Search NASA⌕ Search

Engineering topics

Somerday, Brian P.

Publications and source records attributed to Somerday, Brian P..

Hydrogen-assisted fracture resistance of pipeline welds in gaseous hydrogen

Fracture resistance of pipeline welds from a range of strength grades and welding techniques was measured in air and 21 MPa hydrogen gas, including electric resistance weld of X52, friction stir weld of X100 and gas metal arc welds (GMAW) of X52, X65 and X100. Welds exhibited a decrease in fracture resistance in hydrogen compared to complementary tests in air. A general trend was observed that fracture resistance in 21 MPa hydrogen gas decreased with increasing yield strength. To accommodate material constraints, two different fracture coupon geometries were used in this study, which were shown to yield similar fracture resistance values in air and 21 MPa hydrogen gas; values using different coupons resulted in less than 15% difference. In addition, fracture coupons were removed from controlled locations in select welds to examine the potential influence of orientation and residual stress. The two orientations examined in the X100 GMAW exhibited negligible differences in fracture resistance in air and, similarly, negligible differences in hydrogen. Residual stress exhibited a modest influence on fracture resistance; however, a consistent trend was not observed between tests in air and hydrogen, suggesting further studies are necessary to better understand the influence of residual stress. A comparison of welds and base metals tested in hydrogen gas showed similar susceptibility to hydrogen-assisted fracture. The overall dominant factor in determining the susceptibility to fracture resistance in hydrogen is the yield strength.

08 HYDROGEN↗

On the fatigue crack growth behavior of Ti–10V–2Fe–3Al in gaseous hydrogen

Here, the fatigue crack growth behavior of Ti–10V–2Fe–3Al in gaseous hydrogen (H 2 ) was assessed through comparative experiments conducted in laboratory air and 8.3 MPa H 2 . The measured fatigue crack growth rate (da/dN) versus applied stress intensity factor range (ΔK) relationships and observed fracture morphologies for laboratory air and H 2 were comparable up to ΔK ≈ 6.9 MPa√m, when tested at a load ratio of 0.1 and frequency of 10 Hz. At higher ΔK values, significant crack deflection and subsequent catastrophic failure occurred in the specimen tested in H 2 . This degradation was not observed in a specimen pre-exposed to 8.3 MPa H 2 for 96 h and then immediately tested in laboratory air. X-ray diffraction of the failed H 2 -tested specimen revealed that the material remnants were predominantly composed of TiH 2 , suggesting that hydride formation was the catalyst for catastrophic failure in H 2 . The mechanistic implications of these results and their impact on current material compatibility assessments for Ti alloys in hydrogen service are then discussed.

08 HYDROGEN↗

Stacking Fault Energy Based Alloy Screening for Hydrogen Compatibility

The selection of austenitic stainless steels for hydrogen service is challenging since there are few intrinsic metrics that relate alloy composition to hydrogen degradation. One such metric, explored here, is intrinsic stacking fault energy. Stacking fault energy has an influence on the character and structure of dislocations and on the formation of secondary crystalline phases created during mechanical deformation in austenitic alloys. In this work, a data-driven model for the intrinsic stacking fault energy of common austenitic stainless steel alloys is applied to compare the relative degradation of tensile performance in the presence of hydrogen. A transition in the tensile reduction of area of both 300-series and manganese stabilized stainless steels is observed at a calculated stacking fault energy of approximately 43 mJ m -2 , below which pronounced hydrogen degradation on tensile ductility is observed. The model is also applied to suggest alloying strategies for low nickel austenitic stainless steels for hydrogen service. Lastly, through this investigation, we find that calculated intrinsic stacking fault energy is a high-throughput screening metric that enables the ranking of the performance of a diverse range of austenitic stainless steel compositions, as well as the identification of new alloys, with regard to hydrogen compatibility.

08 HYDROGEN↗