Search NASA⌕ Search

Engineering topics

Snyder, Lucas

Publications and source records attributed to Snyder, Lucas.

Templates of expected measurement uncertainties

The covariance committee of CSEWG (Cross Section Evaluation Working Group) established templates of expected measurement uncertainties for neutron-induced total, (n,γ), neutron-induced charged-particle, and (n,xn) reaction cross sections as well as prompt fission neutron spectra, average prompt and total fission neutron multiplicities, and fission yields. Templates provide a list of what uncertainty sources are expected for each measurement type and observable, and suggest typical ranges of these uncertainties and correlations based on a survey of experimental data, associated literature, and feedback from experimenters. Information needed to faithfully include the experimental data in the nuclear-data evaluation process is also provided. These templates could assist (a) experimenters and EXFOR compilers in delivering more complete uncertainties and measurement information relevant for evaluations of new experimental data, and (b) evaluators in achieving a more comprehensive uncertainty quantification for evaluation purposes. This effort might ultimately lead to more realistic evaluated covariances for nuclear-data applications. In this topical issue, we cover the templates coming out of this CSEWG effort–typically, one observable per paper. This paper here prefaces this topical issue by introducing the concept and mathematical framework of templates, discussing potential use cases, and giving an example of how they can be applied (estimating missing experimental uncertainties of 235 U(n,f) average prompt fission neutron multiplicities), and their impact on nuclear-data evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the 239 Pu(n,f)/ 235 U(n,f) Cross-Section Ratio with the NIFFTE fission Time Projection Chamber

In this work, the 239 Pu(n,f)/ 235 U(n,f) cross-section ratio has been measured with the fission Time Projection Chamber (fissionTPC) from 100 keV to 100 MeV. The fissionTPC provides three-dimensional reconstruction of fission-fragment ionization profiles, allowing for a precise quantification of measurement uncertainties. The measurement was performed at the Los Alamos Neutron Science Center which provides a pulsed white source of neutrons. The data are recommended to be used as a cross-section ratio shape. A discussion of the status of the absolute normalization and comparisons to ENDF evaluations and previous measurements is included.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fission TPC cross section ratio results [Abstract]

The fission TPC was designed for precision fission cross section ratio measurements. The high-fidelity 3D particle tracking data is used to conduct a detailed analysis of the uncertainty contributions. In this contribution a brief overview of the instrument was presented. The results of the 238 U(n,f)/ 235 U(n,f) cross section ratio measurement published in [Phys. Rev C 97, 034618 (2018)] were reviewed and the preliminary status of the 239 Pu(n,f)/ 235 U(n,f) cross section ratio measurement was shown.

238U(n,f)/235U(n,f) cross section ratio↗