Calibration Tests of Industrial and Scientific CCD Cameras

Small format, medium resolution CCD cameras are at present widely used for industrial metrology applications. Large format, high resolution CCD cameras are primarily in use for scientific applications, but in due course should increase both the range of applications and the object space accuracy achievable by close range measurement. Slow scan, cooled scientific CCD cameras provide the additional benefit of additional quantisation levels which enables improved radiometric resolution. The calibration of all types of CCD cameras is necessary in order to characterize the geometry of the sensors and lenses. A number of different types of CCD cameras have been calibrated a the NASA Langley Research Center using self calibration and a small test object. The results of these calibration tests will be described, with particular emphasis on the differences between standard CCD video cameras and scientific slow scan CCD cameras.

Shortis, M. R.

Laboratory calibration and characterization of video cameras

Some techniques for laboratory calibration and characterization of video cameras used with frame grabber boards are presented. A laser-illuminated displaced reticle technique (with camera lens removed) is used to determine the camera/grabber effective horizontal and vertical pixel spacing as well as the angle of nonperpendicularity of the axes. The principal point of autocollimation and point of symmetry are found by illuminating the camera with an unexpanded laser beam, either aligned with the sensor or lens. Lens distortion and the principal distance are determined from images of a calibration plate suitably aligned with the camera. Calibration and characterization results for several video cameras are presented. Differences between these laboratory techniques and test range and plumb line calibration are noted.

Burner, A. W.

Laboratory Calibration and Characterization of Video Cameras

Some techniques for laboratory calibration and characterization of video cameras used with frame grabber boards are presented. A laser-illuminated displaced reticle technique (with camera lens removed) is used to determine the camera/grabber effective horizontal and vertical pixel spacing as well as the angle of non-perpendicularity of the axes. The principal point of autocollimation and point of symmetry are found by illuminating the camera with an unexpanded laser beam, either aligned with the sensor or lens. Lens distortion and the principal distance are determined from images of a calibration plate suitable aligned with the camera. Calibration and characterization results for several video cameras are presented. Differences between these laboratory techniques and test range and plumb line calibration are noted.

Burner, A. W.

A digital video model deformation system

The use of solid-state array cameras and a PC-controlled image acquisition system to measure model deformation in a wind tunnel is discussed. This digital system improves an earlier video model deformation system that used high-resolution tube cameras and required the manual measurement of targets on video hardcopy images. The new system eliminates both the vibration-induced distortion associated with tube cameras and the manual readup of video images necessary in the earlier version. Camera calibration and data reduction procedures necessary to convert pixel image plane data from two cameras into wing deflections are presented. Laboratory tests to establish the uncertainty of the system with the geometry to be used are described.

Burner, A. W.

Improvement in the quality of flow visualization in the Langley 0.3-meter transonic cryogenic tunnel

Optical diagnostic techniques have not been as successful in the 0.3-Meter Transonic Cryogenic Tunnel as in conventional wind tunnels. This paper describes a simple shadowgraph experiment which allowed evacuation of the optical paths outside the test section. The results show that refractive index variations induced by temperature gradients outside the test section account for most of the image degradation. Earlier reports had erroneously attributed this degradation to inhomogeneities in the test section. Evacuation of the paths leading to and from the test section significantly improves the quality of flow visualization.

Snow, W. L.

A Digital Video Model Deformation System

The use of slid-state array cameras and a PC controlled image acquisition system to measure model deformation in a wind tunnel is discussed. This digital system is an improvement to an earlier video model deformation system used at the National Transonic Facility (NTF) which employed high-resolution tube cameras and required the manual measurement of targets on video hardcopy images. The new system eliminates both the vibration-induced distortion associated with tube cameras and the manual readup of video images necessary in the earlier version. Camera calibration and data reduction procedures necessary to convert pixel image plane data from two cameras into wing deflections are presented. Laboratory tests to establish the uncertainty of the new system with the geometry to be used at the NTF are described.

Burner, A. W.

Model deformation measurements at a cryogenic wind tunnel using photogrammetry

A photogrammetric closed circuit television system to measure model deformation at the National Transonic Facility (NTF) is described. The photogrammetric approach was chosen because of its inherent rapid data recording of the entire object field. Video cameras are used to acquire data instead of film cameras due to the inaccessibility of cameras which must be housed within the cryogenic, high pressure plenum of this facility. Data reduction procedures and the results of tunnel tests at the NTF are presented.

Burner, A. W.

Close-range photogrammetry with video cameras

Examples of photogrammetric measurements made with video cameras uncorrected for electronic and optical lens distortions are presented. The measurement and correction of electronic distortions of video cameras using both bilinear and polynomial interpolation are discussed. Examples showing the relative stability of electronic distortions over long periods of time are presented. Having corrected for electronic distortion, the data are further corrected for lens distortion using the plumb line method. Examples of close-range photogrammetric data taken with video cameras corrected for both electronic and optical lens distortion are presented.

Burner, A. W.

Investigation of light source and scattering medium related to vapor-screen flow visualization in a supersonic wind tunnel

Methods for increasing the radiant in light sheets used for vapor screen set-ups were investigated. Both high-pressure mercury arc lamps and lasers were considered. Pulsed operation of the air-cooled 1-kW lamps increased the light output but decreased reliability. An ellipsoidal mirror improved the output of the air-cooled lamps by concentrating the light but increased the complexity of the housing. Water-cooled-4-kW lamps coupled with high-aperture Fresnel lenses provided reasonable improvements over the air-cooled lamps. Fanned laser beams measurements of scattered light versus dew point made in conjunction with successful attempts to control the fluid injection. A number of smoke generators are described and test results comparing smoke and vapor screens are shown. Finally, one test included a periscope system to relay the image to a camera outside the flow.

Snow, W. L.

Video model deformation system for the National Transonic Facility

A photogrammetric closed circuit television system to measure model deformation at the National Transonic Facility is described. The photogrammetric approach was chosen because of its inherent rapid data recording of the entire object field. Video cameras are used to acquire data instead of film cameras due to the inaccessibility of cameras which must be housed within the cryogenic, high pressure plenum of this facility. A rudimentary theory section is followed by a description of the video-based system and control measures required to protect cameras from the hostile environment. Preliminary results obtained with the same camera placement as planned for NTF are presented and plans for facility testing with a specially designed test wing are discussed.

Burner, A. W.

Close-Range Photogrammetry with Video Cameras

Examples of photogrammetric measurements made with video cameras uncorrected for electronic and optical lens distortions are presented. The measurement and correction of electronic distortions of video cameras using both bilinear and polynomial interpolation are discussed. Examples showing the relative stability of electronic distortions over long periods of time are presented. Having corrected for electronic distortion, the data are further corrected for lens distortion using the plumb line method. Examples of close-range photogrammetric data taken with video cameras corrected for both electronic and optical lens distortion are presented.

Burner, A. W.

Image degradation in Langley 0.3-meter transonic cryogenic tunnel

The optical quality of gas in a cryogenic wind tunnel was determined by observing Sayce targets through different pathlengths of the medium. The data were used to determine the square wave response of the test gas. At conditions corresponding to 15 times ambient density, considerable decrease in response to higher spatial frequencies was noted even in the absence of flow. Under flow conditions, vibrations further degraded the response. The results are interpreted in terms of possible photogrammetric approaches to measure model deformation in large cryogenic facilities such as the National Transonic Facility.

Snow, W. L.

Seeing through flows in Langley's 0.3-meter Transonic Cryogenic Tunnel

Viewing problems associated with the measurement of model deformation in cryogenic wind tunnels are discussed. Tests were conducted in the Langley 0.3-Meter Transonic Cryogenic Tunnel to assess viewing capabilities thru the flow field. The effects of condensation and turbulent boundary layers are discussed and a modelling procedure for image degradation is described.

Snow, W. L.

Flow field studies using holographic interferometry at Langley

Some of the uses of holographic interferometry at Langley Research Center both for flow visualization and for density field determinations are described and tests in cryogenic flows at the Langley 0.3-Meter Transonic Cryogenic Tunnel are discussed. Experimental and theoretical fringe shift data are compared.

Burner, A. W.

Use of a variable exposure photographic pyrometer to measure surface temperatures on a hemispherical-face model

The use of a photographic pyrometer for nonintrusive measurement of high temperature surfaces in a wind tunnel test is described. The advantages of the pyrometer for measuring surfaces whose unique shape makes use of thermocouples difficult are pointed out. The use of computer operated densitometers or optical processors for the data reduction is recommended.

Kantsios, A. G.

Model Deformation Measurements at a Cryogenic Wind Tunnel Using Photogrammetry

A photogrammetric closed circuit television system to measure model deformation at the National Transonic Facility (NTF) is described. The photogrammetric approach was chosen because of its inherent rapid data recording of the entire object field. Video cameras are used to acquire data instead of film cameras due to the inaccessibility of cameras which must be housed within the cryogenic, high pressure plenum of this facility. Data reduction procedures and the results of tunnel tests at the NTF are presented.

Burner, A. W.

Dynamic Moire Methods for Detection of Loosened Space Shuttle Tiles

Moire fringe methods for detecting loose space shuttle tiles were investigated with a test panel consisting of a loose tile surrounded by four securely bonded tiles. The test panel was excited from 20 to 150 Hz with in-plane sinusoidal acceleration of 2 g (peak). If the shuttle orbiter can be subjected to periodic excitation of 1 to 2 g (peak) and rigid-body periodic displacements do not mask the change in the Moire pattern due to tile looseness, then the use of projected Moire fringes to detect out-of-plane rockin appears to be the most viable indicator of tile looseness since no modifications to the tiles are required.

Snow, W. L.

The spectral opacity of triatomic carbon measured in a graphite tube furnace over the 280 to 600 nm wavelength range

The paper presents the measurements of linear triatomic carbon opacity (C3) made in a graphite tube furnace to extend the wavelength range of Brewer and Engelke (1962) to the 280-600 nm range. An electrooptical method was used to determine C3 absorption in argon at 2720 to 3060 K; a quartic polynomial regression expression was derived to provide a complete temperature profile from pyrometer measurements. The C3 spectra were plotted for several opacity levels. It was concluded that the extension of the spectral range to the near u.v. levels made it easier to identify C3 particles.

Snow, W. L.