Search NASA⌕ Search

Engineering topics

Smith, Stephen

Publications and source records attributed to Smith, Stephen.

At least 19 records

The X-ray Integral Field Unit at the end of the Athena reformulation phase

The Athena mission entered a redefinition phase in July 2022, driven by the imperative to reduce the mission cost at completion for the European Space Agency below an acceptable target, while maintaining the flagship nature of its science return. This notably called for a complete redesign of the X-ray Integral Field Unit (X-IFU) cryogenic architecture towards a simpler active cooling chain. Passive cooling via successive radiative panels at spacecraft level is now used to provide a 50 K thermal environment to an X-IFU owned cryostat. 4.5 K cooling is achieved via a single remote active cryocooler unit, while a multi-stage Adiabatic Demagnetization Refrigerator ensures heat lift down to the 50 mK required by the detectors. Amidst these changes, the core concept of the readout chain remains robust, employing Transition Edge Sensor microcalorimeters and a SQUID-based Time-Division Multiplexing scheme. Noteworthy is the introduction of a slower pixel. This enables an increase in the multiplexing factor (from 34 to 48) without compromising the instrument energy resolution, hence keeping significant system margins to the new 4 eV resolution requirement. This allows reducing the number of channels by more than a factor two, and thus the resource demands on the system, while keeping a 4’ field of view (compared to 5’ before). Here, in this article, we will give an overview of this new architecture, before detailing its anticipated performances. Finally, we will present the new X-IFU schedule, with its short term focus on demonstration activities towards a mission adoption in early 2027.

Peille, Philippe [Centre National d’Etudes Spatial↗

Line Emission Mapper: an X-ray probe mission concept to study the cosmic ecosystems and the physics of galaxy formation

In the 2020 Astrophysics Decadal Survey, the National Academies identified cosmic feedback and structure formation as a key question that should drive research in the upcoming decade. In response to this recommendation, NASA released a call for X-ray and IR probe-class missions, with a $\$$1B cost cap. The line emission mapper (LEM) is a mission concept designed in response to this call. LEM is a single-instrument X-ray telescope that consists of a Wolter–Schwarzschild type I X-ray optic with a 4 m focal length, coupled with an X-ray microcalorimeter with a 30' field of view (FoV), 15" angular resolution, and 2.5 eV energy resolution [full-width half maximum (FWHM)], with a 1.3 eV FWHM energy resolution central subarray. The high throughput X-ray mirror combined with the large FoV and excellent energy resolution allows for efficient mapping of extended emission-line dominated astrophysical objects from megaparsecs to sub-pc scales to study cosmic ecosystems and unveil the physical drivers of galaxy formation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Panel Session 25: DOE Waste Isolation Pilot Plant (WIPP) Update 2020

This panel focused on the WIPP operational efficiencies and capital improvement progress in the year 2020. Because WIPP is a key component of the US DOE EM cleanup strategy, the progress on returning WIPP to full design capacity and throughput by 2021 is of importance. Panelists with presentations: Status of WIPP Capital Asset Projects (Stephen Smith); WIPP Update (Sean Dunagan); CBFO Update (Greg Sosson)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Impact of Transition Edge Sensor Design on Achievable Performance Uniformity of Kilo-Pixel Arrays

Future astronomy missions using x-ray transition-edge sensor (TES) microcalorimeters, such as X-IFU on Athena, will require large arrays of 1000s of pixels fabricated on a single wafer. To wire out so many pixels the current array designs have pixels with different rotational orientations. Fabrication is done in multiple layers and so, dependent on method, there is potential for spatial misalignment between layers. Because of the variation of orientation of pixels, misalignment may not impact each pixel equally. This has the potential to degrade the achievable uniformity of performance across an array. How well aligned do different layers need to be? How does sensitivity to misalignment depend on choice of pixel design?

Wakeham, Nicholas↗

Microcalorimeter Array Development for the ATHENA X-Ray Integral Field Unit

The X-ray integral field unit (X-IFU) for ESA's Athena X-ray observatory will consist of 3840 AC-biased transition edge sensors (TESs), read out using frequency domain multiplexing (FDM). In this paper we describe details of the latest pixels geometries that are being designed for the current baseline array configuration. This includes details on how important TES properties (transition parameters, thermal design of the pixels, absorber composition) are being optimized to meet the target energy resolution, count-rate and quantum efficiency. We also present the latest design optimizations specifically targeted at mitigating AC-bias phenomena in Mo/Au TESs that can degrade performance.

Smith, Stephen↗

PE-46 The Design of the Lynx X-Ray Microcalorimeter

Lynx is an x-ray telescope, one of four large satellite mission concepts currently being studied by NASA to be the next astrophysics flagship mission after WFIRST. One of Lynx's three instruments is an imaging spectrometer consisting of an x-ray microcalorimeter behind an X-ray optic with an angular resolution of 0.5 arc-seconds and approximately 3 sq m of area at 1 keV. This instrument will provide unparalleled diagnostics of distant extended structures and in particular will allow the detailed study of the role of cosmic feedback in the evolution of the Universe. We discuss the design and read-out of the of the array configuration including a number of sub-array options for increasing the capabilities to maximize the scientific return of the Lynx observatory.

Bandler, Simon↗

The Athena X-ray Integral Field Unit (X-IFU)

The X-ray Integral Field Unit (X-IFU) on board the Advanced Telescope for High-ENergy Astrophysics (Athena) will provide spatially resolved high-resolution X-ray spectroscopy from 0.2 to 12 keV, with 5 pixels over a field of view of 5 arc minute equivalent diameter and a spectral resolution of 2.5 eV up to 7 keV. In this paper, we first review the core scientific objectives of Athena, driving the main performance parameters of the X-IFU, namely the spectral resolution, the field of view, the effective area, the count rate capabilities, the instrumental background. We also illustrate the breakthrough potential of the X-IFU for some observatory science goals. Then we brie y describe the X-IFU design as defined at the time of the mission consolidation review concluded in May 2016, and report on its predicted performance. Finally, we discuss some options to improve the instrument performance while not increasing its complexity and resource demands (e.g. count rate capability, spectral resolution). (2016) .

Space telescopes↗

Model reduction for stochastic chemical systems with abundant species

Biochemical processes typically involve many chemical species, some in abundance and some in low molecule numbers. We first identify the rate constant limits under which the concentrations of a given set of species will tend to infinity (the abundant species) while the concentrations of all other species remains constant (the non-abundant species). Subsequently, we prove that, in this limit, the fluctuations in the molecule numbers of non-abundant species are accurately described by a hybrid stochastic description consisting of a chemical master equation coupled to deterministic rate equations. This is a reduced description when compared to the conventional chemical master equation which describes the fluctuations in both abundant and non-abundant species. We show that the reduced master equation can be solved exactly for a number of biochemical networks involving gene expression and enzyme catalysis, whose conventional chemical master equation description is analytically impenetrable. We use the linear noise approximation to obtain approximate expressions for the difference between the variance of fluctuations in the non-abundant species as predicted by the hybrid approach and by the conventional chemical master equation. Furthermore, we show that surprisingly, irrespective of any separation in the mean molecule numbers of various species, the conventional and hybrid master equations exactly agree for a class of chemical systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental Characterization and Simulation of Slip Transfer at Grain Boundaries and Microstructurally-Sensitive Crack Propagation

A systematic study of crack tip interaction with grain boundaries is critical for improvement of multiscale modeling of microstructurally-sensitive fatigue crack propagation and for the computationally-assisted design of more durable materials. In this study, single, bi- and large-grain multi-crystal specimens of an aluminum-copper alloy are fabricated, characterized using electron backscattered diffraction (EBSD), and deformed under tensile loading and nano-indentation. 2D image correlation (IC) in an environmental scanning electron microscope (ESEM) is used to measure displacements near crack tips, grain boundaries and within grain interiors. The role of grain boundaries on slip transfer is examined using nano-indentation in combination with high-resolution EBSD. The use of detailed IC and EBSD-based experiments are discussed as they relate to crystal-plasticity finite element (CPFE) model calibration and validation.

Gupta, Vipul↗

Designing the X-Ray Microcalorimeter Spectrometer for Optimal Science Return

Recent advances in X-ray microcalorimeters enable a wide range of possible focal plane designs for the X-ray Microcalorimeter Spectrometer (XMS) instrument on the future Advanced X-ray Spectroscopic Imaging Observatory (AXSIO) or X-ray Astrophysics Probe (XAP). Small pixel designs (75 microns) oversample a 5-10" PSF by a factor of 3-6 for a 10 m focal length, enabling observations at both high count rates and high energy resolution. Pixel designs utilizing multiple absorbers attached to single transition-edge sensors can extend the focal plane to cover a significantly larger field of view, albeit at a cost in maximum count rate and energy resolution. Optimizing the science return for a given cost and/or complexity is therefore a non-trivial calculation that includes consideration of issues such as the mission science drivers, likely targets, mirror size, and observing efficiency. We present a range of possible designs taking these factors into account and their impacts on the science return of future large effective-area X-ray spectroscopic missions.

X-rays↗

Design of High Resolution Soft X-Ray Microcalorimeters Using Magnetic Penetration Thermometers

We have designed high-resolution soft x-ray microcalorimeters using magnetic penetration thermometers (MPTs) in an array of pixels covering a total of 2 square centimeters to have a resolving power of 300 at energies around 300 eV. This performance is desirable for studying the soft x-ray background from the warm hot intergalactic medium. MPT devices have small sensor heat capacity and high responsivities, which makes them excellent detector technology for attempting to attain sub-eV resolution. We are investigating the feasibility of pixels with absorbers that are 625 x 625 square micrometers, up to 1 x 1 square millimeters in area and 0.35 micrometer thick and thinner. Our tests have shown that suspended gold absorbers 0.35 micrometers thick (RRR = 6.7) are feasible to fabricate. We modeled the thermal diffusion from such thin gold over the size of a 625 x 625 square micrometer absorber, and conclude that the effect of the thermalization on the resolution of a 300 eV photon is an additional approximately 0.2 eV FWHM of broadening. We discuss the thermal effects of small absorber attachment sterns on solid substrate, as well as considerations for multiplexed readout. We will present the progress we have made towards building and testing this soft x-ray detector.

Busch. Sarah↗

High Broadband Spectral Resolving Transition-Edge Sensors for High Count-Rate Astrophysical Applications

We are developing arrays of transition-edge sensor (TES) X-ray detectors optimized for high count-rate solar astronomy applications where characterizing the high velocity motions of X-ray jets in solar flares is of particular interest. These devices are fabricated on thick Si substrates and consist of 35x35micron^2 TESs with 4.5micron thick, 60micron pitch, electroplated absorbers. We have tested devices fabricated with different geometric stem contact areas with the TES and surrounding substrate area, which allows us to investigate the loss of athermal phonons to the substrate. Results show a correlation between the stem contact area and a non-Gaussian broadening in the spectral line shape consistent with athermal phonon loss. When the contact area is minimized we have obtained remarkable board-band spectral resolving capabilities of 1.3 plus or minus 0.leV at an energy of 1.5 keV, 1.6 plus or minus 0.1 eV at 5.9 keV and 2.0 plus or minus 0.1 eV at 8 keV. This, coupled with a capability of accommodating 100's of counts per second per pixel makes these devices an exciting prospect of future x-ray astronomy applications.

Smith, Stephen↗

Characterizing Weak-Link Effects in Mo/Au Transition-Edge Sensors

We are developing Mo/Au bilayer transition-edge sensors (TESs) for applications in X-ray astronomy. Critical current measurements on these TESs show they act as weak superconducting links exhibiting oscillatory, Fraunhofer-like, behavior with applied magnetic field. In this contribution we investigate the implications of this behavior for TES detectors, under operational bias conditions. This includes characterizing the logarithmic resistance sensitivity with temperature, (alpha, and current, beta, as a function of applied magnetic field and bias point within the resistive transition. Results show that these important device parameters exhibit similar oscillatory behavior with applied magnetic field, which in turn affects the signal responsivity, noise and energy resolution.

Smith, Stephen↗

Modelling of TES X-ray Microcalorimeters with a Novel Absorber Design

Our development of a novel x-ray absorber design that has enabled the incorporation of high-conductivity electroplated gold into our absorbers has yielded devices that not only have achieved breakthrough performance at 6 keV, but also are extraordinarily well modelled. We have determined device parameters that reproduce complex impedance curves and noise spectra throughout transition. Observed pulse heights, decay time and baseline energy resolution were in good agreement with simulated results using the same parameters. In the presentation, we will show these results in detail and we will also show highlights of the characterization of our gold/bismuth-absorber devices. We will discuss possible improvement of our current devices and expected performance of future devices using the modelling results.

Iyomoto, Naoko↗

Heat Sinking, Cross Talk, and Temperature Stability for Large, Close-Packed Arrays of Microcalorimeters

We are developing large, close-packed arrays of x-ray transition-edge sensor (TES) microcalorimeters. In such a device, sufficient heat sinking is important to to minimize thermal cross talk between pixels and to stabilize the bath temperature for all pixels. We have measured cross talk on out 8 x 8 arrays and studied the shape and amount of thermal crosstalk as a function of pixel location and efficiency of electrothermal feedback. In this presentation, we will compare measurements made on arrays with and without a backside, heat-sinking copper layer, as well as results of devices on silicon-nitride membranes and on solid substrates, and we will discuss the implications for energy resolution and maximum count rate. We will also discuss the dependence of pulse height upon bath temperature, and the measured and required stability of the bath temperature.

Imoto, Naoko↗

Studies of the Superconducting Transition in the Mo/Au-Bilayer Thin Films

At NASA Goddard, microcalorimeter arrays using superconducting transition edge sensor thermometers (TESs) are under development for high energy resolution X-ray astrophysics applications. We report on our studies of the superconducting transition in our Mo/Au-bilayer TES films including: low current measurements of the superconducting bilayer's resistance transition versus temperature on pixels with different normal metal absorber attachment designs and measured temperature scaling of the critical current and critical magnetic field.

Sadleir, John↗

Absorber Materials for Transition-Edge Sensor X-ray Microcalorimeters

Arrays of superconducting transition-edge sensors (TES) can provide high spatial and energy resolution necessary for x-ray astronomy. High quantum efficiency and uniformity of response can be achieved with a suitable absorber material, in which absorber x-ray stopping power, heat capacity, and thermal conductivity are relevant parameters. Here we compare these parameters for bismuth and gold. We have fabricated electroplated gold, electroplated gold/electroplated bismuth, and evaporated gold/evaporated bismuth 8x8 absorber arrays and find that a correlation exists between the residual resistance ratio (RRR) and thin film microstructure. This finding indicates that we can tailor absorber material conductivity via microstructure alteration, so as to permit absorber thermalization on timescales suitable for high energy resolution x-ray microcalorimetry. We show that by incorporating absorbers possessing large grain size, including electroplated gold and electroplated gold/electroplated bismuth, into our current Mo/Au TES, devices with tunable heat capacity and energy resolution of 2.3 eV (gold) and 2.1 eV (gold/bismuth) FWHM at 6 keV have been fabricated.

Brown, Ari-David↗