-axis detection of calibration sources, off-axis measurements of a highly enriched uranium (HEU) disk, and on-axis measurements of the HEU disk with steel plates inserted between the source and the detector to provide attenuation. Furthermore, this work quantifies the uncertainty of the Monte Carlo simulations used in and with g03, as well as the uncertainties associated with each semi-empirical model employed in the full DRF representation. Overall, for the calibration source measurements, the response computed by the DRF for the prediction of the full-energy peak region of responses was good, i.e. within two standard deviations of the experimental response. In contrast, the DRF tended to overestimate the Compton continuum by about 45–65% due to inadequate tuning of the electron range multiplier fit variable that empirically represents physics associated with electron transport that is not modeled explicitly in g03. For the HEU disk measurements, computed DRF responses tended to significantly underestimate (more than 20%) the secondary full-energy peaks (any peak of lower energy than the highest-energy peak computed) due to scattering in the detector collimator and aluminum can, which is not included in the g03 model. We ran a sufficiently large number of histories to ensure for all of the Monte Carlo simulations that the statistical uncertainties were lower than their experimental counterpart’s Poisson uncertainties. The uncertainties associated with least-squares fits to the experimental data tended to have parameter relative standard deviations lower than the peak channel relative standard deviation in most cases and good reduced chi-square values. The highest sources of uncertainty were identified as the energy calibration polynomial factor (due to limited source availability and NaI resolution) and the Ba-133 peak fit (only a very weak source was available), which were 20% and 10%, respectively.
For many simulation models, it can be prohibitively expensive or physically infeasible to obtain a complete set of experimental data to calibrate model parameters. In such cases, one can alternatively employ validated higher-fidelity codes to generate simulated data, which can be used to calibrate the lower-fidelity code. In this paper, we employ an information-theoretic framework to determine the reduction in parameter uncertainty that is obtained by evaluating the high-fidelity code at a specific set of design conditions. These conditions are chosen sequentially, based on the amount of information that they contribute to the low-fidelity model parameters. The goal is to employ Bayesian experimental design techniques to minimize the number of high-fidelity code evaluations required to accurately calibrate the low-fidelity model. We illustrate the performance of this framework using heat and diffusion examples, a 1-D kinetic neutron diffusion equation, and a particle transport model, and include initial results from the integration of the high-fidelity thermal-hydraulics code Hydra-TH with a low-fidelity exponential model for the friction correlation factor.
Not Available
Detector response functions (DRFs) have become the subject of increasing scientific interest for the last thirty years in several industrial applications of radiation detection. These applications include gamma-ray, prompt gamma-ray, and X-ray spectrometry for elemental analysis and location as applied to mining, radio-tracing in medicine, and holdup source characterization. However, it is difficult to create a rigorous mathematical formulation of the DRF. Therefore, semi-empirical and stochastic approaches have been developed instead to construct detector and application specific DRFs. A DRF can be considered to be a function that converts the energy-dependent incidence of incoming source particles onto a detector into a detector response spectrum that simulates the experimental response. The DRF can also be used in the reverse sense in an inverse problem setting, as a step in the process of predicting the physical characteristics of an unknown source (e.g. the holdup problem and library spectra). Much of the recent work on DRFs has been performed by Gardner. He has developed accurate DRF models through semi-empirical curve fitting and Monte Carlo simulation. His DRFs for 3" X 3" NaI detectors have been developed with the experimental measurements taken by Heath and for 6"x6" bare (unshielded) NaI(Tl) detector data with single-energy sources centered on the detector face at a distance of 10 cm. There was agreement with the Heath benchmark detector measurements within two Poisson standard deviations of the measured data. DRFs have also been developed for other detectors such as high purity Germanium detectors and Si(Li) for the same geometries as NaI. Other than a few artifacts such as backscatter peaks, there was good agreement between simulated responses and the experimental data.
Abstract Not Provided