Non-Intrusive Pressure/Multipurpose Sensor and Method

Method and apparatus are provided for determining pressure using a non-intrusive sensor that is easily attachable to the plumbing of a pressurized system. A bent mode implementation and a hoop mode implementation of the invention are disclosed. Each of these implementations is able to nonintrusively measure pressure while fluid is flowing. As well, each implementation may be used to measure mass flow rate simultaneously with pressure. An ultra low noise control system is provided for making pressure measurements during gas flow. The control system includes two tunable digital bandpass filters with center frequencies that are responsive to a clock frequency. The clock frequency is divided by a factor of N to produce a driving vibrational signal for resonating a metal sensor section.

Smith, William C.

Microstrip-Transmission-Line Shock-Front Sensor

Microstrip-transmission-line sensor measures velocities of low-overpressure shock fronts and offers dynamic range needed for measurements both far from and near explosions. Fabricated easily, relatively inexpensive, and repaired in field. In addition, basic geometry modified easily, as needed.

Leiweke, Robert J.

Laser-Power Controller

New controller used in place of commercial controller. Provides precision and simplicity of digital settings, and all timing determined by digital circuits. Built-in circuit counts number of pulses in, and thereby provides control over, duration of each burst; duration set at precise value within wide range or each pulse set precisely. Controller easily adaptable to computer control: single switch used to select either manual or computer control. Another single-switch selection feature provides choice between counting of pulses in, and manual timing of, bursts.

Smith, William C.

Response of a piezoelectric pressure transducer to IR laser beam impingement

The non-pressure response of a PCB Model 113A transducer to a far infrared radiation impulse from a carbon dioxide laser was investigated. Incident radiation was applied both to the bare transducer diaphragm and to coated diaphragms. Coatings included two common ablative materials and a reflective gold coating. High-flux radiation impulses induced an immediate brief negative output followed by a longer-duration positive output. Both timing and amplitude of the responses will be discussed, and the effects of coatings will be compared. Bursts of blackbody radiation from a 1500 K source produced qualitatively similar responses.

Smith, William C.

Electrostatic discharge test apparatus

Electrostatic discharge properties of materials are quantitatively measured and ranked. Samples (20) are rotated on a turntable (15) beneath selectable, co-available electrostatic chargers (30/40), one being a corona charging element (30) and the other a sample-engaging triboelectric charging element (40). They then pass under a voltage meter (25) to measure the amount of residual charge on the samples (20). After charging is discontinued, measurements are continued to record the charge decay history over time.

Smith, William C.

Measuring Electrostatic Discharge

Apparatus measures electrostatic-discharge properties of several materials at once. Allows samples charged either by friction or by exposure to corona. By testing several samples simultaneously, apparatus eliminates errors introduced by variations among test conditions. Samples spaced so they pass at intervals under either of two retractable arms. Samples are 2 inches wide along circular path. Arm tips and voltmeter probe are 6 inches from turntable center. Servocontrolled turntable speed constant within 0.1 percent.

Smith, William C.