Sorg, R. L.

Publications and source records attributed to Sorg, R. L..

High-resolution gray-scale recorder

Electronic circuit makes it possible to obtain gray-scale recordings with good contrast and linearity over entire recording density range for ultrasonic testing unit. Electronic circuit produces square wave of constant voltage but of varying width. Frequency of square-wave pulses can be adjusted to determine optimum pulse frequency.

Moorhead, P. E.

Isometric scan method for ultrasonic evaluation of composite panels

I-scan form of data presentation provides more direct information on nature and severity of flaws present in test specimen and is more easily interpreted by inspector than conventional C-scans currently used. It also offers potential savings in inspection time and cost.

Vary, A.