Search NASA⌕ Search

Engineering topics

Solyak, Nikolay

Publications and source records attributed to Solyak, Nikolay.

53 records · Page 3

A Two-stage Injection-locked Magnetron for Accelerators with Superconducting Cavities

A concept for a two-stage injection-locked CW magnetron intended to drive Superconducting Cavities (SC) for intensity-frontier accelerators has been proposed. The concept considers two magnetrons in which the output power differs by 15-20 dB and the lower power magnetron being frequency-locked from an external source locks the higher power magnetron. The injection-locked two-stage CW magnetron can be used as an RF power source for Fermilab's Project-X to feed separately each of the 1.3 GHz SC of the 8 GeV pulsed linac. We expect output/locking power ratio of about 30-40 dB assuming operation in a pulsed mode with pulse duration of ~ 8 ms and repetition rate of 10 Hz. The experimental setup of a two-stage magnetron utilising CW, S-band, 1 kW tubes operating at pulse duration of 1-10 ms, and the obtained results are presented and discussed in this paper.

43 PARTICLE ACCELERATORS↗

Status of the Design of 650 MHz Elliptical Cavities for Project X

Project X is a proposed high-intensity proton accelerator complex that could provide beam to create a high-intensity neutrino beam, feed protons to kaon- and muon-based precision experiments, and for other applications still under investigation. The present configuration of the proton accelerator foresees a section with 650 MHz β = 0.6 and β = 0.9 elliptical cavities. Prototypes of single-cell 650 MHz cavities and five-cell β = 0.9 650 MHz cavities are being designed and fabricated at Fermilab in the R&D process for Project X. This paper summarizes the design status of the β = 0.6 and β = 0.9 single-cell prototype cavities, and also addresses the design effort focused on the five-cell β = 0.9 cavities.

43 PARTICLE ACCELERATORS↗

Three-cell traveling wave superconducting test structure

Use of a superconducting traveling wave accelerating (STWA) structure with a small phase advance per cell rather than a standing wave structure may provide a significant increase of the accelerating gradient in the ILC linac. For the same surface electric and magnetic fields the STWA achieves an accelerating gradient 1.2 larger than TESLA-like standing wave cavities. The STWA allows also longer acceleration cavities, reducing the number of gaps between them. However, the STWA structure requires a SC feedback waveguide to return the few hundreds of MW of circulating RF power from the structure output to the structure input. A test single-cell cavity with feedback was designed, manufactured and successfully tested demonstrating the possibility of a proper processing to achieve a high accelerating gradient. These results open way to take the next step of the TW SC cavity development: to build and test a travelingwave three-cell cavity with a feedback waveguide. The latest results of the single-cell cavity tests are discussed as well as the design of the test 3-cell TW cavity.

43 PARTICLE ACCELERATORS↗

650 MHz Option for High-energy Part of the Project X linac

650 MHz option for the high energy part of the 3 GeV, CW Project X linac is discussed. It may give significant benefits compared to current 1.3 GHz option based on the utilization of ILC-type beta=1 cavities. Results of the break point optimization for linac stages and cavity optimization are presented. Possible reduction in the number of cryomodules and linac length compared to the current linac project version is discussed. Cryogenic losses are analyzed also.

43 PARTICLE ACCELERATORS↗

Lattice Design for Project -X CW Superconducting Linac

In this paper, we discuss the beam dynamics optimization of a proposed continuous wave (CW) superconducting linac for Project-X. This 3.0 GeV linac has a peak current of 5-10 mA. The average current is 1 mA, yielding an average beam power of 3 MW. The linac consists of a low energy 325 MHz section (2.5 -470 MeV) containing three families of SC single-spoke resonators, an intermediate energy section (470 MeV-2.0 GeV) containing two families (βg = 0.61 and βg = 0.9) of 650 MHz squeezed SC elliptical cavities and finally, a high energy section (2.0-3.0 GeV) based on 1.3GHz ILC-type (βg = 1.0) cavities. Transverse and longitudinal dynamics in the CW linac are modeled assuming the maximum 1 mA peak current. Different options for transverse focusing are considered.

43 PARTICLE ACCELERATORS↗

Study of Coupler's Effects on ILC Like Lattice

It is well known that insertion of a coupler into a rf cavity breaks the rotational symmetry of the cavity, resulting in an asymmetric field. This asymmetric field results in a transverse RF Kick. This RF kick transversely offsets the bunch from the nominal axis & it depends on the longitudinal position of the particle in the bunch. Also, insertion of coupler generates short range transverse wake field which is independent from the transverse offset of the particle. These effects cause emittance dilution and it is thus important to study their behaviour & possible correction mechanisms. These coupler effects, i.e. coupler’s RF kick & coupler's wake field are implemented in a beam dynamics program, Lucretia. Simulations are performed for main linac & bunch compressor of International Linear Collider (ILC) like lattices. Results are compared with analytical results and another beam dynamics code Placet. The good agreement has been achieved.

43 PARTICLE ACCELERATORS↗

The Beam Splitter for the Project X

In the Project X facility, a 3 GeV, H- CW beam is delivered to three users simultaneously by way of selectively filling appropriate RF buckets at the front end of the linac and then RF splitting them to three different target halls. With the desire to split the H- beam three ways, an RF separator directs two quarters of the beam to one user (Mu2e), one quarter to another user (Kaon), and one quarter to the third (unidentified) user. The natural way is to use a SC structure with the deflecting TM110 mode. Basic requirements to the deflecting RF structure are formulated and design of the deflecting SC cavities is presented.

43 PARTICLE ACCELERATORS↗

Designing of 9 Cell Reduced Beta Elliptical Cavity for High Intensity Proton Linac

A superconducting rf cavity is designed for acceleration of particles travelling at 81% of the speed of light (beta=0.81). This 1.3 GHz cavity will be used in the SILC section of the proposed high intensity proton linac at Fermilab and will accelerate particles in the energy range of 466 MeV to 1.2 GeV. It will be shorter than 9 cells, beta =1 cavity but it will have nearly same ratio of the surface magnetic field to the surface electric field. The inter cell to cell coupling coefficient is also optimized to get good field flatness. Both longitudinal and transverse higher order modes are studied. The shapes of end cells are optimized to avoid dangerous modes while keeping same field flatness & same operating frequency as for ILC type cavity.

43 PARTICLE ACCELERATORS↗

First High-gradient Tests of the Single-cell SC Cavity with the Feedback Waveguide

Use of a superconducting travelling wave accelerating (STWA) structure with a small phase advance per cell rather than a standing wave structure may provide a significant increase in the accelerating gradient in the ILC linac [1]. For the same surface electric and magnetic fields the STWA achieves an accelerating gradient 1.2 larger than TESLA-like standing wave cavities. In addition, the STWA allows longer acceleration cavities, reducing the number of gaps between them. However, the STWA structure requires a SC feedback waveguide to return the few hundreds of MW of circulating RF power from the structure output to the structure input. A test single-cell cavity with feedback was designed and manufactured to demonstrate the possibility of a proper processing to achieve a high accelerating gradient. The first results of high-gradient tests of a prototype 1.3 GHz single-cell cavity with feedback waveguide will be presented.

43 PARTICLE ACCELERATORS↗

The Concept Design of the CW Linac of the Project X

The concept design of the 3 GeV superconducting CW linac of the Project X is discussed. The linac structure and break points for different cavity families are described. The results of the RF system optimization are presented as well as the lattice design and beam dynamics analysis.

43 PARTICLE ACCELERATORS↗

Single-Stage Bunch Compressor for ILC-SB2009

The Project Management Design Team of the International Linear Collider has recently proposed fundamental changes to the published ILC RDR baseline with the goal of presenting a potential alternate design providing a more cost-effective solution. In this framework a new lattice for the Damping Rings has been presented, shortening the exit bunch length from the RDR value of 9 mm down to 6 mm. The shorter bunch length allowed the adoption of a simpler single-stage bunch compressor, instead of the RDR two-stage compressor. The new single-stage compressor has a compression ratio of 20 and still achieves the nominal RDR value of 0.3 mm bunch length at the Interaction Point. The new design has been optimized to generate the required compression while having a small SR emittance growth, and reduced energy spread. The new lattice and its optimization procedure are presented in this paper.

43 PARTICLE ACCELERATORS↗

Longitudinal and Transverse Effects of HOMs in the Project X Linac

Results of analysis are presented for the longitudinal and transverse effects of High-Order Mode (HOM) excitation in the acceleration RF system of the CW proton linac of the Project X facility. Necessity of HOM dampers in the SC cavities of the linac is discussed.

43 PARTICLE ACCELERATORS↗

A Spin Rotator for the Compact Linear Collider

Polarized positron and electron beams are ideal for searching for new physics at the Compact Linear Collider (CLIC). In order to properly orient and preserve the polarization of the beam at the interaction point, the beam polarization must be manipulated by a spin rotator along the beam line. In this paper a spin rotator design for the CLIC is presented and its integration into the CLIC ring to main linac transport system is discussed

43 PARTICLE ACCELERATORS↗

Optimization of End Cells of Low Beta Cavity of Higher Energy Part of Project X

11 cell elliptical cavity is designed for acceleration of particles travelling at 81 % of the speed of light. It will operate at 1.3 GHz & will be served to accelerate the particles from 0.450 GeV to 1.2 GeV in high energy section of Project-X. The cavity is studied for higher order mode (HOM) & trapped modes. The shapes of end cells of cavity is optimized to increase the field amplitude in end cells so that coupling of trapped modes may increase with HOM coupler & they can be extracted easily but keeping the field flatness & operating frequency undisturbed.

43 PARTICLE ACCELERATORS↗

Single Spoke Cavities for Low-energy Part of CW Linac of Project X.

In the low-energy part of the Project X H-linac three families of 325 MHz SC single spoke cavities will be used, having {beta} = 0.11, 0.21 and 0.4. Single spoke cavity was selected for the linac because of higher r/Q. Results of optimization of all cavities are presented. Results of the beam dynamics optimization for initial stage of the linac with beta=0.11 single spoke cavity are presented at poster MOPEC082 (this conference).

43 PARTICLE ACCELERATORS↗

Final Results on RF and Wake Kicks Caused by the Couplers for the ILC Cavity

In the paper the results are presented for calculation of the transverse wake and RF kick from the power and HOM couplers of the ILC acceleration structure. The RF kick was calculated stand-alone by HFSS, CST MWS and COMSOL codes while the wake kick was calculated by GdfidL. The calculation precision and convergence for both cases are discussed and compared to the results obtained independently by other group.

43 PARTICLE ACCELERATORS↗

Comparison of buffered chemical polished and electropolished 3.9 GHz cavities

Five 3.9 GHz 9 cell cavities have been measured for the DESY FLASH module. These cavities were BCP processed and reached gradients of typically about 25 MV/m with Q drop starting at about 20 MV/m. Recently a few one cell cavities have been processed with EP and at least one has tested to a gradient of 30 MV/m with Q drop starting at about 25 MV/m. We will compare the results and give an update to the thermal analysis in relation to global thermal breakdown at 3.9 GHz.

43 PARTICLE ACCELERATORS↗