Causes of failure of airship shed

The causes of the collapse of airship shed, which was being taken down at Niediergorsdorf, are discussed. This shed, which was built of iron, was 184 m long, 28 m high, and 35 m wide. The demolition of the shed had been assigned to unskilled men who proceeded to remove certain key structural supports, leaving the structure in such a condition that relatively small eccentricities of the columns or spans or of lateral forces could easily have caused the columns or spans to break down. A small gust of wind would have perhaps sufficed to bring the building down. An analysis is also given of the suction effects on the roof of an air shed in Staaken. The damage to this shed, which occurred during a storm, was due to the fact that the shed had no opening in its top for equalizing the air pressure within and without. The location of the plates blown off the roof correspond to the point of greatest suction.

Sonntag, R↗

Causes of failure of airship sheds

Different causes of airship shed collapse are discussed, with suction and human carelessness being the prime causes.

AIRSHIPS SHEDS - GERMANY↗