Search NASA⌕ Search

Engineering topics

Son, Jiyoung

Publications and source records attributed to Son, Jiyoung.

At least 19 records

Chemical Imaging for In Situ Detection and Discrimination of Aquatic Toxins Targeting Voltage Gated Sodium Channels

Biologically derived neurotoxins from cyanobacteria and algae impact environmental resources in addition to being considered a potential biological threat to human and animal health. Activity based assays are essential to detecting and responding to toxic neurotoxin events either naturally occurring or deliberate. Two toxins of interest include saxitoxin and brevetoxin. These toxins bind to and alter the function of voltage-gated sodium channels (NaV channels) which are essential for generating cell membrane action potential. We report the development and refinement of a System for Analysis at Liquid Vacuum Interface (SALVI) to assess the functional activity of saxitoxin and brevetoxin. This approach utilizes a vacuum-compatible microfluidic reactor that permits analysis at the liquid vacuum interface of human derived cells with a neurotoxin of interest in a biologically relevant environment.

54 ENVIRONMENTAL SCIENCES↗

SSTDR and FDR Detection of Un-Energized and Energized Cable Anomalies Including Thermal Degradation Using Machine Learning

Historically, cables are initially qualified for nuclear power plant use for 40 years. As plants extend their operating license to 60 and 80 years, continued use of these cables must shift to a performance-based approach since it is cost prohibitive to completely replace cables that are likely still capable of performing their design function. A variety of cable tests are available and are commonly applied during outages when the cables can be taken out of service. Frequency domain reflectometry (FDR) is one of these test methods that is being more broadly accepted and used because it not only detects anomalies along the cable with a low-voltage signal that does not stress the cable insulation, but the technique also locates the anomalies. This supports follow-up local inspection and local repair or partial replacement of a damaged cable segment. Currently, FDR testing is only applied to cables that are taken out of service since the test instrument would be damaged by operational voltages. A related technology that has found some acceptance in the aircraft and rail industry is spread spectrum time domain reflectometry (SSTDR). This technology has been implemented with a custom commercial instrument by LiveWire Innovation that is designed to operate on live cables up to 1000 volts and with a bandwidth of 48 MHz. Initial evaluation by the Pacific Northwest National Laboratory (PNNL) of the Live Wire system indicated that a broader bandwidth (BW) SSTDR may be better for many kinds of flaws. This led PNNL to develop an SSTDR laboratory instrument suitable for tests up to 500 MHz bandwidth. Testing on energized cables is also desirable for online monitoring systems so an inductive clamshell coupler was developed that allows energized cables to be tested up to at least 5 kV and likely higher voltage levels. Dielectric spectroscopy and tan delta testing plus various laboratory destructive tests were included in this data acquisition campaign directed to feed a machine learning (ML) study. With these kinds of developments, online energized cable tests may be possible with industrial adoption of such hardware advances but it will be completely impractical to have highly skilled data analysts continually examine these complex signals for indications of damage or compromised conditions. If online testing is to be implemented in new test hardware, it must be accompanied by software that can interpret the signals and alert plant operators of changing or degraded conditions. The thermally aged, shielded cable investigated here was separately treated for ML analysis. Visual analysis of electrical data showed generally increasing peaks where the cable entered and exited the oven. These peaks were not exactly aligned with expected locations, but these differences were attributed to velocity of propagation calibration errors. Only supervised ML was applied to the thermally aged data as this data was only available shortly before the committed publication date of this report. The supervised ML was structured to divide the 0 to 70-day responses as ‘normal’ from 0 to 35 days or ‘anomalous’ from 36 to 70 days, based on cable tensile elongation at break (EAB) insulation characterization. Using 80% of the data for training and 20% for testing, the supervised ML predicted normal versus anomalous was 70% accurate. Important conclusions include: • Accuracy to predict the presence of cable damage is improved from the 2023 effort by more training data. Weighted accuracies for comparisons among the instruments ranged from 67 to 89 % for unsupervised ML and 71 to 99% for supervised ML. • Based on the synthetic data tests, the unsupervised models are more generalizable to unseen anomalies. The Multi-Layer Perceptron classifier (MLP) model reported as high as 99.7% accuracy on the test data, but this dropped to 58.3% when tested on the synthetic data. In contrast, the unsupervised Pointwise model only achieved 89.7% accuracy on the experimental data but reported 78.3% accuracy on the synthetic data. • The best anomaly indicators are higher frequency (400 MHz BW) FDR data. Other tests may be interesting but for this study, this was the best predicter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Clamshell Current Coupler for Online Frequency Domain and Spread Spectrum Time Domain Reflectometry to Detect Anomalies in Energized Cables

This document describes adaptation and evaluation of a clamshell inductive current coupler for online reflectometry testing (both frequency domain reflectometry and spread spectrum time domain reflectometry) to evaluate cable insulation degradation and anomalies. Safety-critical nuclear power plant cables were initially qualified for 40 years. However, as plants extend their operating licenses to 60 and 80 years, justification for continued safe operation includes test and monitoring programs. These will become more important as the industry moves to condition based qualification programs. Cable test programs traditionally involve manual interventions to disconnect cables, perform one or several tests, then reconnect the systems, usually during refueling outages occurring only every 18 to 24 months. This poses an operational burden that can be minimized by online testing or periodic connection to a coupler that may remain on the cable of interest or be clamped onto the cable without de-termination. This work investigates the adaptation of a clamshell inductive current coupler for either frequency domain reflectometry or spread-spectrum time domain reflectometry. The reflectometry test instrument injects a broad-band chirp or pseudo-noise signal onto a cable conductor and monitors for a reflected signal indicative of an impedance change caused by a damage condition. The instrument maximum input signal levels are typically 10 to 30 volts or less and the instruments will be damaged if subjected to 60 Hz power line voltages of 110, 220, or 480 VAC. One commercial spread-spectrum time domain reflectometry system has circuitry suitable for voltages up to 1 kV, but typical reflectometry tests are performed on de-energized cables. The clamshell inductive coupler provides >60 dB of 60 Hz attenuation with less than 10 dB loss in the 1-500 MHz test bandwidth of interest. An energized cable was successfully tested up to 6.7 kVp-p and frequency response plots imply that the tests could be extended to 10 kV or higher energized levels.

36 MATERIALS SCIENCE↗

SSTDR and FDR Detection of Un-Energized and Energized Cable Anomalies Including Thermal Degradation Using Machine Learning

Historically, cables are initially qualified for nuclear power plant use for 40 years. As plants extend their operating license to 60 and 80 years, continued use of these cables must shift to a performance-based approach since it is cost prohibitive to completely replace cables that are likely still capable of performing their design function. A variety of cable tests are available and are commonly applied during outages when the cables can be taken out of service. Frequency domain reflectometry (FDR) is one of these test methods that is being more broadly accepted and used because it not only detects anomalies along the cable with a low-voltage signal that does not stress the cable insulation, but the technique also locates the anomalies. This supports follow-up local inspection and local repair or partial replacement of a damaged cable segment. Currently, FDR testing is only applied to cables that are taken out of service since the test instrument would be damaged by operational voltages.

36 MATERIALS SCIENCE↗

Spread spectrum time domain reflectometry (SSTDR) and frequency domain reflectometry (FDR) cable inspection using machine learning

Cables are initially qualified for nuclear power plant use for 40 years. As plants extend their operating license to 60 and 80 years, justification for continued cable use must shift to a condition-based approach since it is cost prohibitive to completely replace cables that are likely still capable of performing their design function. The Pacific Northwest National Laboratory (PNNL) Accelerated and Real Time Experimental Nodal Analysis (ARENA) cable motor test bed was used to test the response of a commercial spread spectrum time domain reflectometry (SSTDR) system, a laboratory instrument software-controlled SSTDR, and a vector network analyzer-based frequency domain reflectometry (FDR) system to various cable anomalies. The three instrument systems were able to interrogate cables over a range of frequency bandwidths that can be helpful for human data analysis. Data were subjected to supervised and unsupervised machine learning (ML) analyses to distinguish normal undamaged cable responses from anomalous cable responses. Both supervised and unsupervised ML approaches produced encouraging results with an undamaged/anomalous prediction accuracy from 0.69% to 0.87%. Recommendations for further development and field implementation include increased and more balanced sample sets particularly including more training data.

SSTDR, FDR, Reflectometry, Machine Learning, ARENA↗

ToF-SIMS evaluation of PEG-related mass peaks and applications in PEG detection in cosmetic products

Polyethylene glycols (PEGs) are used in industrial, medical, health care, and personal care applications. The cycling and disposal of synthetic polymers like PEGs pose significant environmental concerns. Detecting and monitoring PEGs in the real world calls for immediate attention. This study unveils the efficacy of time-of-flight secondary ion mass spectrometry (ToF-SIMS) as a reliable approach for precise analysis and identification of reference PEGs and PEGs used in cosmetic products. By comparing SIMS spectra, we show remarkable sensitivity in pinpointing distinctive ion peaks inherent to various PEG compounds. Moreover, the employment of principal component analysis effectively discriminates compositions among different samples. Notably, the application of SIMS two-dimensional image analysis visually portrays the spatial distribution of various PEGs as reference materials. The same is observed in authentic cosmetic products. The application of ToF-SIMS underscores its potential in distinguishing PEGs within intricate environmental context. ToF-SIMS provides an effective solution to studying emerging environmental challenges, offering straightforward sample preparation and superior detection of synthetic organics in mass spectral analysis. These features show that SIMS can serve as a promising alternative for evaluation and assessment of PEGs in terms of the source, emission, and transport of anthropogenic organics.

36 MATERIALS SCIENCE↗

Monitoring of Photovoltaic (PV) Performance and Degradation: Integrated Renewable Energy Systems (IRES) - PV Monitoring Task

The Integrated Renewable Energy System (IRES) testbed demonstration at the Pacific Northwest National Laboratory (PNNL) Sequim campus includes development of a suite of capabilities for tracking the performance of photovoltaic (PV) renewable energy components located on a floating platform (floating PV) and on a shoreline building rooftop. The marine environment represents potentially harsh and corrosive conditions for PV modules. Compared to terrestrial PV, potential concerns for offshore PV arising from high humidity and occasional contact with saltwater, marine wildlife, and aquaculture. These environmental factors can reduce electricity generation efficiency and increase the risk of electrical faults, polymer insulation or jacketing degradation and hydrolysis of the PV cell encapsulant materials. Offshore PV modules may also be exposed to lower temperatures and buoyant and vibrating motions with a floating platform. It is not clear how the long-term performance of floating PV will be affected by these factors. To understand expected energy generation through solar cells on a floating platform, monitoring of the performance of PV modules in the marine environment is needed. This report outlines a plan for long-term testing of IRES PV components utilizing resources of the PNNL Material Aging and Detection (MAaD) Science team and the Marine and Coastal Research Laboratory (MCRL). Equipment applicable for onsite testing and real-time monitoring of the PV performance associated with environmental conditions including temperature, solar irradiance, shading and soiling is included. In case of performance loss, equipment for fault detection, failure analysis, material testing, and further troubleshooting are also available. Through establishment of this capabilities, the enabling IRES project sets the stage for future research to advance off-shore and near-shore energy options for businesses and communities.

14 SOLAR ENERGY↗

Molecular detection of per- and polyfluoroalkyl substances in water using time-of-flight secondary ion mass spectrometry

Detection of per- and polyfluoroalkyl substances (PFASs) is crucial in environmental mitigation and remediation of these persistent pollutants. We demonstrate that time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a viable technique to analyze and identify these substances at parts per trillion (ppt) level in real field samples without complicated sample preparation due to its superior surface sensitivity. Several representative PFAS compounds, such as perfluorooctanesulfonic acid (PFOS), perfluorobutanoic acid (PFBA), perfluoropentanoic acid (PFPeA), perfluoheptanoic acid (PFHpA), and perfluorononanoic acid (PFNA), and real-world groundwater samples collected from monitoring wells installed around at a municipal wastewater treatment plant located in Southern California were analyzed in this work. ToF-SIMS spectral comparison depicts sensitive identification of pseudo-molecular ions, characteristic of reference PFASs. Additionally, principal component analysis (PCA) shows clear discrimination among real samples and reference compounds. Our results show that characteristic molecular ion and fragments peaks can be used to identify PFASs. Furthermore, SIMS two-dimensional (2D) images directly exhibit the distribution of perfluorocarboxylic acid (PFCA) and PFOS in simulated mixtures and real wastewater samples. Such findings indicate that ToF-SIMS is useable to determine PFAS compounds in complex environmental water samples. In conclusion, ToF-SIMS provides simple sample preparation and high sensitivity in mass spectral imaging, offering an alternative solution for environmental forensic analysis of PFASs in wastewater in the future.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spread Spectrum Time Domain Reflectometry (SSTDR) and Frequency Domain Reflectometry (FDR) for Detection of Cable Anomalies Using Machine Learning

Cables are initially qualified for nuclear power plant use for 40 years. As plants extend their operating license to 60 and 80 years, continued use of these cables must shift to a performance-based approach since it is cost prohibitive to completely replace cables that are likely still capable of performing their design function. A variety of cable tests are available and are commonly applied during outages when the cables can be taken out of service. Frequency domain reflectometry (FDR) is one of these test methods that is being more broadly accepted and used because it not only detects anomalies along the cable with a low-voltage signal that does not stress the cable insulation, but the technique also locates the anomalies. This supports follow-up local inspection and local repair or partial replacement of a damaged cable segment. Currently, FDR testing is only applied to cables that are taken out of service since the test instrument would be damaged by operational voltages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extended Bandwidth Spread Spectrum Time Domain Reflectometry Cable Test for Thermal Aging, Low Resistance Fault, and Water Detection

In 2022, researchers at Pacific Northwest National Laboratory (PNNL) used the Accelerated and Real-Time Environmental Nodal Assessment (ARENA) cable and motor test bed to characterize spread spectrum time domain reflectometry (SSTDR) and compare the responses of an SSTDR instrument to those of a frequency domain reflectometry (FDR) instrument. Results showed both techniques could detect and locate cable anomalies such as phase-to-phase low resistance and shorts, thermal insulation damage, mechanical insulation damage, and the presence or absence of water in some conditions. The SSTDR tests used a commercial instrument provided by LiveWire Innovations Inc. This commercial instrument performed tests at 6, 12, 24, and 48 MHz bandwidth. The results of these tests were compared to FDR tests where bandwidths could be extended up to 1.3 GHz, although the best responses for cable tests were from 100 to 500 MHz. Lower bandwidth signals can propagate better along the cable while higher bandwidths have higher resolution for impedance change reflections allowing more precise indication of location and separation of anomalies. The 2022 research found that FDR responses were clearer than SSTDR and speculated that a higher bandwidth SSTDR could more successfully detect and locate cable anomalies. One advantage of the SSTDR system investigated was that it was designed for energized online use up to 1,000 volts, which may be a significant advantage for nuclear power plant use. The LiveWire SSTDR instrument is an established product in the rail and aircraft industry and updating the SSTDR hardware parameters is difficult to justify without more conclusive testing. Therefore, a software adjustable laboratory SSTDR instrument was developed by PNNL and was used to test extended bandwidth SSTDR cable tests. Within the ARENA test bed, 42 cable conditions were tested with the PNNL SSTDR, FDR, and the LiveWire SSTDR—each operating at four different bandwidths. Observations and conclusions regarding the relative performance of the three instruments over different bandwidths are note below. Responses of the PNNL SSTDR (at 50 MHz) and the LiveWire SSTDR (at 48 MHz) were similar. The PNNL SSTDR higher frequency bandwidths behaved as expected showing sharper peaks and higher noise. This validated the PNNL SSTDR as a reasonable implementation of the SSTDR technology. Lower bandwidth SSTDR responses (particularly 6 and 12 MHz) may have increased value for use within longer cables but were not particularly effective at identifying anomalous cable behavior in the 100 ft cables tested here. The higher bandwidths of the PNNL SSTDR (50, 100, 200, and 400 MHz) did not provide substantially clearer cable reflectometry responses, but having the higher frequency responses available did add to the cable test evaluation. Strong responses to shorts and low impedance faults between phases were particularly evident in the higher bandwidth PNNL SSTDR and the FDR data. Measurements were repeatable, with similar responses obtained from a thermally aged cable for tests taken a month apart. Signal noise was affected in the unshielded cable by the local in-tray cable arrangement including proximity to metal edges and rungs of the cable tray. Foam isolation of the cable from the tray metal reduced in both FDR and SSTDR responses. Cable condition monitoring in nuclear power plants will likely benefit from both more informative off-line testing methods and from the development of on-line methods for continuous monitoring of cables in use. The LWRS-funded ARENA test bed was a valuable resource for this development and direct comparison of nuclear electrical cable condition monitoring technologies. Test results are targeted to guide industry advancement of testing and monitoring tools for cable aging management.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Spread Spectrum Time Domain Reflectometry (SSTDR) and Frequency Domain Reflectometry (FDR) for Detection of Cable Anomalies Using Machine Learning

Cables are initially qualified for nuclear power plant use for 40 years. As plants extend their operating license to 60 and 80 years, continued use of these cables must shift to a performance-based approach since it is cost prohibitive to completely replace cables that are likely still capable of performing their design function. A variety of cable tests are available and are commonly applied during outages when the cables can be taken out of service. Frequency domain reflectometry (FDR) is one of these test methods that is being more broadly accepted and used because it not only detects anomalies along the cable with a low-voltage signal that does not stress the cable insulation, but the technique also locates the anomalies. This supports follow-up local inspection and local repair or partial replacement of a damaged cable segment. Currently, FDR testing is only applied to cables that are taken out of service since the test instrument would be damaged by operational voltages. A related technology that has found some acceptance in the aircraft and rail industry is spread spectrum time domain reflectometry (SSTDR). This technology has been implemented with a custom commercial instrument by LiveWire Innovation Inc. that is designed to operate on live cables up to 1000 volts. One of the main conclusions of a previous effort was that cable reflectometry plots can be difficult for humans to analyze due to baseline noise, low or noisy anomaly response peaks, or large responses from cable ends. Detection of cable anomalies for many of these frequencies and test conditions was challenging for manual analysis. This presented an ideal opportunity for ML analysis to distinguish undamaged cable indications from anomalous cable indications. This research discusses application of machine learning (ML) to reflectometry cable test methods. The goal was to assess feasibility to distinguish undamaged cable reflectometry responses from damaged or anomalous cable reflectometry responses. The assessment considered the 3 instruments, multiple frequency bandwidths from each instrument, multiple cable anomalies and test conditions, and both supervised and unsupervised ML approaches. Although approaches and analysis methods were not identical or directly comparable, both outputs were encouraging. The unsupervised prediction weighted accuracy was assessed by instrument and by frequency. It performed better at high frequencies with the highest prediction accuracy of 0.84 for the higher frequency FDR, 0.79 for the 48-MHz LiveWire SSTDR, and 0.77 for 300-MHz PNNL SSTDR. The initial weighted accuracy average across all frequencies for using supervised ML was 0.56 to 0.68. The supervised analysis was repeated with noisier training data removed resulting in weighted accuracies of 0.69 to 0.87. These weighted accuracies are not directly comparable due to differences in the supervised and unsupervised analysis details but do indicate an encouraging trend. Even with limited and unbalanced data, strong prediction accuracies seem encouraging for further work including more data under a wider range of conditions.

42 ENGINEERING↗

Microscale Electrochemical Corrosion of Uranium Oxide Particles

Understanding the corrosion of spent nuclear fuel is important for the development of long-term storage solutions. However, the risk of radiation contamination presents challenges for experimental analysis. Adapted from the system for analysis at the liquid–vacuum interface (SALVI), we developed a miniaturized uranium oxide (UO 2 )-attached working electrode (WE) to reduce contamination risk. To protect UO 2 particles in a miniatured electrochemical cell, a thin layer of Nafion was formed on the surface. Atomic force microscopy (AFM) shows a dense layer of UO 2 particles and indicates their participation in electrochemical reactions. Particles remain intact on the electrode surface with slight redistribution. X-ray photoelectron spectroscopy (XPS) reveals a difference in the distribution of U(IV), U(V), and U(VI) between pristine and corroded UO 2 electrodes. The presence of U(V)/U(VI) on the corroded electrode surface demonstrates that electrochemically driven UO 2 oxidation can be studied using these cells. Our observations of U(V) in the micro-electrode due to the selective semi-permeability of Nafion suggest that interfacial water plays a key role, potentially simulating a water-lean scenario in fuel storage conditions. This novel approach offers analytical reproducibility, design flexibility, a small footprint, and a low irradiation dose, while separating the α-effect. This approach provides a valuable microscale electrochemical platform for spent fuel corrosion studies with minimal radiological materials and the potential for diverse configurations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The ARENA Test Bed – A Versatile Resource for I&C Development and Validation

The Accelerated and Real-time Experimental Nodal Assessment (ARENA) Test Bed at the Pacific Northwest National Laboratory (PNNL) is a versatile resource for development and validation of instrumentation and control (I&C) technologies. This capability was created to facilitate in-situ testing of nuclear electrical cables in various simulated operational environments. Using cable trays, a control box, and selected test components, low voltage cables can be staged to experience local adverse environments such as elevated temperature and water immersion. Cable condition can be continuously monitored over time to track the effect of local stresses using nondestructive assessment tools. A heads-up display (ARENA TV) plots key data in real-time for users. The ARENA Test Bed has recently been used to evaluate the potential for spread spectrum time domain reflectometry (SSTDR) to monitor thermal aging of a portion of live cable powering a three-phase motor. The arrangement provided the opportunity to directly compare the performance of the novel online SSTDR method with offline results from the more standard frequency domain reflectometry (FDR) method. The ability of SSTDR and FDR to identify the presence of water in immersed shielded and unshielded cables and to detect ground faults was also assessed. A digital twin is being developed to track and predict FDR signals from a thermally aging conceptual cable region to compare with measured signals from the ARENA physical counterpart. The test bed concept addresses an important need in nuclear I&C monitoring tool development. New tools and techniques can be developed in the test bed and validated versus known methods and physical measurements. Digital twins and machine learning engines can be populated with measured data in a controlled environment that would not be readily available in the actual nuclear power plant. Proposed monitoring strategies can be confirmed for effectiveness through objective evaluation. It is anticipated that the PNNL ARENA Test Bed will be a valuable resource in advancing nuclear plant instrumentation.

nuclear electrical cables, ARENA Test Bed, conditi↗

Laboratory Instrument Software Controlled Spread Spectrum Time Domain Reflectometry for Electrical Cable Testing

This research discusses development of a software-controlled laboratory instrument based spread spectrum time domain reflectometry system (SSTDR). This constitutes one task within PNNL’s Light Water Sustainability Program (LWRS) whose mission includes advancing nondestructive examination (NDE) techniques for off-line and on-line in-situ cable condition monitoring. In 2022, PNNL evaluated SSTDR for detection and characterization of a number of cable anomalies (Glass et al. 2022). The review included comparison of SSTDR to Frequency Domain Reflectometry (FDR) techniques which have enjoyed encouraging feedback and are starting to be used in nuclear power plants for periodic cable condition monitoring of cable systems as part of the plant’s overall cable aging management program. The FDR test introduces a broad-band chirp onto the cable at the cable end then listens for any reflection from a change of impedance along the cable caused by a damaged conductor or insulation, splices, contact with moisture, or other cable anomalies. The signal is captured in the frequency domain then transformed back to the time domain using an inverse Fourier transform (IFT). Based on the velocity of propagation, the impedance response signal is plotted against distance along the cable. Peak locations along the X-axis indicate the distance along the cable where a portion of the signal has been reflected back to the instrument as a result of a cable anomaly. The FDR test is considered the gold standard of reflectometry however it does require the cable to be de-energized to perform the test. The LIVEWIRE commercial SSTDR produces a similar plot to the FDR however all processing is in the time domain. A pseudo-random noise code (PN code) is input onto the cable conductor and the instrument listens for any reflected response from cable anomalies. The SSTDR processes the signal as an autocorrelation comparing the input PN code to any reflected signal detected. The autocorrelation analysis for thermal aging, water and water ingress detection, ground fault and phase-to-phase fault detection at various locations along the cable and with the cable attached and detached from a motor load, and on both energized and un-energized conditions were performed. These results were contrasted to Frequency Domain Reflectometry (FDR) measurements of the un-energized cable. Results were encouraging but indicated more work was warranted – particularly with the SSTDR, it seemed that the insulation damage would likely be better evaluated with multiple bandwidth cable tests particularly including larger bandwidths than were possible with the current commercial instrument. The commercial instrument’s bandwidth was set at 6, 12, 24, and 48MHz but note that SSTDR and FDR definitions of bandwidth trend similarly but are not the same. The FDR response could be more broadly adjusted, and the bandwidth of 100 to 500 MHz produced the best responses. FDR responses to anomalies were clearer than SSTDR responses and indications were that a broader bandwidth SSTDR may lead to improved SSTDR detection capability. This project used a laboratory instrument based SSTDR (primarily using an Arbitrary Waveform Generator (AWG) and a digital oscilloscope plus Python in-house software) that allowed software adjustment of the SSTDR bandwidth, window functions applied to the exciting Pseudo-random Noise (PN) code plus and other aspects of the SSTDR signal processing. Hereafter, this will be referred to as the PNNL SSTDR. Evaluating specific performance of the PNNL SSTDR is left to a separate report. This report documents hardware and software development to produce the SSTDR cable test system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Revealing the Bacterial Quorum-Sensing Effect on the Biofilm Formation of Diatom Cylindrotheca sp. Using Multimodal Imaging

Diatoms contribute to carbon fixation in the oceans by photosynthesis and always form biofouling organized by extracellular polymeric substances (EPS) in the marine environment. Bacteria-produced quorum-sensing signal molecules N-acyl homoserine lactones (AHLs) were found to play an important role in the development of Cylindrotheca sp. in previous studies, but the EPS composition change was unclear. This study used the technology of alcian blue staining and scanning electron microscopy (SEM), confocal laser scanning microscopy (CLSM), and time-of-flight secondary ion mass spectrometry (ToF-SIMS) to directly observe the biofilm formation process. The results showed that AHLs promote the growth rates of diatoms and the EPS secretion of biofilm components. AHLs facilitated the diatom-biofilm formation by a forming process dependent on the length of carbon chains. AHLs increased the biofilm thickness and the fluorescence intensity and then altered the three-dimensional (3D) structures of the diatom-biofilm. In addition, the enhanced EPS content in the diatom-biofilm testified that AHLs aided biofilm formation. This study provides a collection of new experimental evidence of the interaction between bacteria and microalgae in fouling biofilms.

59 BASIC BIOLOGICAL SCIENCES↗

Studying Cerium Oxide and Uranium Oxide Using Particle Attached Microelectrodes

The conference proceeding presents results of CeO2 and UO2 particles as microelectrodes enclosed in the SALVI E-cell developed in Dr. Yu's lab. These microfluidic cells can be used to study spent fuel materials in minute amount. They offer a flexible and economic way to understand spent fuel oxidation and dissolution in waste storage conditions.

Son, Jiyoung↗