Search NASA⌕ Search

Engineering topics

Smith, S. T.

Publications and source records attributed to Smith, S. T..

Chronocoulometry for quantitative control of mass removal in micro-structures and sensors

In this work, tungsten wires have been etched in a KOH electrolyte solution. Based on the oxidation state of the electrolytic dissolution reaction's product and time integration of the Faradaic current produced during the reaction, this method is capable of providing a direct measurement of the change in mass of a structure from anodic dissolution. To assess the application of this process for controlled mass removal spanning sub-micrograms to milligrams, two experimental studies and accompanying uncertainty analyses have been undertaken. In the first of these, 5 tungsten wires of length 30 mm were used to remove mass values ranging from 50 to 350 {mu}g. Uncertainty estimates indicate relative combined standard uncertainties of less than 0.3% in the mass changes determined from the measurement of Faradaic current. Comparison of the mass change determined using the electrolytic method, and using a precision ultra-microbalance agreed within this uncertainty. The charge-based method was then applied to modify the dynamic characteristics of a quartz tuning fork oscillator. In these experiments, tungsten fiber attached to one tine of the oscillator was etched in 5 {mu}g increments up to 120 {mu}g of total removed mass. In general, frequency shifts of 2.8 Hz{center_dot}{mu}g{sup -1} were observed, indicating sub-microgram resolution for the characterization of probes based on frequency shift and charge-based mass measurement. Taken together, this study provides the basis for a precision method for determining changes in mass based on electrical measurements from an electrochemical system. The utility of this technique is demonstrated through controlled modification of the dynamic properties of a mechanical oscillator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Linear diattenuation of a front-side illuminated CCD

An experiment was performed on a front-side illuminated CCD to measure its linear diattenuation at 550 nm and 650 nm as a function of angle of incidence. The linear diattenuation of the CCD varies from 0 to 12 percent for 550 nm light from 0 to 40 deg and is less for the longer wavelength.

Deslis, A.↗

Shuttle imaging spectrometer optics

This paper discusses the optical design and performance of the Shuttle Imaging Spectrometer (SISEX) optical system, which is being planned for the next generation of Earth remote sensing instruments. This optical system represents a new approach to remote sensing in which wide-field optics, dispersing elements, and area detector arrays are used in place of mechanical scanners, filters, and discrete detector elements or linear arrays. While the SISEX optical system is designed specifically for flight on Shuttle, the same optical approach is being used in the design of other remote sensing instruments, such as the High Resolution Imaging Spectrometer, which is expected to fly on the Earth Observing System.

Page, N. A.↗

Point spread function for a segmented mirror system

A procedure was developed to generate point spread functions for a segmented mirror system for a deployable reflector for submillimeter astronomy. These point spread functions were generated using ACCOS V and special purpose software. This procedure allows tilt and piston sensitivities to be evaluated. Point spread functions with tilt and piston errors are discussed.

Smith, S. T.↗