Search NASA⌕ Search

Engineering topics

Soong, Y.

Publications and source records attributed to Soong, Y..

PSR J0030+0451 Mass and Radius from NICER Data and Implications for the Properties of Neutron Star Matter

Neutron stars are not only of astrophysical interest, but are also of great interest to nuclear physicists because their attributes can be used to determine the properties of the dense matter in their cores. One of the most informative approaches for determining the equation of state (EoS) of this dense matter is to measure both a star's equatorial circumferential radius R e and its gravitational mass M. Here we report estimates of the mass and radius of the isolated 205.53 Hz millisecond pulsar PSR J0030+0451 obtained using a Bayesian inference approach to analyze its energy-dependent thermal X-ray waveform, which was observed using the Neutron Star Interior Composition Explorer (NICER). This approach is thought to be less subject to systematic errors than other approaches for estimating neutron star radii. We explored a variety of emission patterns on the stellar surface. In this work, our best-fit model has three oval, uniform-temperature emitting spots and provides an excellent description of the pulse waveform observed using NICER. The radius and mass estimates given by this model are ${R}_{e}={13.02}_{-1.06}^{+1.24}$ km and $M={1.44}_{-0.14}^{+0.15}\,{M}_{\odot }$ (68%). The independent analysis reported in the companion paper by Riley et al. explores different emitting spot models, but finds spot shapes and locations and estimates of R e and M that are consistent with those found in this work. We show that our measurements of R e and M for PSR J0030+0451 improve the astrophysical constraints on the EoS of cold, catalyzed matter above nuclear saturation density.

79 ASTRONOMY AND ASTROPHYSICS↗

NICER Observes the Effects of an X-Ray Burst on the Accretion Environment in Aql X-1

Accretion disks around neutron stars regularly undergo sudden strong irradiation by Type I X-raybursts powered by unstable thermonuclear burning on the stellar surface. We investigate the impacton the disk during one of the first X-ray burst observations with the Neutron Star Interior CompositionExplorer (NICER) on the International Space Station. The burst is seen from Aql X-1 during the hardspectral state. In addition to thermal emission from the neutron star, the burst spectrum exhibits anexcess of soft X-ray photons below 1 keV, where NICER's sensitivity peaks. We interpret the excessas a combination of reprocessing by the strongly photoionized disk and enhancement of the pre-burstpersistent flux, possibly due to Poynting Robertson drag or coronal reprocessing. This is the firstsuch detection for a short sub-Eddington burst. As these bursts are observed frequently, NICER willbe able to study how X-ray bursts affect the disk and corona for a range of accreting neutron starsystems and disk states.

Keek, L.↗

The X-Ray Polarimeter Instrument on Board the Polarimeter for Relativistic Astrophysical X-Ray Sources (PRAXyS) Mission

The Polarimeter for Relativistic Astrophysical X-ray Sources (PRAXyS) is one of three Small Explorer (SMEX) missions selected by NASA for Phase A study. The PRAXyS observatory carries an X-ray Polarimeter Instrument (XPI) capable of measuring the linear polarization from a variety of high energy sources, including black holes, neutron stars, and supernova remnants. The XPI is comprised of two identical mirror-Time Projection Chamber (TPC) polarimeter telescopes with a system effective area of 124 sq cm at 3 keV, capable of photon limited observations for sources as faint as 1 mCrab. The XPI is built with well-established technologies. This paper will describe the performance of the XPI flight mirror with the engineering test unit polarimeter

polarization↗

Development of the ASTRO-H Soft X-ray Telescope (SXT): Engineering Model Performance

The X-ray astronomy satellite ASTRO-H, being developed under the collaboration among JAXA, NASA's GSFC and ESA, will have two Soft X-ray Telescopes (SXTs), among other instuments onboard, with a sensitive energy band below 12 keV. One is for an X-ray micorocalorimeter detector and the other for a X-ray CCD detector. The SXT uses a conically approximated Wolter I grazing incidence optic implemented by thin aluminum foil substrates with thickness of 0.152, 0.229, and 0.305 mm. It is similar to the Suzaku XRT, but with larger diameter (45 cm) and longer focal length (5.6 m). Goal of the angular resolution and effective area are 1 arcmin and 390 cm$A2$ at 6 keV, respectively. We made serveral improvements from Suzaku to ASTRO-H, such as thicker substrates, more forming mandrels, thinner epoxy layer for replication, stiffer housings, precise alignment bars, etc. With all these changes, we have fabricated the engineering test unit of the SXT. In this paper, we will discuss all the changes made, their effects, and report X-ray performance of the SXT test unit. An angular resolution of the test unit was measured at new Goddard X-ray calibration facility (100 m X-ray beamline) and was found to be 1.1 arcmin. We will also discuss further improvements toward the flight unit to be delivered to JAXA in 2012.

Okajima, Takashi↗

Production and Performance of the InFOCmicronS 20-40 keV Graded Multilayer Mirror

The International Focusing Optics Collaboration for micron Crab Sensitivity (InFOC micronS) balloon-borne hard x-ray incorporates graded multilayer technology to obtain significant effective area at energies previously inaccessible to x-ray optics. The telescope mirror consists of 2040 segmented thin aluminum foils coated with replicated Pt/C multilayers. A sample of these foils was scanned using a pencil-beam reflectometer to determine, multilayer quality. The results of the reflectometer measurements demonstrate our capability to produce large quantity of foils while maintaining high-quality multilayers with a mean Nevot-Croce interface roughness of 0.5nm. We characterize the performance of the complete InFOC micronS telescope with a pencil beam raster scan to determine the effective area and encircled energy function of the telescope. The effective area of the complete telescope is 78, 42 and 22 square centimeters at 20 30 and 40 keV. respectively. The measured encircled energy fraction of the mirror has a half-power diameter of 2.0 plus or minus 0.5 arcmin (90% confidence). The mirror successfully obtained an image of the accreting black hole Cygnus X-1 during a balloon flight in July, 2001. The successful completion and flight test of this telescope demonstrates that graded-multilayer telescopes can be manufactured with high reliability for future x-ray telescope missions such as Constellation-X.

Berendse, F.↗

Temporal behavior of Hercules X-1 - The long-term variability of its pulse profile and the 35 day X-ray intensity modulation

Data collected by the low-energy detectors of the Hard X-Ray and Low Energy Gamma-Ray Experiment on HEAO 1 were analyzed to study the variability in the temporal behavior of Hercules X-1. Data obtained during thirteen pointed observations distributed in 35-day phase provided details on the time and the energy dependence of the pulse shape and the spectra. It was found that a structural change at the inner edge of the accretion disk, but not at the large radii, was likely to cause the 35-day as well as the observed short-term rapid variations of the pulse profile, which had a considerably more pronounced time dependence than energy dependence. It is suggested that the variable mass-channeling scheme and an intervening effect at the inner accretion disk are directly responsible for the 35-day X-ray modulation.

Soong, Y.↗

Spectral behavior of Hercules X-1 - Its long-term variability and pulse phase spectroscopy

Results are presented of the analysis of the broad-energy-band Her X-1 spectra obtained by HEAO 1. Data from 13 pointed observations covered three 35-day cycles in February, August, and September of 1978. The pulse phase-averaged spectrum did not show any apparent variation during the main-on state, except for the overall intensity. The pulse phase-resolved spectrum, on the other hand, showed a moderately strong phase dependence in each of the main-on state pointings. This may imply that the orientation of the emission region is not changing on a monthly time frame, but the geometry of that region may evolve with time.

Soong, Y.↗

Timing analysis of binary X ray pulsars observed by HEAO 1

Timing analysis of the pointed observations of 5 selected binary X ray pulsars, in two categories of disk-fed and wind-fed sources, by HEAO 1 A-2 is reported. The power spectral analysis was performed on the data in the frequency range from approx. 1 MHz to 6.25 Hz. The coherent signal of the pulsation, the continuum of the power spectrum, varies in time and differs among sources. Quasi-Periodic Oscillation (QPO) is probably related to a fast spinning but weakly magnetized neutron star in the low mass X ray binaries. QPO was searched for in this frequency range to see if scaling laws exist among these two systems which may have possessed different order of magnitude of magnetic field strengths and the inner disk radii. One possible QPO is found centering at 0.062 Hz in 4U0115+63 during a flare.

Soong, Y.↗

Long-term, hard X-ray observations of Scorpius X-1 from HEAO 1

The results of observations of Sco X-1 from three separate scanning epochs during 1977 and 1978 by the UCSD/MIT instruments aboard HEAO 1 in the 15-200 keV range are reported. Intensity and spectral variations have been studied on three time scales: 33-minute scans, daily averages, and weekly averages. No relationship was found between intensity and temperature over the very narrow range of temperatures observed, but comparison of the variability of the intensity, emission measure, and temperature implies at least two different emission mechanisms are at work. It is found that the spectral data are best fitted by either a thin-thermal-bremsstrahlung model of about 5 keV or a Comptonized thermal model of temperature about 3 keV. At higher energies (50-200 keV), no flux is found in excess of the thermal (as claimed by previous observers), and a 2-sigma upper limit from scanning data of 10 to the -5th photons/sq cm sec keV is set. This is an order of magnitude lower than reported detections. Using the distance derived from optical and UV measurements, X-ray luminosities from Sco X-1 incompatible with predictions for spherical accretion onto a white dwarf and emission volumes inconsistent with polar caps of white dwarfs are found.

Soong, Y.↗

A high sensitivity determination of the hard X-ray spectrum of Sco X-1

The results of hard X-ray observations of Sco X-1 by HEAO 1 and OSO 7 are reported. The X-ray spectrum between 20 and 70 keV was found consistent with thermal bremsstrahlung from a hot plasma at a temperature of 5.15 plus or minus 0.05 keV. Observations with the instruments of HEAO 1 on Sept. 6-7, 1978, and with those of OSO 7 during 1972, have not confirmed reports that the bremsstrahlung spectrum is accompanied by an extra component at energies greater than 40 keV - the reported observations yield a two-standard deviation upper limit to the flux in this region of 6.4 x 10 to the -6th photons/sq cm/s/keV.

Rothschild, R. E.↗